Literature DB >> 18328999

Corneal hysteresis and axial length among Chinese secondary school children: the Xichang Pediatric Refractive Error Study (X-PRES) report no. 4.

Yue Song1, Nathan Congdon, Liping Li, Zhongxia Zhou, Kai Choi, Dennis S C Lam, Chi Pui Pang, Zhenling Xie, Xueyu Liu, Abhishek Sharma, Weihong Chen, Mingzhi Zhang.   

Abstract

PURPOSE: To evaluate the association between corneal hysteresis and axial length/refractive error among rural Chinese secondary school children.
DESIGN: Cross-sectional cohort study.
METHODS: Refractive error (cycloplegic auto-refraction with subjective refinement), central corneal thickness (CCT) and axial length (ultrasonic measurement), intraocular pressure (IOP), and corneal hysteresis (Reichert Ocular Response Analyzer) were measured on a rural school-based cohort of children.
RESULTS: Among 1,233 examined children, the mean age was 14.7 +/- 0.8 years and 699 (56.7%) were girls. The mean spherical equivalent (n = 1,232) was -2.2 +/- 1.6 diopters (D), axial length (n = 643) was 23.7 +/- 1.1 mm, corneal hysteresis (n = 1,153) was 10.7 +/- 1.6 mm Hg, IOP (n = 1,153) was 17.0 +/- 3.4 mm Hg, and CCT (n = 1,226) was 553 +/- 33 microns. In linear regression models, longer axial length was significantly (P < .001 for both) associated with lower corneal hysteresis and higher IOP. Hysteresis in this population was significantly (P < .001) lower than has previously been reported for normal White children (n = 42, 12.3 +/- 1.3 mm Hg), when adjusting for age and gender. This difference did not appear to depend on differences in axial length between the populations, as it persists when only Chinese children with normal uncorrected vision are included.
CONCLUSIONS: Prospective studies will be needed to determine if low hysteresis places eyes at risk for axial elongation secondary or if primary elongation results in lower hysteresis.

Entities:  

Mesh:

Year:  2008        PMID: 18328999     DOI: 10.1016/j.ajo.2007.12.034

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  23 in total

1.  The influence of refractive errors on IOP measurement by rebound tonometry (ICare) and Goldmann applanation tonometry.

Authors:  Teresio Avitabile; Antonio Longo; Daniela Rocca; Roberta Amato; Caterina Gagliano; Marine Castaing
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-08-29       Impact factor: 3.117

2.  Effect of pathological myopia on biomechanical properties: a study by ocular response analyzer.

Authors:  Veysi Öner; Mehmet Taş; Erdal Özkaya; Yavuz Oruç
Journal:  Int J Ophthalmol       Date:  2015-04-18       Impact factor: 1.779

3.  Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas.

Authors:  Gabor Nemeth; Eszter Szalai; Ziad Hassan; Agnes Lipecz; Zsuzsa Flasko; Laszlo Modis
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779

4.  Intraocular pressure and central corneal thickness in the COMET cohort.

Authors:  Karen D Fern; Ruth E Manny; Jane Gwiazda; Leslie Hyman; Katherine Weise; Wendy Marsh-Tootle
Journal:  Optom Vis Sci       Date:  2012-08       Impact factor: 1.973

5.  Investigation of corneal biomechanics at moderate to high refractive errors.

Authors:  Nehir İnceoğlu; Sinan Emre; Mahmut Oğuz Ulusoy
Journal:  Int Ophthalmol       Date:  2017-05-24       Impact factor: 2.031

6.  Association between corneal biomechanical properties and myopia in Chinese subjects.

Authors:  Z Jiang; M Shen; G Mao; D Chen; J Wang; J Qu; F Lu
Journal:  Eye (Lond)       Date:  2011-05-06       Impact factor: 3.775

7.  Keratoconus and normal-tension glaucoma: a study of the possible association with abnormal biomechanical properties as measured by corneal hysteresis (An AOS Thesis).

Authors:  Elisabeth J Cohen
Journal:  Trans Am Ophthalmol Soc       Date:  2009-12

8.  Corneal hysteresis in post-radial keratotomy primary open-angle glaucoma.

Authors:  Joshua S Hardin; Christopher I Lee; Lydia F Lane; Christian C Hester; R Grant Morshedi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-07-23       Impact factor: 3.117

9.  Measurement repeatability of the dynamic Scheimpflug analyzer.

Authors:  Atsuya Miki; Naoyuki Maeda; Tomoko Asai; Yasushi Ikuno; Kohji Nishida
Journal:  Jpn J Ophthalmol       Date:  2017-10-05       Impact factor: 2.447

10.  Normal intraocular pressure in Egyptian children and meta-analysis.

Authors:  Ibrahim Rezkallah Moussa; Rehab Rashad Kassem; Noha Ahmed Edris; Dalia Hamed Khalil
Journal:  Eye (Lond)       Date:  2021-06-18       Impact factor: 4.456

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.