The performance of MLEM for dynamic imaging from simulated few-view, multi-pinhole SPECT.

Dan Ma1, Paul Wolf, Anne V Clough, Taly Gilat Schmidt.   

Abstract

Stationary small-animal SPECT systems are being developed for rapid dynamic imaging from limited angular views. This paper quantified, through simulations, the performance of Maximum Likelihood Expectation Maximization (MLEM) for reconstructing a time-activity curve (TAC) with uptake duration of a few seconds from a stationary, three-camera multi-pinhole SPECT system. The study also quantified the benefits of a heuristic method of initializing the reconstruction with a prior image reconstructed from a conventional number of views, for example from data acquired during the late-study portion of the dynamic TAC. We refer to MLEM reconstruction initialized by a prior-image initial guess (IG) as MLEM ig . The effect of the prior-image initial guess on the depiction of contrast between two regions of a static phantom was quantified over a range of angular sampling schemes. A TAC was modeled from the experimentally measured uptake of 99m Tc-hexamethylpropyleneamine oxime (HMPAO) in the rat lung. The resulting time series of simulated images was quantitatively analyzed with respect to the accuracy of the estimated exponential washin and washout parameters. In both static and dynamic phantom studies, the prior-image initial guess improved the spatial depiction of the phantom, for example improved definition of the cylinder boundaries and more accurate quantification of relative contrast between cylinders. For example in the dynamic study, there was ~50% error in relative contrast for MLEM reconstructions compared to ~25-30% error for MLEM ig . In the static phantom study, the benefits of the initial guess decreased as the number of views increased. The prior-image initial guess introduced an additive offset in the reconstructed dynamic images, likely due to biases introduced by the prior image. MLEM initialized with a uniform initial guess yielded images that faithfully reproduced the time dependence of the simulated TAC; there were no statistically significant differences in the mean exponential washin/washout parameters estimated from MLEM reconstructions compared to the true values. Washout parameters estimated from MLEM ig reconstructions did not differ significantly from the true values, however the estimated washin parameter differed significantly from the true value in some cases. Overall, MLEM reconstruction from few views and a uniform initial guess accurately quantified the time dependance of the TAC while introducing errors in the spatial depiction of the object. Initializing the reconstruction with a late-study initial guess improved spatial accuracy while decreasing temporal accuracy in some cases.

Entities:  

Year:  2013        PMID: 24273334      PMCID: PMC3835826          DOI: 10.1109/TNS.2012.2214235

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  30 in total

1.  Performance of the dynamic single photon emission computed tomography (dSPECT) method for decreasing or increasing activity changes.

Authors:  A Celler; T Farncombe; C Bever; D Noll; J Maeght; R Harrop; D Lyster
Journal:  Phys Med Biol       Date:  2000-12       Impact factor: 3.609

2.  SemiSPECT: A Small-animal Imaging System Based on Eight CdZnTe Pixel Detectors.

Authors:  Todd E Peterson; Hyunki Kim; Michael J Crawford; Benjamin M Gershman; William C J Hunter; H Bradford Barber; Lars R Furenlid; Donald W Wilson; James M Woolfenden; Harrison H Barrett
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2002-11-10

3.  Highly constrained backprojection for time-resolved MRI.

Authors:  C A Mistretta; O Wieben; J Velikina; W Block; J Perry; Y Wu; K Johnson; Y Wu
Journal:  Magn Reson Med       Date:  2006-01       Impact factor: 4.668

4.  A multipinhole small animal SPECT system with submillimeter spatial resolution.

Authors:  Tobias Funk; Philippe Després; William C Barber; Kanai S Shah; Bruce H Hasegawa
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

5.  Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals.

Authors:  Andrew B Hwang; Benjamin L Franc; Grant T Gullberg; Bruce H Hasegawa
Journal:  Phys Med Biol       Date:  2008-04-09       Impact factor: 3.609

6.  Effect of overlapping projections on reconstruction image quality in multipinhole SPECT.

Authors:  Kathleen Vunckx; Paul Suetens; Johan Nuyts
Journal:  IEEE Trans Med Imaging       Date:  2008       Impact factor: 10.048

7.  Quantitative analysis of acute myocardial infarct in rat hearts with ischemia-reperfusion using a high-resolution stationary SPECT system.

Authors:  Zhonglin Liu; George A Kastis; Gail D Stevenson; Harrison H Barrett; Lars R Furenlid; Matthew A Kupinski; Dennis D Patton; Donald W Wilson
Journal:  J Nucl Med       Date:  2002-07       Impact factor: 10.057

8.  Kinetic behavior of technetium-99m-HMPAO in the human brain and quantification of cerebral blood flow using dynamic SPECT.

Authors:  K Murase; S Tanada; H Fujita; S Sakaki; K Hamamoto
Journal:  J Nucl Med       Date:  1992-01       Impact factor: 10.057

9.  Imaging recognition of multidrug resistance in human breast tumors using 99mTc-labeled monocationic agents and a high-resolution stationary SPECT system.

Authors:  Zhonglin Liu; Gail D Stevenson; Harrison H Barrett; George A Kastis; Michael Bettan; Lars R Furenlid; Donald W Wilson; James M Woolfenden
Journal:  Nucl Med Biol       Date:  2004-01       Impact factor: 2.408

10.  Technetium-99m HM-PAO stereoisomers as potential agents for imaging regional cerebral blood flow: human volunteer studies.

Authors:  P F Sharp; F W Smith; H G Gemmell; D Lyall; N T Evans; D Gvozdanovic; J Davidson; D A Tyrrell; R D Pickett; R D Neirinckx
Journal:  J Nucl Med       Date:  1986-02       Impact factor: 10.057

View more
  2 in total

1.  Image reconstruction in fluorescence molecular tomography with sparsity-initialized maximum-likelihood expectation maximization.

Authors:  Yansong Zhu; Abhinav K Jha; Dean F Wong; Arman Rahmim
Journal:  Biomed Opt Express       Date:  2018-06-13       Impact factor: 3.732

2.  Few-view single photon emission computed tomography (SPECT) reconstruction based on a blurred piecewise constant object model.

Authors:  Paul A Wolf; Jakob S Jørgensen; Taly G Schmidt; Emil Y Sidky
Journal:  Phys Med Biol       Date:  2013-07-29       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.