Literature DB >> 24819280

Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator.

Yong Du1, Manojeet Bhattacharya, Eric C Frey.   

Abstract

Simultaneous dual-radionuclide myocardial perfusion/innervation SPECT imaging can provide important information about the mismatch between scar tissue and denervated regions. The Siemens IQ-SPECT system developed for cardiac imaging uses a multifocal SMARTZOOM collimator to achieve a four-fold sensitivity for the cardiac region, compared to a typical parallel-hole low-energy high-resolution collimator, but without the data truncation that can result with conventional converging-beam collimators. The increased sensitivity allows shorter image acquisition times or reduced patient dose, making IQ-SPECT ideal for simultaneous dual-radionuclide SPECT, where reduced administrated activity is desirable in order to reduce patient radiation exposure. However, crosstalk is a major factor affecting the image quality in dual-radionuclide imaging. In this work we developed a model-based method that can estimate and compensate for the crosstalk in IQ-SPECT data. The crosstalk model takes into account interactions in the object and collimator-detector system. Scatter in the object was modeled using the effective source scatter estimation technique (ESSE), previously developed to model scatter with parallel-hole collimators. The geometric collimator-detector response was analytically modeled in the IQ-SPECT projector. The estimated crosstalk was then compensated for in an iterative reconstruction process. The new method was validated with data from both Monte Carlo simulations and physical phantom experiments. The results showed that the estimated crosstalk was in good agreement with simulated and measured results. After model-based compensation the images from simultaneous dual-radionuclide acquisitions were similar in quality to those from single-radionuclide acquisitions that did not have crosstalk contamination. The proposed model-based method can be used to improve simultaneous dual-radionuclide images acquired using IQ-SPECT. This work also demonstrates that ESSE scatter modeling can be applied to non-parallel-beam projection geometries.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24819280      PMCID: PMC4142679          DOI: 10.1088/0031-9155/59/11/2813

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  19 in total

1.  Dual-isotope brain SPECT imaging with technetium-99m and iodine-123: validation by phantom studies.

Authors:  M D Devous; J L Lowe; J K Payne
Journal:  J Nucl Med       Date:  1992-11       Impact factor: 10.057

2.  Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function.

Authors:  X Song; W P Segars; Y Du; B M W Tsui; E C Frey
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

3.  Comparison of cardiac sympathetic nervous function with left ventricular function and perfusion in cardiomyopathies by (123)I-MIBG SPECT and (99m)Tc-tetrofosmin electrocardiographically gated SPECT.

Authors:  C Zhao; N Shuke; W Yamamoto; A Okizaki; J Sato; Y Ishikawa; T Ohta; N Hasebe; K Kikuchi; T Aburano
Journal:  J Nucl Med       Date:  2001-07       Impact factor: 10.057

4.  Quantitative evaluation of simultaneous reconstruction with model-based crosstalk compensation for 99mTc/123I dual-isotope simultaneous acquisition brain SPECT.

Authors:  Yong Du; Eric C Frey
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

Review 5.  Development of mIBG as a cardiac innervation imaging agent.

Authors:  David M Raffel; Donald M Wieland
Journal:  JACC Cardiovasc Imaging       Date:  2010-01

6.  Diagnostic accuracy and functional parameters of myocardial perfusion scintigraphy using accelerated cardiac acquisition with IQ SPECT technique in comparison to conventional imaging.

Authors:  Christian Pirich; Peter Keinrath; Gabriele Barth; Gundula Rendl; Lukas Rettenbacher; Margarida Rodrigues
Journal:  Q J Nucl Med Mol Imaging       Date:  2014-06-30       Impact factor: 2.346

7.  Simultaneous technetium-99m/thallium-201 SPECT imaging with model-based compensation for cross-contaminating effects.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  Phys Med Biol       Date:  1999-07       Impact factor: 3.609

8.  Development of a model of the coronary arterial tree for the 4D XCAT phantom.

Authors:  George S K Fung; W Paul Segars; Grant T Gullberg; Benjamin M W Tsui
Journal:  Phys Med Biol       Date:  2011-08-10       Impact factor: 3.609

9.  Application of three-class ROC analysis to task-based image quality assessment of simultaneous dual-isotope myocardial perfusion SPECT (MPS).

Authors:  Xin He; Xiyun Song; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2008-11       Impact factor: 10.048

10.  Mismatch between myocardial accumulation of 123I-MIBG and 99mTc-MIBI and late ventricular potentials in patients after myocardial infarction: association with the development of ventricular arrhythmias.

Authors:  M Yukinaka; M Nomura; S Ito; Y Nakaya
Journal:  Am Heart J       Date:  1998-11       Impact factor: 4.749

View more
  4 in total

1.  Dual-isotope cardiac SPECT: the Twin Peaks Saga in nuclear cardiology.

Authors:  C Marcassa; O Zoccarato
Journal:  J Nucl Cardiol       Date:  2017-04-27       Impact factor: 5.952

2.  Dual isotope and multidetector camera: The best choices for a specific end-point.

Authors:  Roberta Assante; Wanda Acampa
Journal:  J Nucl Cardiol       Date:  2016-05-19       Impact factor: 5.952

3.  Optimization of a simultaneous dual-isotope 201Tl/123I-MIBG myocardial SPECT imaging protocol with a CZT camera for trigger zone assessment after myocardial infarction for routine clinical settings: Are delayed acquisition and scatter correction necessary?

Authors:  Emmanuel D'estanque; Christophe Hedon; Benoît Lattuca; Aurélie Bourdon; Meriem Benkiran; Aurélie Verd; François Roubille; Denis Mariano-Goulart
Journal:  J Nucl Cardiol       Date:  2016-05-25       Impact factor: 5.952

4.  Simultaneous Tc-99m and I-123 dual-radionuclide imaging with a solid-state detector-based brain-SPECT system and energy-based scatter correction.

Authors:  Wataru Takeuchi; Atsuro Suzuki; Tohru Shiga; Naoki Kubo; Yuichi Morimoto; Yuichiro Ueno; Keiji Kobashi; Kikuo Umegaki; Nagara Tamaki
Journal:  EJNMMI Phys       Date:  2016-06-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.