Rapid SPECT simulation of downscatter in non-uniform media.

H W de Jong1, F J Beekman.   

Abstract

A rotation-based Monte Carlo (MC) simulation method (RMC) has been developed, designed for rapid calculation of downscatter through non-uniform media in SPECT. A possible application is downscatter correction in dual isotope SPECT. With RMC, only a fraction of all projections of a SPECT study have to be MC simulated in a standard manner. The other projections can be estimated rapidly using the results of these standard MC calculations. For efficiency, approximations have to be made in RMC with regard to the final scatter angle of the detected photons. Further speed-up is obtained by combining RMC with convolution-based forced detection (CFD) instead of forced detection (FD), which is a more common variance reduction technique for MC. The RMC method was compared with standard MC for 99mTc downscatter in a 201Tl window (72 keV+/-10%) using a digital thorax phantom. The resulting scatter projections are in good agreement (maximum bias a few per cent of the largest value in the projection), but RMC with CFD is about three orders in magnitude faster than standard MC with FD and up to 25 times faster than standard MC with CFD. Using RMC combined with CFD, the generation of 64 almost noise-free downscatter projections (64 x 64) takes only a couple of minutes on a 500 MHz Pentium processor. Therefore, rotation-based Monte Carlo could serve as a practical tool for downscatter correction schemes in dual isotope SPECT.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11277213     DOI: 10.1088/0031-9155/46/3/301

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  Monte Carlo-based down-scatter correction of SPECT attenuation maps.

Authors:  Tomislav Bokulić; Brendan Vastenhouw; Hugo W A M de Jong; Alice J van Dongen; Peter P van Rijk; Freek J Beekman
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-18       Impact factor: 9.236

Review 2.  Scatter modelling and compensation in emission tomography.

Authors:  Habib Zaidi; Kenneth F Koral
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-31       Impact factor: 9.236

3.  Accelerated SPECT Monte Carlo Simulation Using Multiple Projection Sampling and Convolution-Based Forced Detection.

Authors:  Shaoying Liu; Michael A King; Aaron B Brill; Michael G Stabin; Troy H Farncombe
Journal:  IEEE Trans Nucl Sci       Date:  2008-01-01       Impact factor: 1.679

4.  Development and evaluation of a model-based downscatter compensation method for quantitative I-131 SPECT.

Authors:  Na Song; Yong Du; Bin He; Eric C Frey
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

5.  (⁹⁹m)Tc-MAA overestimates the absorbed dose to the lungs in radioembolization: a quantitative evaluation in patients treated with ¹⁶⁶Ho-microspheres.

Authors:  Mattijs Elschot; Johannes F W Nijsen; Marnix G E H Lam; Maarten L J Smits; Jip F Prince; Max A Viergever; Maurice A A J van den Bosch; Bernard A Zonnenberg; Hugo W A M de Jong
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-05-13       Impact factor: 9.236

6.  Fisher information analysis of list-mode SPECT emission data for joint estimation of activity and attenuation distribution.

Authors:  Ashequr Rahman; Yansong Zhu; Eric Clarkson; Matthew A Kupinski; Eric C Frey; Abhinav K Jha
Journal:  Inverse Probl       Date:  2020-08-20       Impact factor: 2.407

7.  Absolute quantitative total-body small-animal SPECT with focusing pinholes.

Authors:  Chao Wu; Frans van der Have; Brendan Vastenhouw; Rudi A J O Dierckx; Anne M J Paans; Freek J Beekman
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-06-25       Impact factor: 9.236

8.  Quantitative simultaneous 99mTc/123I cardiac SPECT using MC-JOSEM.

Authors:  Jinsong Ouyang; Xuping Zhu; Cathryn M Trott; Georges El Fakhri
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

9.  Improved activity estimation with MC-JOSEM versus TEW-JOSEM in 111In SPECT.

Authors:  Jinsong Ouyang; Georges El Fakhri; Stephen C Moore
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

10.  Evaluation of simultaneous 201Tl/99mTc dual-isotope cardiac SPECT imaging with model-based crosstalk compensation using canine studies.

Authors:  Y Du; J M Links; L Becker; A F DiPaula; T Frank; K H Schuleri; A C Lardo; E C Frey
Journal:  J Nucl Cardiol       Date:  2013-12-24       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.