Literature DB >> 20952334

Regularized image reconstruction algorithms for dual-isotope myocardial perfusion SPECT (MPS) imaging using a cross-tracer prior.

Xin He1, Lishui Cheng, Jeffrey A Fessler, Eric C Frey.   

Abstract

In simultaneous dual-isotope myocardial perfusion SPECT (MPS) imaging, data are simultaneously acquired to determine the distributions of two radioactive isotopes. The goal of this work was to develop penalized maximum likelihood (PML) algorithms for a novel cross-tracer prior that exploits the fact that the two images reconstructed from simultaneous dual-isotope MPS projection data are perfectly registered in space. We first formulated the simultaneous dual-isotope MPS reconstruction problem as a joint estimation problem. A cross-tracer prior that couples voxel values on both images was then proposed. We developed an iterative algorithm to reconstruct the MPS images that converges to the maximum a posteriori solution for this prior based on separable surrogate functions. To accelerate the convergence, we developed a fast algorithm for the cross-tracer prior based on the complete data OS-EM (COSEM) framework. The proposed algorithm was compared qualitatively and quantitatively to a single-tracer version of the prior that did not include the cross-tracer term. Quantitative evaluations included comparisons of mean and standard deviation images as well as assessment of image fidelity using the mean square error. We also evaluated the cross tracer prior using a three-class observer study with respect to the three-class MPS diagnostic task, i.e., classifying patients as having either no defect, reversible defect, or fixed defects. For this study, a comparison with conventional ordered subsets-expectation maximization (OS-EM) reconstruction with postfiltering was performed. The comparisons to the single-tracer prior demonstrated similar resolution for areas of the image with large intensity changes and reduced noise in uniform regions. The cross-tracer prior was also superior to the single-tracer version in terms of restoring image fidelity. Results of the three-class observer study showed that the proposed cross-tracer prior and the convergent algorithms improved the image quality of dual-isotope MPS images compared to OS-EM.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20952334      PMCID: PMC3138082          DOI: 10.1109/TMI.2010.2087031

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  13 in total

1.  Fast EM-like methods for maximum "a posteriori" estimates in emission tomography.

Authors:  A R de Pierro; M E Beleza Yamagishi
Journal:  IEEE Trans Med Imaging       Date:  2001-04       Impact factor: 10.048

2.  An accelerated convergent ordered subsets algorithm for emission tomography.

Authors:  Ing-Tsung Hsiao; Anand Rangarajan; Parmeshwar Khurd; Gene Gindi
Journal:  Phys Med Biol       Date:  2004-06-07       Impact factor: 3.609

3.  Regularized image reconstruction algorithms for positron emission tomography.

Authors:  Ji-Ho Chang; John M M Anderson; John R Votaw
Journal:  IEEE Trans Med Imaging       Date:  2004-09       Impact factor: 10.048

4.  Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function.

Authors:  X Song; W P Segars; Y Du; B M W Tsui; E C Frey
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

5.  Convergent incremental optimization transfer algorithms: application to tomography.

Authors:  Sangtae Ahn; Jeffrey A Fessler; Doron Blatt; Alfred O Hero
Journal:  IEEE Trans Med Imaging       Date:  2006-03       Impact factor: 10.048

6.  On the relation between the ISRA and the EM algorithm for positron emission tomography.

Authors:  A R De Pierro
Journal:  IEEE Trans Med Imaging       Date:  1993       Impact factor: 10.048

7.  A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography.

Authors:  A R De Pierro
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

8.  A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography.

Authors:  J Browne; A B de Pierro
Journal:  IEEE Trans Med Imaging       Date:  1996       Impact factor: 10.048

9.  Simultaneous technetium-99m/thallium-201 SPECT imaging with model-based compensation for cross-contaminating effects.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  Phys Med Biol       Date:  1999-07       Impact factor: 3.609

10.  Application of three-class ROC analysis to task-based image quality assessment of simultaneous dual-isotope myocardial perfusion SPECT (MPS).

Authors:  Xin He; Xiyun Song; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2008-11       Impact factor: 10.048

View more
  4 in total

1.  Anatomy-guided brain PET imaging incorporating a joint prior model.

Authors:  Lijun Lu; Jianhua Ma; Qianjin Feng; Wufan Chen; Arman Rahmim
Journal:  Phys Med Biol       Date:  2015-02-16       Impact factor: 3.609

2.  Development and evaluation of convergent and accelerated penalized SPECT image reconstruction methods for improved dose-volume histogram estimation in radiopharmaceutical therapy.

Authors:  Lishui Cheng; Robert F Hobbs; George Sgouros; Eric C Frey
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

3.  Multi-material decomposition using statistical image reconstruction for spectral CT.

Authors:  Yong Long; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-04-25       Impact factor: 10.048

4.  Evaluation of simultaneous 201Tl/99mTc dual-isotope cardiac SPECT imaging with model-based crosstalk compensation using canine studies.

Authors:  Y Du; J M Links; L Becker; A F DiPaula; T Frank; K H Schuleri; A C Lardo; E C Frey
Journal:  J Nucl Cardiol       Date:  2013-12-24       Impact factor: 5.952

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.