Biomechanical properties of the cornea in Fuchs' corneal dystrophy.

María A del Buey1, José A Cristóbal, Francisco J Ascaso, Laura Lavilla, Elena Lanchares.   

Abstract

PURPOSE: To investigate the effects of Fuchs' corneal dystrophy (FCD) on corneal biomechanical properties and the results of IOP readings in relation to changes in corneal hysteresis (CH) and central corneal thickness (CCT).
METHODS: Corneal biomechanical properties, including CH, corneal resistance factor (CRF), and CCT, were measured with the ocular response analyzer (ORA) in 11 eyes of 11 patients with clinically confirmed FCD and 12 eyes of 12 healthy subjects. The ORA was also used to determine the values of intraocular pressure (IOP(g)) and corneal compensated IOP (IOP(cc)). Goldmann applanation tonometry (GAT) was also measured.
RESULTS: CH measured 10.3 +/- 1.6 mm Hg (range, 8.7-13.8) in normal eyes and 6.9 +/- 1.8 mm Hg (range, 4.6-11.7) in FCD eyes (P = 0.001). CRF in the normal and FCD eyes was 10.5 +/- 1.5 mm Hg (range, 8.5-13.3) and 8.1 +/- 1.9 (range, 4.5-11.2), respectively (P = 0.005). CCT was higher in FCD eyes (606 +/- 20 microm; range, 578-635) than in normal eyes (538.4 +/- 24.9 microm; range, 495-575; P = 0.0001). IOP(g) was 16.2 +/- 2.2 mm Hg (range, 13.5-18.7) in control eyes compared with 17.6 +/- 2.7 mm Hg (range, 12.8-18.6) in FCD eyes (P = 0.201). However, IOP(cc) in the FCD group (21.8 +/- 4.6 mm Hg; range, 12.8-29.0) was higher than in the control group (16.5 +/- 3.4 mm Hg; range, 11.9-23.9; P = 0.006). GAT in the normal and FCD eyes was 16.7 +/- 2.1 mm Hg (range, 12.8-18.6) and 16.9 +/- 2.3 mm Hg (range, 13.1-19.0), respectively (P = 0.205).
CONCLUSIONS: FCD led to a change of corneal biomechanical properties. CH and CRF were significantly lower in FCD eyes than in normal eyes. IOP(cc) was significantly higher in FCD eyes than in control eyes. These values may be useful in addition to CCT when assessing corneal rigidity. Thus, FCD may cause an underestimation error in IOP measurement.

Entities:  

Mesh:

Year:  2009        PMID: 19255149     DOI: 10.1167/iovs.08-3312

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  22 in total

1.  Evaluation of corneal biomechanical properties following penetrating keratoplasty using the ocular response analyzer.

Authors:  Joo Young Shin; Jin Seok Choi; Joo Youn Oh; Mee Kum Kim; Jin Hak Lee; Won Ryang Wee
Journal:  Korean J Ophthalmol       Date:  2010-06-05

2.  Corneal biomechanical properties changes after coaxial 2.2-mm microincision and standard 3.0-mm phacoemulsification.

Authors:  Zhe Zhang; Hua Yu; Hui Dong; Li Wang; Ya-Ding Jia; Su-Hua Zhang
Journal:  Int J Ophthalmol       Date:  2016-02-18       Impact factor: 1.779

3.  Comparative analysis of biomechanical parameters of the corneas following Descemet membrane endothelial keratoplasty and contralateral healthy corneas.

Authors:  Natalya F Shilova; Yoav Nahum; Avital Adler; Irit Bahar; Boris E Malyugin; Natalia S Anisimova; Eitan Livny
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-06-11       Impact factor: 3.117

Review 4.  Fuchs endothelial corneal dystrophy.

Authors:  Hussain Elhalis; Behrooz Azizi; Ula V Jurkunas
Journal:  Ocul Surf       Date:  2010-10       Impact factor: 5.033

5.  Does corneal hysteresis correlate with endothelial cell density?

Authors:  Berna Akova-Budak; Sertaç Argun Kıvanç
Journal:  Med Sci Monit       Date:  2015-05-21

6.  Assessment of corneal biomechanical properties and intraocular pressure in myopic spanish healthy population.

Authors:  María A Del Buey; Laura Lavilla; Francisco J Ascaso; Elena Lanchares; Valentín Huerva; José A Cristóbal
Journal:  J Ophthalmol       Date:  2014-02-25       Impact factor: 1.909

Review 7.  Fuchs endothelial corneal dystrophy: The vicious cycle of Fuchs pathogenesis.

Authors:  Stephan Ong Tone; Viridiana Kocaba; Myriam Böhm; Adam Wylegala; Tomas L White; Ula V Jurkunas
Journal:  Prog Retin Eye Res       Date:  2020-05-08       Impact factor: 21.198

8.  Biomechanical parameters of the cornea measured with the Ocular Response Analyzer in normal eyes.

Authors:  Aachal Kotecha; Richard A Russell; Angelos Sinapis; Sayeh Pourjavan; Dimitros Sinapis; David F Garway-Heath
Journal:  BMC Ophthalmol       Date:  2014-01-30       Impact factor: 2.209

Review 9.  Corneal biomechanical properties in different ocular conditions and new measurement techniques.

Authors:  Nery Garcia-Porta; Paulo Fernandes; Antonio Queiros; Jose Salgado-Borges; Manuel Parafita-Mato; Jose Manuel González-Méijome
Journal:  ISRN Ophthalmol       Date:  2014-03-04

10.  The biomechanical properties of the cornea and anterior segment parameters.

Authors:  Ho Sik Hwang; Seh Kwang Park; Man Soo Kim
Journal:  BMC Ophthalmol       Date:  2013-10-02       Impact factor: 2.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.