Literature DB >> 23892823

Few-view single photon emission computed tomography (SPECT) reconstruction based on a blurred piecewise constant object model.

Paul A Wolf1, Jakob S Jørgensen, Taly G Schmidt, Emil Y Sidky.   

Abstract

A sparsity-exploiting algorithm intended for few-view single photon emission computed tomography (SPECT) reconstruction is proposed and characterized. The algorithm models the object as piecewise constant subject to a blurring operation. To validate that the algorithm closely approximates the true object in the noiseless case, projection data were generated from an object assuming this model and using the system matrix. Monte Carlo simulations were performed to provide more realistic data of a phantom with varying smoothness across the field of view and a cardiac phantom. Reconstructions were performed across a sweep of two primary design parameters. The results demonstrate that the algorithm recovers the object in a noiseless simulation case. While the algorithm assumes a specific blurring model, the results suggest that the algorithm may provide high reconstruction accuracy even when the object does not match the assumed blurring model. Generally, increased values of the blurring parameter and total variation weighting parameters reduced streaking artifacts, while decreasing spatial resolution. The proposed algorithm demonstrated higher correlation with respect to the true phantom compared to maximum-likelihood expectation maximization (MLEM) reconstructions. Images reconstructed with the proposed algorithm demonstrated reduced streaking artifacts when reconstructing from few views compared to MLEM. The proposed algorithm introduced patchy artifacts in some reconstructed images, depending on the noise level and the selected algorithm parameters. Overall, the results demonstrate preliminary feasibility of a sparsity-exploiting reconstruction algorithm which may be beneficial for few-view SPECT.

Entities:  

Mesh:

Year:  2013        PMID: 23892823      PMCID: PMC3844694          DOI: 10.1088/0031-9155/58/16/5629

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  22 in total

Review 1.  Iterative reconstruction algorithms in nuclear medicine.

Authors:  S Vandenberghe; Y D'Asseler; R Van de Walle ; T Kauppinen; M Koole; L Bouwens; K Van Laere ; I Lemahieu; R A Dierckx
Journal:  Comput Med Imaging Graph       Date:  2001 Mar-Apr       Impact factor: 4.790

2.  FastSPECT II: A Second-Generation High-Resolution Dynamic SPECT Imager.

Authors:  Lars R Furenlid; Donald W Wilson; Yi-Chun Chen; Hyunki Kim; Philip J Pietraski; Michael J Crawford; Harrison H Barrett
Journal:  IEEE Trans Nucl Sci       Date:  2004-06       Impact factor: 1.679

3.  GATE: a simulation toolkit for PET and SPECT.

Authors:  S Jan; G Santin; D Strul; S Staelens; K Assié; D Autret; S Avner; R Barbier; M Bardiès; P M Bloomfield; D Brasse; V Breton; P Bruyndonckx; I Buvat; A F Chatziioannou; Y Choi; Y H Chung; C Comtat; D Donnarieix; L Ferrer; S J Glick; C J Groiselle; D Guez; P F Honore; S Kerhoas-Cavata; A S Kirov; V Kohli; M Koole; M Krieguer; D J van der Laan; F Lamare; G Largeron; C Lartizien; D Lazaro; M C Maas; L Maigne; F Mayet; F Melot; C Merheb; E Pennacchio; J Perez; U Pietrzyk; F R Rannou; M Rey; D R Schaart; C R Schmidtlein; L Simon; T Y Song; J M Vieira; D Visvikis; R Van de Walle; E Wieërs; C Morel
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

4.  Design and simulation of a high-resolution stationary SPECT system for small animals.

Authors:  Freek J Beekman; Brendan Vastenhouw
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

5.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

6.  Improved total variation-based CT image reconstruction applied to clinical data.

Authors:  Ludwig Ritschl; Frank Bergner; Christof Fleischmann; Marc Kachelriess
Journal:  Phys Med Biol       Date:  2011-02-16       Impact factor: 3.609

7.  Correspondence between left ventricular 17 myocardial segments and coronary arteries.

Authors:  Osvaldo Pereztol-Valdés; Jaume Candell-Riera; César Santana-Boado; Juan Angel; Santiago Aguadé-Bruix; Joan Castell-Conesa; Ernest V Garcia; Jordi Soler-Soler
Journal:  Eur Heart J       Date:  2005-09-23       Impact factor: 29.983

8.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

9.  Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms.

Authors:  Jie Tang; Brian E Nett; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2009-09-09       Impact factor: 3.609

10.  The performance of MLEM for dynamic imaging from simulated few-view, multi-pinhole SPECT.

Authors:  Dan Ma; Paul Wolf; Anne V Clough; Taly Gilat Schmidt
Journal:  IEEE Trans Nucl Sci       Date:  2013-02       Impact factor: 1.679

View more
  7 in total

1.  Sparse-view x-ray CT reconstruction via total generalized variation regularization.

Authors:  Shanzhou Niu; Yang Gao; Zhaoying Bian; Jing Huang; Wufan Chen; Gaohang Yu; Zhengrong Liang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2014-05-19       Impact factor: 3.609

2.  On Few-View Tomography and Staircase Artifacts.

Authors:  Gengsheng L Zeng
Journal:  IEEE Trans Nucl Sci       Date:  2015-02-23       Impact factor: 1.679

3.  Optimization-Based Image Reconstruction From Low-Count, List-Mode TOF-PET Data.

Authors:  Zheng Zhang; Sean Rose; Jinghan Ye; Amy E Perkins; Buxin Chen; Chien-Min Kao; Emil Y Sidky; Chi-Hua Tung; Xiaochuan Pan
Journal:  IEEE Trans Biomed Eng       Date:  2018-04       Impact factor: 4.538

4.  An Efficient Augmented Lagrangian Method for Statistical X-Ray CT Image Reconstruction.

Authors:  Jiaojiao Li; Shanzhou Niu; Jing Huang; Zhaoying Bian; Qianjin Feng; Gaohang Yu; Zhengrong Liang; Wufan Chen; Jianhua Ma
Journal:  PLoS One       Date:  2015-10-23       Impact factor: 3.240

5.  Investigation of optimization-based reconstruction with an image-total-variation constraint in PET.

Authors:  Zheng Zhang; Jinghan Ye; Buxin Chen; Amy E Perkins; Sean Rose; Emil Y Sidky; Chien-Min Kao; Dan Xia; Chi-Hua Tung; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2016-07-25       Impact factor: 3.609

6.  Do CNNs Solve the CT Inverse Problem?

Authors:  Emil Y Sidky; Iris Lorente; Jovan G Brankov; Xiaochuan Pan
Journal:  IEEE Trans Biomed Eng       Date:  2021-05-21       Impact factor: 4.756

Review 7.  Virtual clinical trials in medical imaging: a review.

Authors:  Ehsan Abadi; William P Segars; Benjamin M W Tsui; Paul E Kinahan; Nick Bottenus; Alejandro F Frangi; Andrew Maidment; Joseph Lo; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2020-04-11
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.