Literature DB >> 21317483

Iterative deconvolution of simultaneous 99mTc and 201Tl projection data measured on a CdZnTe-based cardiac SPECT scanner.

Krzysztof Kacperski1, Kjell Erlandsson, Simona Ben-Haim, Brian F Hutton.   

Abstract

We present a method of correcting self-scatter and crosstalk effects in simultaneous technetium-99m/thallium-201 stress/rest myocardial perfusion (single photon emission computed tomography) SPECT scans. The method, which is in essence a hybrid between the triple energy window method and scatter modelling, is based on a model of spatial and spectral distribution of projection counts in several selected energy windows. The parameters of the model are determined from measurements of thin rod sources in air when no in-object scatter or attenuation effects are present. The model equations are solved using the iterative maximum likelihood expectation maximization algorithm in the projection space to find estimates of the primary photopeak counts of both radionuclides. The method has been developed particularly for a novel dedicated cardiac camera based on CdZnTe pixellated detectors, although it can also be adapted to a conventional scintillator camera. The method has been validated in anthropomorphic phantom experiments. Significant improvement in defect contrast has been observed with only moderate increase in image noise. The application of the method to patient data is illustrated.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21317483      PMCID: PMC3111906          DOI: 10.1088/0031-9155/56/5/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  21 in total

1.  Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation.

Authors:  Freek J Beekman; Hugo W A M de Jong; Sander van Geloven
Journal:  IEEE Trans Med Imaging       Date:  2002-08       Impact factor: 10.048

2.  A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera.

Authors:  Sanjiv S Gambhir; Daniel S Berman; Jack Ziffer; Michael Nagler; Martin Sandler; Jim Patton; Brian Hutton; Tali Sharir; Shlomo Ben Haim; Simona Ben Haim
Journal:  J Nucl Med       Date:  2009-04       Impact factor: 10.057

3.  Analysis of the reconstructibility and noise properties of scattered photons in 99mTc SPECT.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  Phys Med Biol       Date:  1997-12       Impact factor: 3.609

4.  Deconvolution of Compton scatter in SPECT.

Authors:  C E Floyd; R J Jaszczak; K L Greer; R E Coleman
Journal:  J Nucl Med       Date:  1985-04       Impact factor: 10.057

5.  Simultaneous thallium-201/technetium-99m dual-isotope cardiac SPECT: ready for prime time?

Authors:  E G DePuey
Journal:  J Nucl Med       Date:  1993-11       Impact factor: 10.057

6.  A new dual-isotope convolution cross-talk correction method: a Tl-201/Tc-99m SPECT cardiac phantom study.

Authors:  K Knesaurek
Journal:  Med Phys       Date:  1994-10       Impact factor: 4.071

7.  Simultaneous technetium-99m/thallium-201 SPECT imaging with model-based compensation for cross-contaminating effects.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  Phys Med Biol       Date:  1999-07       Impact factor: 3.609

Review 8.  Dual-isotope myocardial perfusion SPECT with rest thallium-201 and stress Tc-99m sestamibi.

Authors:  D S Berman; H Kiat; K Van Train; J D Friedman; F P Wang; G Germano
Journal:  Cardiol Clin       Date:  1994-05       Impact factor: 2.213

9.  Simultaneous dual-isotope technetium-99m/thallium-201 cardiac SPET imaging using a projection-dependent spilldown correction factor.

Authors:  G J Hademenos; M Dahlbom; E J Hoffman
Journal:  Eur J Nucl Med       Date:  1995-05

10.  Quantitative simultaneous 99mTc/123I cardiac SPECT using MC-JOSEM.

Authors:  Jinsong Ouyang; Xuping Zhu; Cathryn M Trott; Georges El Fakhri
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

View more
  18 in total

1.  First assessment of simultaneous dual isotope (123I/99mTc) cardiac SPECT on two different CZT cameras: A phantom study.

Authors:  Tanguy Blaire; Alban Bailliez; Fayçal Ben Bouallegue; Dimitri Bellevre; Denis Agostini; Alain Manrique
Journal:  J Nucl Cardiol       Date:  2017-03-08       Impact factor: 5.952

2.  Dual-isotope myocardial perfusion SPECT imaging: Past, present, and future.

Authors:  Tali Sharir; Piotr Slomka
Journal:  J Nucl Cardiol       Date:  2017-06-29       Impact factor: 5.952

3.  Dual isotope and multidetector camera: The best choices for a specific end-point.

Authors:  Roberta Assante; Wanda Acampa
Journal:  J Nucl Cardiol       Date:  2016-05-19       Impact factor: 5.952

4.  Optimization of a simultaneous dual-isotope 201Tl/123I-MIBG myocardial SPECT imaging protocol with a CZT camera for trigger zone assessment after myocardial infarction for routine clinical settings: Are delayed acquisition and scatter correction necessary?

Authors:  Emmanuel D'estanque; Christophe Hedon; Benoît Lattuca; Aurélie Bourdon; Meriem Benkiran; Aurélie Verd; François Roubille; Denis Mariano-Goulart
Journal:  J Nucl Cardiol       Date:  2016-05-25       Impact factor: 5.952

5.  Scatter correction improves concordance in SPECT MPI with a dedicated cardiac SPECT solid-state camera.

Authors:  Amir Pourmoghaddas; Karen Vanderwerf; Terrence D Ruddy; R Glenn Wells
Journal:  J Nucl Cardiol       Date:  2014-10-24       Impact factor: 5.952

6.  Optimization and comparison of simultaneous and separate acquisition protocols for dual isotope myocardial perfusion SPECT.

Authors:  Michael Ghaly; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2015-06-17       Impact factor: 3.609

7.  Low-dose dual-isotope procedure planed for myocardial perfusion CZT-SPECT and assessed through a head-to-head comparison with a conventional single-isotope protocol.

Authors:  Laetitia Imbert; Véronique Roch; Charles Merlin; Wassila Djaballah; Florent Cachin; Mathieu Perrin; Marine Claudin; Antoine Verger; Henri Boutley; Gilles Karcher; Pierre-Yves Marie
Journal:  J Nucl Cardiol       Date:  2017-05-16       Impact factor: 5.952

8.  Evaluation of simultaneous 201Tl/99mTc dual-isotope cardiac SPECT imaging with model-based crosstalk compensation using canine studies.

Authors:  Y Du; J M Links; L Becker; A F DiPaula; T Frank; K H Schuleri; A C Lardo; E C Frey
Journal:  J Nucl Cardiol       Date:  2013-12-24       Impact factor: 5.952

9.  Pitfalls and artifacts using the D-SPECT dedicated cardiac camera.

Authors:  Rayjanah Allie; Brian F Hutton; Elizabeth Prvulovich; Jamshed Bomanji; Sofia Michopoulou; Simona Ben-Haim
Journal:  J Nucl Cardiol       Date:  2015-09-24       Impact factor: 5.952

10.  A preliminary feasibility study of simultaneous dual-isotope imaging with a solid-state dedicated cardiac camera for evaluating myocardial perfusion and fatty acid metabolism.

Authors:  Toshiyuki Ko; Yuko Utanohara; Yasuhiro Suzuki; Makiko Kurihara; Nobuo Iguchi; Jun Umemura; Tetsuya Sumiyoshi; Hitonobu Tomoike
Journal:  Heart Vessels       Date:  2014-09-13       Impact factor: 2.037

View more