Abstract

PURPOSE: To compare hysteresis, a novel measure of ocular rigidity (viscoelasticity) in normal and keratoconic eyes.
METHODS: The study consisted of 207 normal and 93 keratoconic eyes. Eyes were diagnosed as keratoconic based on clinical examination and corneal topography. The hysteresis was measured by the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY). The data were recorded by Generation 3 software for the ORA. Central corneal thickness (CCT) was measured with a handheld ultrasonic pachymeter in the midpupillary axis.
RESULTS: The mean hysteresis was 10.7 +/- 2.0 (SD) mm Hg (range, 6.1-17.6) in normal eyes compared with 9.6 +/- 2.2 mm Hg (range, 4.7-16.7) in keratoconic eyes. The difference was statistically significant (P < 0.0001, unpaired t-test). Mean CCT in the normal and keratoconic eyes was 545.0 +/- 36.4 microm (range, 471-650) and 491.8 +/- 54.7 microm (range, 341-611), respectively; the difference was significant (P < 0.0001, unpaired t-test).
CONCLUSIONS: Hysteresis was significantly higher in normal than in keratoconic eyes. It may be a useful measurement in addition to CCT, when assessing ocular rigidity, and may be of particular importance when trying to correct intraocular measurements for increased or decreased ocular rigidity. Long-term studies of change in hysteresis may provide information on the progression of keratoconus.

Entities:  

Mesh:

Year:  2007        PMID: 17591868     DOI: 10.1167/iovs.04-0694

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  101 in total

1.  Evaluation of corneal biomechanical properties following penetrating keratoplasty using the ocular response analyzer.

Authors:  Joo Young Shin; Jin Seok Choi; Joo Youn Oh; Mee Kum Kim; Jin Hak Lee; Won Ryang Wee
Journal:  Korean J Ophthalmol       Date:  2010-06-05

2.  Mechanical interferometry imaging for creep modeling of the cornea.

Authors:  Lawrence Yoo; Jason Reed; James K Gimzewski; Joseph L Demer
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-10-28       Impact factor: 4.799

3.  In-vivo corneal biomechanical analysis of unilateral keratoconus.

Authors:  Orhan Ayar; Mehmet Cuneyt Ozmen; Orkun Muftuoglu; Mehmet Orcun Akdemir; Mustafa Koc; Kemal Ozulken
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

4.  [New aspects on biomechanics of the cornea in keratoconus].

Authors:  Z Gatzioufas; B Seitz
Journal:  Ophthalmologe       Date:  2013-09       Impact factor: 1.059

5.  Assessment of corneal properties based on statistical modeling of OCT speckle.

Authors:  Danilo A Jesus; D Robert Iskander
Journal:  Biomed Opt Express       Date:  2016-12-08       Impact factor: 3.732

6.  Optical coherence elastography for evaluating customized riboflavin/UV-A corneal collagen crosslinking.

Authors:  Manmohan Singh; Jiasong Li; Srilatha Vantipalli; Zhaolong Han; Kirill V Larin; Michael D Twa
Journal:  J Biomed Opt       Date:  2017-09-01       Impact factor: 3.170

7.  Discriminant value of custom ocular response analyzer waveform derivatives in keratoconus.

Authors:  Katie M Hallahan; Abhijit Sinha Roy; Renato Ambrosio; Marcella Salomao; William J Dupps
Journal:  Ophthalmology       Date:  2013-11-26       Impact factor: 12.079

8.  Corneal biomechanical properties measured by the ocular response analyzer in acromegalic patients.

Authors:  Emine Sen; Yasemin Tutuncu; Melike Balikoglu-Yilmaz; Ufuk Elgin; Dilek Berker; Faruk Ozturk; Serdar Guler
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-05-13       Impact factor: 3.117

9.  Biomechanical characterization of keratoconus corneas ex vivo with Brillouin microscopy.

Authors:  Giuliano Scarcelli; Sebastien Besner; Roberto Pineda; Seok Hyun Yun
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-06-17       Impact factor: 4.799

10.  Clinical investigation of the effect of topical anesthesia on intraocular pressure.

Authors:  Turki M Almubrad; Kelechi C Ogbuehi
Journal:  Clin Ophthalmol       Date:  2007-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.