Literature DB >> 27452653

Investigation of optimization-based reconstruction with an image-total-variation constraint in PET.

Zheng Zhang1, Jinghan Ye, Buxin Chen, Amy E Perkins, Sean Rose, Emil Y Sidky, Chien-Min Kao, Dan Xia, Chi-Hua Tung, Xiaochuan Pan.   

Abstract

Interest remains in reconstruction-algorithm research and development for possible improvement of image quality in current PET imaging and for enabling innovative PET systems to enhance existing, and facilitate new, preclinical and clinical applications. Optimization-based image reconstruction has been demonstrated in recent years of potential utility for CT imaging applications. In this work, we investigate tailoring the optimization-based techniques to image reconstruction for PET systems with standard and non-standard scan configurations. Specifically, given an image-total-variation (TV) constraint, we investigated how the selection of different data divergences and associated parameters impacts the optimization-based reconstruction of PET images. The reconstruction robustness was explored also with respect to different data conditions and activity up-takes of practical relevance. A study was conducted particularly for image reconstruction from data collected by use of a PET configuration with sparsely populated detectors. Overall, the study demonstrates the robustness of the TV-constrained, optimization-based reconstruction for considerably different data conditions in PET imaging, as well as its potential to enable PET configurations with reduced numbers of detectors. Insights gained in the study may be exploited for developing algorithms for PET-image reconstruction and for enabling PET-configuration design of practical usefulness in preclinical and clinical applications.

Entities:  

Mesh:

Year:  2016        PMID: 27452653      PMCID: PMC5062374          DOI: 10.1088/0031-9155/61/16/6055

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  42 in total

1.  Spatiotemporal reconstruction of list-mode PET data.

Authors:  Thomas E Nichols; Jinyi Qi; Evren Asma; Richard M Leahy
Journal:  IEEE Trans Med Imaging       Date:  2002-04       Impact factor: 10.048

2.  Statistical list-mode image reconstruction for the high resolution research tomograph.

Authors:  A Rahmim; M Lenox; A J Reader; C Michel; Z Burbar; T J Ruth; V Sossi
Journal:  Phys Med Biol       Date:  2004-09-21       Impact factor: 3.609

3.  Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images.

Authors:  E U Mumcuoglu; R Leahy; S R Cherry; Z Zhou
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

4.  Noise analysis of MAP-EM algorithms for emission tomography.

Authors:  W Wang; G Gindi
Journal:  Phys Med Biol       Date:  1997-11       Impact factor: 3.609

5.  Analysis of iterative region-of-interest image reconstruction for x-ray computed tomography.

Authors:  Emil Y Sidky; David N Kraemer; Erin G Roth; Christer Ullberg; Ingrid S Reiser; Xiaochuan Pan
Journal:  J Med Imaging (Bellingham)       Date:  2014-10-03

6.  Simultaneous PET and MR imaging.

Authors:  Y Shao; S R Cherry; K Farahani; K Meadors; S Siegel; R W Silverman; P K Marsden
Journal:  Phys Med Biol       Date:  1997-10       Impact factor: 3.609

7.  Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?

Authors:  Xiaochuan Pan; Emil Y Sidky; Michael Vannier
Journal:  Inverse Probl       Date:  2009-01-01       Impact factor: 2.407

8.  Algorithm-enabled exploration of image-quality potential of cone-beam CT in image-guided radiation therapy.

Authors:  Xiao Han; Erik Pearson; Charles Pelizzari; Hania Al-Hallaq; Emil Y Sidky; Junguo Bian; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2015-05-28       Impact factor: 3.609

9.  Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT.

Authors:  Junguo Bian; Jeffrey H Siewerdsen; Xiao Han; Emil Y Sidky; Jerry L Prince; Charles A Pelizzari; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2010-10-20       Impact factor: 3.609

10.  Practical PET Respiratory Motion Correction in Clinical PET/MR.

Authors:  Richard Manber; Kris Thielemans; Brian F Hutton; Anna Barnes; Sébastien Ourselin; Simon Arridge; Celia O'Meara; Simon Wan; David Atkinson
Journal:  J Nucl Med       Date:  2015-05-07       Impact factor: 10.057

View more
  4 in total

1.  Sparse Detector Configuration in SiPM Digital Photon Counting PET: a Feasibility Study.

Authors:  Jun Zhang; Michelle I Knopp; Michael V Knopp
Journal:  Mol Imaging Biol       Date:  2019-06       Impact factor: 3.488

2.  Optimization-Based Image Reconstruction From Low-Count, List-Mode TOF-PET Data.

Authors:  Zheng Zhang; Sean Rose; Jinghan Ye; Amy E Perkins; Buxin Chen; Chien-Min Kao; Emil Y Sidky; Chi-Hua Tung; Xiaochuan Pan
Journal:  IEEE Trans Biomed Eng       Date:  2018-04       Impact factor: 4.538

3.  Directional-TV algorithm for image reconstruction from limited-angular-range data.

Authors:  Zheng Zhang; Buxin Chen; Dan Xia; Emil Y Sidky; Xiaochuan Pan
Journal:  Med Image Anal       Date:  2021-03-05       Impact factor: 8.545

4.  Non-convex primal-dual algorithm for image reconstruction in spectral CT.

Authors:  Buxin Chen; Zheng Zhang; Dan Xia; Emil Y Sidky; Xiaochuan Pan
Journal:  Comput Med Imaging Graph       Date:  2020-12-08       Impact factor: 4.790

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.