Literature DB >> 11021698

Unmatched projector/backprojector pairs in an iterative reconstruction algorithm.

G L Zeng1, G T Gullberg.   

Abstract

Computational burden is a major concern when an iterative algorithm is used to reconstruct a three-dimensional (3-D) image with attenuation, detector response, and scatter corrections. Most of the computation time is spent executing the projector and backprojector of an iterative algorithm. Usually, the projector and the backprojector are transposed operators of each other. The projector should model the imaging geometry and physics as accurately as possible. Some researchers have used backprojectors that are computationally less expensive than the projectors to reduce computation time. This paper points out that valid backprojectors should satisfy a condition that the projector/backprojector matrix must not contain negative eigen-values. This paper also investigates the effects when unmatched projector/backprojector pairs are used.

Mesh:

Year:  2000        PMID: 11021698      PMCID: PMC5297459          DOI: 10.1109/42.870265

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  6 in total

1.  Maximum likelihood reconstruction for emission tomography.

Authors:  L A Shepp; Y Vardi
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

2.  Fast implementations of reconstruction-based scatter compensation in fully 3D SPECT image reconstruction.

Authors:  D J Kadrmas; E C Frey; S S Karimi; B M Tsui
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

3.  Implementation of a model-based nonuniform scatter correction scheme for SPECT.

Authors:  A Welch; G T Gullberg
Journal:  IEEE Trans Med Imaging       Date:  1997-12       Impact factor: 10.048

4.  Improving the convergence of iterative filtered backprojection algorithms.

Authors:  D S Lalush; B M Tsui
Journal:  Med Phys       Date:  1994-08       Impact factor: 4.071

5.  Iterative algebraic reconstruction algorithms for emission computed tomography: a unified framework and its application to positron emission tomography.

Authors:  X L Xu; J S Liow; S C Strother
Journal:  Med Phys       Date:  1993 Nov-Dec       Impact factor: 4.071

6.  Dual matrix ordered subsets reconstruction for accelerated 3D scatter compensation in single-photon emission tomography.

Authors:  C Kamphuis; F J Beekman; P P van Rijk; M A Viergever
Journal:  Eur J Nucl Med       Date:  1998-01
  6 in total
  34 in total

1.  Refraction corrected transmission ultrasound computed tomography for application in breast imaging.

Authors:  Shengying Li; Marcel Jackowski; Donald P Dione; Trond Varslot; Lawrence H Staib; Klaus Mueller
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

2.  Convex optimization problem prototyping for image reconstruction in computed tomography with the Chambolle-Pock algorithm.

Authors:  Emil Y Sidky; Jakob H Jørgensen; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2012-04-27       Impact factor: 3.609

3.  Development and evaluation of an improved quantitative (90)Y bremsstrahlung SPECT method.

Authors:  Xing Rong; Yong Du; Michael Ljungberg; Erwann Rault; Stefaan Vandenberghe; Eric C Frey
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

4.  A residual correction method for high-resolution PET reconstruction with application to on-the-fly Monte Carlo based model of positron range.

Authors:  Lin Fu; Jinyi Qi
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

5.  A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging.

Authors:  Hao Yan; Xin Zhen; Michael Folkerts; Yongbao Li; Tinsu Pan; Laura Cervino; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

6.  Accelerated statistical reconstruction for C-arm cone-beam CT using Nesterov's method.

Authors:  Adam S Wang; J Webster Stayman; Yoshito Otake; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

7.  Counter examples for unmatched projector/backprojector in an iterative algorithm.

Authors:  Gengsheng L Zeng
Journal:  Chin J Acad Radiol       Date:  2019-04-11

8.  Accelerating image reconstruction in three-dimensional optoacoustic tomography on graphics processing units.

Authors:  Kun Wang; Chao Huang; Yu-Jiun Kao; Cheng-Ying Chou; Alexander A Oraevsky; Mark A Anastasio
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

9.  Image quality in thoracic 4D cone-beam CT: a sensitivity analysis of respiratory signal, binning method, reconstruction algorithm, and projection angular spacing.

Authors:  Chun-Chien Shieh; John Kipritidis; Ricky T O'Brien; Zdenka Kuncic; Paul J Keall
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

10.  The impact of small motion on the visualization of coronary vessels and lesions in cardiac CT: A simulation study.

Authors:  Francisco Contijoch; J Webster Stayman; Elliot R McVeigh
Journal:  Med Phys       Date:  2017-05-26       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.