Literature DB >> 10452303

Feasibility of simultaneous stress 99mTc-sestamibi/rest 201Tl dual-isotope myocardial perfusion SPECT in the detection of coronary artery disease.

M Nakamura1, K Takeda, T Ichihara, N Motomura, H Shimizu, Y Saito, Y Nomura, N Isaka, T Konishi, T Nakano.   

Abstract

UNLABELLED: This study assesses feasibility and diagnostic accuracy of simultaneous stress 99mTc-sestamibi/rest 201 TI dual-isotope myocardial perfusion SPECT with Moore's correction method, in which contamination originating from lead x-rays produced in a collimator was subtracted in the 201TI windows.
METHODS: Eighty-one patients with suspected coronary artery disease received exercise 99mTc-sestamibi injection, followed by rest 201TI injection 50 min later, and dual-isotope SPECT was performed (group 1). These results were compared with coronary angiographic findings. Furthermore, to estimate the accuracy of Moore's correction method, 201TI crosstalk into the 99mTc acquisition window (group 2A, n = 20) and 99mTc crosstalk into the 201TI acquisition windows (group 2B, n = 20) were studied. For group 2A, stress 99mTc-sestamibi SPECT (single 99mTc-sestamibi SPECT) was performed, followed by 201TI injection at rest and dual-isotope SPECT acquisition 50 min later. For group 2B, rest 201TI SPECT (single 201TI SPECT) was performed, followed by 99mTc-sestamibi injection at rest and dual-isotope SPECT acquisition 30 min later.
RESULTS: Sensitivity and specificity in group 1 were 83% and 99%, respectively, when > or =75% coronary artery narrowing was considered significant. In groups 2A and 2B, SPECT images were divided into 24 segments, and relative regional uptake in each segment was obtained. In group 2A, relative regional uptake of single 99mTc-sestamibi SPECT correlated well with that of dual-isotope SPECT (r = 0.942). In group 2B, relative regional uptake of single 201TI SPECT correlated well with that of dual-isotope SPECT (r = 0.935). Furthermore, in low 201TI uptake segments with relative regional uptake in both single- and dual-isotope SPECT of < or =70%, the degree of concordance between single- and dual-rest 201TI was considered to be high with Bland-Altman analysis and the kappa statistic. Comparison of perfusion defect type demonstrated that, of 22 stress defects within infarct zones, 95% were irreversible and 5% were reversible. In contrast, of 28 stress defects within stenosed vessel zones in noninfarct zones, 89% were reversible and 11% were irreversible (P < 0.0001 versus infarct zones).
CONCLUSION: Simultaneous dual-isotope imaging with Moore's correction method is feasible, with acceptable accuracy for detection of coronary artery disease and a small amount of crosstalk into each window.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10452303

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  9 in total

1.  Navigating beyond the 6th dimension: a challenge in the era of multi-parametric molecular imaging.

Authors:  Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-07       Impact factor: 9.236

2.  Comparison of simultaneous and sequential SPECT imaging for discrimination tasks in assessment of cardiac defects.

Authors:  C M Trott; J Ouyang; G El Fakhri
Journal:  Phys Med Biol       Date:  2010-11-03       Impact factor: 3.609

3.  Preliminary clinical results of photon energy recovery in simultaneous rest Tl-201/stress Tc-99m sestamibi myocardial SPECT.

Authors:  P Hannequin; P Weinmann; J Mas; S Vinot
Journal:  J Nucl Cardiol       Date:  2001 Mar-Apr       Impact factor: 5.952

Review 4.  Multi-modality imaging for the assessment of myocardial perfusion with emphasis on stress perfusion CT and MR imaging.

Authors:  Sung Min Ko; Hweung Kon Hwang; Sung Mok Kim; Ihn Ho Cho
Journal:  Int J Cardiovasc Imaging       Date:  2015-03-26       Impact factor: 2.357

5.  Optimization and comparison of simultaneous and separate acquisition protocols for dual isotope myocardial perfusion SPECT.

Authors:  Michael Ghaly; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2015-06-17       Impact factor: 3.609

6.  Application of three-class ROC analysis to task-based image quality assessment of simultaneous dual-isotope myocardial perfusion SPECT (MPS).

Authors:  Xin He; Xiyun Song; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2008-11       Impact factor: 10.048

7.  Evaluation of simultaneous 201Tl/99mTc dual-isotope cardiac SPECT imaging with model-based crosstalk compensation using canine studies.

Authors:  Y Du; J M Links; L Becker; A F DiPaula; T Frank; K H Schuleri; A C Lardo; E C Frey
Journal:  J Nucl Cardiol       Date:  2013-12-24       Impact factor: 5.952

8.  Intra-patient reproducibility of myocardial SPECT imaging with 201Tl.

Authors:  Barbra E Backus; Frederik A Verburg; R Leo Romijn; Mark W Konijnenberg; Freek J Beekman; J Fred Verzijlbergen
Journal:  J Nucl Cardiol       Date:  2009-01-20       Impact factor: 5.952

9.  Diagnostic value of SPECT, PET and PET/CT in the diagnosis of coronary artery disease: A systematic review.

Authors:  M Al Moudi; Z Sun; N Lenzo
Journal:  Biomed Imaging Interv J       Date:  2011-04-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.