Literature DB >> 26495975

An Efficient Augmented Lagrangian Method for Statistical X-Ray CT Image Reconstruction.

Jiaojiao Li1, Shanzhou Niu2, Jing Huang1, Zhaoying Bian1, Qianjin Feng1, Gaohang Yu2, Zhengrong Liang3, Wufan Chen1, Jianhua Ma1.   

Abstract

Statistical iterative reconstruction (SIR) for X-ray computed tomography (CT) under the penalized weighted least-squares criteria can yield significant gains over conventional analytical reconstruction from the noisy measurement. However, due to the nonlinear expression of the objective function, most exiting algorithms related to the SIR unavoidably suffer from heavy computation load and slow convergence rate, especially when an edge-preserving or sparsity-based penalty or regularization is incorporated. In this work, to address abovementioned issues of the general algorithms related to the SIR, we propose an adaptive nonmonotone alternating direction algorithm in the framework of augmented Lagrangian multiplier method, which is termed as "ALM-ANAD". The algorithm effectively combines an alternating direction technique with an adaptive nonmonotone line search to minimize the augmented Lagrangian function at each iteration. To evaluate the present ALM-ANAD algorithm, both qualitative and quantitative studies were conducted by using digital and physical phantoms. Experimental results show that the present ALM-ANAD algorithm can achieve noticeable gains over the classical nonlinear conjugate gradient algorithm and state-of-the-art split Bregman algorithm in terms of noise reduction, contrast-to-noise ratio, convergence rate, and universal quality index metrics.

Entities:  

Mesh:

Year:  2015        PMID: 26495975      PMCID: PMC4619856          DOI: 10.1371/journal.pone.0140579

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


  19 in total

1.  Generalized Gibbs priors based positron emission tomography reconstruction.

Authors:  Jianhua Ma; Qianjin Feng; Yanqiu Feng; Jing Huang; Wufan Chen
Journal:  Comput Biol Med       Date:  2010-05-05       Impact factor: 4.589

2.  Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

3.  Parallel MR image reconstruction using augmented Lagrangian methods.

Authors:  Sathish Ramani; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2010-11-18       Impact factor: 10.048

4.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

5.  Inverse determination of the penalty parameter in penalized weighted least-squares algorithm for noise reduction of low-dose CBCT.

Authors:  Jing Wang; Huaiqun Guan; Timothy Solberg
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

6.  Noise correlation in CBCT projection data and its application for noise reduction in low-dose CBCT.

Authors:  Hua Zhang; Luo Ouyang; Jianhua Ma; Jing Huang; Wufan Chen; Jing Wang
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

7.  A splitting-based iterative algorithm for accelerated statistical X-ray CT reconstruction.

Authors:  Sathish Ramani; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2011-11-08       Impact factor: 10.048

8.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

9.  Few-view single photon emission computed tomography (SPECT) reconstruction based on a blurred piecewise constant object model.

Authors:  Paul A Wolf; Jakob S Jørgensen; Taly G Schmidt; Emil Y Sidky
Journal:  Phys Med Biol       Date:  2013-07-29       Impact factor: 3.609

10.  Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms.

Authors:  Jie Tang; Brian E Nett; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2009-09-09       Impact factor: 3.609

View more
  3 in total

1.  [Total generalized variation minimization based on projection data for low?dose CT reconstruction].

Authors:  Shan-Zhou Niu; Heng Wu; Ze-Feng Yu; Zi-Jun Zheng; Gao-Hang Yu
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2017-12-20

2.  Nonlocal low-rank and sparse matrix decomposition for spectral CT reconstruction.

Authors:  Shanzhou Niu; Gaohang Yu; Jianhua Ma; Jing Wang
Journal:  Inverse Probl       Date:  2018-01-10       Impact factor: 2.407

3.  Fast alternating projection methods for constrained tomographic reconstruction.

Authors:  Li Liu; Yongxin Han; Mingwu Jin
Journal:  PLoS One       Date:  2017-03-02       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.