| Literature DB >> 24083664 |
Ho Sik Hwang1, Seh Kwang Park, Man Soo Kim.
Abstract
BACKGROUND: To investigate the biomechanical properties of the cornea measured with the Ocular Response Analyzer (ORA) and their association with the anterior segment parameters representing the geometric dimensions including the corneal volume and anterior chamber volume.Entities:
Mesh:
Year: 2013 PMID: 24083664 PMCID: PMC3852860 DOI: 10.1186/1471-2415-13-49
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Characteristics of the study population (n = 958)
| Age, y | 26.7 ± 6.1 | 18–54 |
| Gender, male | 416 (43.4) | - |
| Female | 542 (56.6) | - |
| Spherical equivalent, D | -4.7 ± 2.2 | -12.1 to +6.5 |
| Mean radius of corneal curvature, mm | 7.76 ± 0.25 | 7.02–9.68 |
| Corneal astigmatism, D | 1.35 ± 0.72 | 0.00–4.40 |
| Central corneal thickness, μm | 536 ± 30 | 428–640 |
| Corneal diameter, mm | 11.5 ± 0.34 | 10.5–13.4 |
| Corneal volume, mm3 | 63.0 ± 3.3 | 53.7– 73.4 |
| Anterior chamber depth, mm | 3.23 ± 0.27 | 2.24–5.24 |
| Anterior chamber volume, mm3 | 192 ± 31 | 103–295 |
| Corneal hysteresis, mmHg | 10.1 ± 1.4 | 7.1–17.2 |
| Corneal resistant factor, mmHg | 9.9 ± 1.6 | 6.2–16.4 |
| IOPg*, mmHg | 14.8 ± 2.6 | 6.4–20.9 |
| IOPcc†, mmHg | 15.8 ± 2.5 | 4.3–20.9 |
*Goldmann correlated intraocular pressure.
†Cornea compensated intraocular pressure.
Figure 1Distribution of corneal hysteresis and corneal resistance factor in Korean.
Linear regression analyses on corneal hysteresis
| | | |||||
|---|---|---|---|---|---|---|
| Age, y | 0.014 | 0.008 | 0.070 | - | ||
| Gender, male | -0.154 | 0.093 | 0.099 | - | ||
| Mean radius of corneal curvature, mm | -0.672 | 0.189 | <0.001 | -0.481 | 0.211 | 0.023 |
| Corneal astigmatism, D | 0.108 | 0.065 | 0.096 | - | ||
| Central corneal thickness, μm | 0.021 | 0.001 | <0.001 | 0.015 | 0.002 | <0.001 |
| Corneal diameter, mm | -0.760 | 0.135 | <0.001 | -0.126 | 0.149 | 0.398 |
| Corneal volume, mm3 | 0.195 | 0.013 | <0.001 | 0.059 | 0.024 | 0.014 |
| Anterior chamber depth, mm | -0.703 | 0.180 | <0.001 | -0.164 | 0.290 | 0.573 |
| Anterior chamber volume, mm3 | -0.009 | 0.002 | <0.001 | -0.004 | 0.003 | 0.180 |
*Adjusted for age and gender.
†Adjusted for mean radius of corneal curvature, central corneal thickness, corneal diameter, corneal volume, anterior chamber depth and anterior chamber volume; adjusted r2 = 0.230.
Linear regression analyses on corneal resistance factor
| Age, y | 0.006 | 0.008 | 0.488 | - | ||
| Gender, male | -0.075 | 0.102 | 0.462 | - | ||
| Mean radius of corneal curvature ,mm | -0.503 | 0.208 | 0.016 | -0.540 | 0.216 | 0.013 |
| Corneal astigmatism, D | 0.098 | 0.071 | 0.166 | - | ||
| Central corneal thickness, μm | 0.029 | 0.001 | <0.001 | 0.026 | 0.003 | <0.001 |
| Corneal diameter, mm | -0.759 | 0.149 | <0.001 | -0.101 | 0.153 | 0.510 |
| Corneal volume, mm3 | 0.239 | 0.013 | <0.001 | 0.029 | 0.025 | 0.244 |
| Anterior chamber depth, mm | -0.767 | 0.197 | <0.001 | -0.234 | 0.298 | 0.433 |
| Anterior chamber volume, mm3 | -0.010 | 0.002 | <0.001 | -0.002 | 0.003 | 0.465 |
*Adjusted for age and gender.
†Adjusted for mean radius of corneal curvature, central corneal thickness, corneal diameter, corneal volume, anterior chamber depth and anterior chamber volume; adjusted r2 = 0.324.
Figure 2Association between corneal hysteresis and corneal volume.