[Ocular response analyzer: feasibility study and correlation with normal eyes].

R Montard1, R Kopito, O Touzeau, C Allouch, I Letaief, V Borderie, L Laroche.   

Abstract

INTRODUCTION: To evaluate the accuracy of ocular response analyzer (ORA) parameters (corneal hysteresis (CH), corneal resistance factor (CRF), and ocular tension (IOPcc and IOPg)) and the correlation with corneal biometry measured with the Orbscan topographer. MATERIAL: and methods: The Ocular Response Analyzer is a new instrument that measures ocular rigidity/elasticity (CH and CRF) and intraocular pressure (IOPcc), which is assumed to be independent of corneal pachymetry. We compared the results of the ORA in 100 eyes with normal slit lamp examination, except ametropia, with the results from corneal measurements obtained with the Orbscan.
RESULTS: A high correlation and a low difference between the right and left eyes show the accuracy of measurements (rS=0.84, p<0.001 and 8.52%). The mean CH and CRF were 10.25+/-1.6 mmHg (range, 6.5-14.4) and 10.25+/-1.85 mmHg (range, 4.9-14.2), respectively with a Gaussian distribution in normal eyes. The relationship between CH and CRF was significant with corneal pachymetry but not with IOPcc (corneal corrected). CH and CRF were related, although to a lesser extent, with corneal diameter and astigmatism power, but not to keratometry, sex, age, or spherical equivalent.
CONCLUSION: The mean and the distribution of biomechanical factors are similar to the values found in the literature but the relationship to pachymetry seems to be stronger (pachymetry and corneal diameter) than what has been reported in previous publications. The new IOP corrected for the cornea is independent of pachymetry but is not significantly different from Goldmann IOP or IOP measured with a standard noncontact tonometer.

Entities:  

Mesh:

Year:  2007        PMID: 18268436     DOI: 10.1016/s0181-5512(07)79273-2

Source DB:  PubMed          Journal:  J Fr Ophtalmol        ISSN: 0181-5512            Impact factor:   0.818


  8 in total

1.  Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas.

Authors:  Gabor Nemeth; Eszter Szalai; Ziad Hassan; Agnes Lipecz; Zsuzsa Flasko; Laszlo Modis
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779

2.  Corneal Behavior during Tonometer Measurement during the Water Drinking Test in Eyes with XEN GelStent in Comparison to Non-Implanted Eyes.

Authors:  Agnieszka Jóźwik; Joanna Przeździecka-Dołyk; Ewa Wałek; Magdalena Czerniak; Magdalena Asejczyk
Journal:  J Clin Med       Date:  2022-05-24       Impact factor: 4.964

3.  Corneal Biomechanical Changes Following Trabeculectomy, Phaco-trabeculectomy, Ahmed Glaucoma Valve Implantation and Phacoemulsification.

Authors:  Mohammad Pakravan; Mohsen Afroozifar; Shahin Yazdani
Journal:  J Ophthalmic Vis Res       Date:  2014-01

4.  Corneal biomechanics and biomechanically corrected intraocular pressure in primary open-angle glaucoma, ocular hypertension and controls.

Authors:  Riccardo Vinciguerra; Salwah Rehman; Neeru A Vallabh; Mark Batterbury; Gabriela Czanner; Anshoo Choudhary; Robert Cheeseman; Ahmed Elsheikh; Colin E Willoughby
Journal:  Br J Ophthalmol       Date:  2019-03-28       Impact factor: 4.638

5.  The biomechanical properties of the cornea and anterior segment parameters.

Authors:  Ho Sik Hwang; Seh Kwang Park; Man Soo Kim
Journal:  BMC Ophthalmol       Date:  2013-10-02       Impact factor: 2.209

6.  High intercorneal symmetry in corneal biomechanical metrics.

Authors:  XiaoBo Zheng; FangJun Bao; Brendan Geraghty; JinHai Huang; Ayong Yu; QinMei Wang
Journal:  Eye Vis (Lond)       Date:  2016-03-05

7.  Corneal Biomechanical Properties of Keratoconic Eyes Following Penetrating Keratoplasty.

Authors:  Hamidu Gobeka; Özlem Barut Selver; Melis Palamar Onay; Sait Eğrilmez; Ayşe Yağcı
Journal:  Turk J Ophthalmol       Date:  2018-09-04

8.  Relationship between the biomechanical properties of the cornea and anterior segment measurements.

Authors:  Murilo Barreto Souza; Fabricio Witzel de Medeiros; Flavio Fernandes Villela; Milton Ruiz Alves
Journal:  Clinics (Sao Paulo)       Date:  2018-09-21       Impact factor: 2.365

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.