Literature DB >> 17122122

Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer.

Aachal Kotecha1, Ahmed Elsheikh, Cynthia R Roberts, Haogang Zhu, David F Garway-Heath.   

Abstract

PURPOSE: The Ocular Response Analyzer (ORA) is a new instrument that measures the corneal biomechanical response (corneal hysteresis, CH) to rapid indentation by an air jet. CH is the difference in applanation pressures (P1, P2) between the rising and falling phases of the air jet. The investigation had two parts: a characterization study and a validation study. In the characterization study, the purposes were to investigate the intraocular pressure (IOP)-dependence of CH and to characterize the performance of the ORA. In the validation study, the purposes were to investigate the association between CH and both age and central corneal thickness (CCT) and the agreement between ORA and Goldmann applanation tonometer (GAT) IOP measurements.
METHODS: For the characterization study, data were collected from 105 untreated subjects (45 ocular hypertensive patients and 60 normal subjects; mean age, 60 years, range, 26-82). GAT and ORA measurements were performed before and after IOP lowering of one randomly selected eye with apraclonidine drops. The change in P1 and P2 (arbitrary units) in relation to change in GAT IOP was analyzed to calibrate the instrument. The relation between P1, P2, and CCT was explored and ORA IOP was derived from the analyses. For the validation study, ORA and GAT IOP and CCT were measured in 144 eyes of 144 untreated subjects (mean age, 58 years; range, 19-83). The characterization calculations were applied to the dataset and values of CH and ORA IOP were calculated. The relationship between CH and both subject age and CCT was determined. The associations between CH and CCT and between ORA and GAT IOPs, were investigated by linear regression analysis. The agreement between measuring devices was calculated.
RESULTS: In the characterization study, P1 changed by 6.41 arbitrary units for every 1-mm Hg change in GAT IOP. CH (P1 - P2) changed by -1.60 arbitrary units for every 1-mm Hg change in GAT IOP. For each unit change in P2, P1 changed by 1.27 units. From this association a new IOP-independent corneal factor was derived [P1 - (P2/1.27)] and is termed the corneal constant factor (CCF; mm Hg). ORA IOP normalized for CCF was defined as P2 - CCF (mm Hg). The CCF (mm Hg) was associated with CCT (micrometers) and with age: CCF = [(0.036 . CCT) - (0.028 . age)] + 1.06 (adjusted r2 = 0.34; P < 0.0001 for CCT, P = 0.007 for age). Normalized ORA IOP measurements were not associated with CCT. GAT IOP was associated with CCT and CCF-more strongly with the latter: GAT IOP = (0.03 . CCT)+1.52 (r2 = 0.06, P = 0.002); GAT IOP = (0.65 . CCF) + 4.5 (r2 = 0.13, P < 0.0001). The mean difference (95% limits of agreement) between GAT and normalized ORA IOP was 0.1 (-6.6 to +6.8) mm Hg.
CONCLUSIONS: The CCF describes an IOP-independent biomechanical property of the cornea that increases with thicker CCT and decreases with greater age. It is moderately strongly associated with CCT and yet explains more of the interindividual variation in GAT IOP than does CCT. Normalized ORA IOP measurements are not associated with CCT.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17122122     DOI: 10.1167/iovs.06-0557

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  111 in total

1.  Corneal displacement during tonometry with a noncontact tonometer.

Authors:  Yoshiaki Kiuchi; Makoto Kaneko; Hideki Mochizuki; Joji Takenaka; Kenji Yamada; Junko Tanaka
Journal:  Jpn J Ophthalmol       Date:  2012-03-27       Impact factor: 2.447

2.  Mechanical interferometry imaging for creep modeling of the cornea.

Authors:  Lawrence Yoo; Jason Reed; James K Gimzewski; Joseph L Demer
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-10-28       Impact factor: 4.799

3.  Repeatability of intra-ocular pressure and central corneal thickness measurements provided by a non-contact method of tonometry and pachymetry.

Authors:  Domenico Schiano Lomoriello; Marco Lombardo; Laura Tranchina; Francesco Oddone; Sebastiano Serrao; Pietro Ducoli
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-10-28       Impact factor: 3.117

4.  Comparation of the new rebound tonometer IOPen and the Goldmann tonometer, and their relationship to corneal properties.

Authors:  J Moreno-Montañés; I Gosende; J Caire; M García-Granero
Journal:  Eye (Lond)       Date:  2010-10-01       Impact factor: 3.775

5.  The influence of refractive errors on IOP measurement by rebound tonometry (ICare) and Goldmann applanation tonometry.

Authors:  Teresio Avitabile; Antonio Longo; Daniela Rocca; Roberta Amato; Caterina Gagliano; Marine Castaing
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-08-29       Impact factor: 3.117

6.  Intraocular Pressure Measurement Accuracy and Repeatability of a Modified Goldmann Prism: Multicenter Randomized Clinical Trial.

Authors:  Sean McCafferty; Kyle Tetrault; Ann McColgin; Warren Chue; Jason Levine; Melissa Muller
Journal:  Am J Ophthalmol       Date:  2018-09-07       Impact factor: 5.258

7.  Anatomical characterization of central, apical and minimal corneal thickness.

Authors:  Federico Saenz-Frances; Martha Cecilia Bermúdez-Vallecilla; Lara Borrego-Sanz; Luis Jañez; José María Martinez-de-la-Casa; Laura Morales-Fernandez; Enrique Santos-Bueso; Julián Garcia-Sanchez; Julián Garcia-Feijoo
Journal:  Int J Ophthalmol       Date:  2014-08-18       Impact factor: 1.779

8.  Comparison among Ocular Response Analyzer, Corvis ST and Goldmann applanation tonometry in healthy children.

Authors:  Ramin Salouti; Ali Agha Alishiri; Reza Gharebaghi; Mostafa Naderi; Khosrow Jadidi; Ahmad Shojaei-Baghini; Mohammadreza Talebnejad; Zahra Nasiri; Seyedmorteza Hosseini; Fatemeh Heidary
Journal:  Int J Ophthalmol       Date:  2018-08-18       Impact factor: 1.779

Review 9.  Pediatric keratoconus: a review of the literature.

Authors:  Sabrina Mukhtar; Balamurali K Ambati
Journal:  Int Ophthalmol       Date:  2017-08-29       Impact factor: 2.031

10.  Effect of corneal astigmatism on intraocular pressure measurement using ocular response analyzer and Goldmann applanation tonometer.

Authors:  Mana Hagishima; Kazutaka Kamiya; Fusako Fujimura; Tetsuya Morita; Nobuyuki Shoji; Kimiya Shimizu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-09-29       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.