Literature DB >> 22648556

A new method of measuring acetabular cup anteversion on simulated radiographs.

Vikas Bachhal1, Nipun Jindal, Gaurav Saini, Radheshyam Sament, Vishal Kumar, Devendra Chouhan, Mandeep Dhillon.   

Abstract

PURPOSE: Optimal positioning of acetabular components is crucial for maintaining stability of THA. Postoperative assessment of acetabular anteversion is a vital but difficult task. Various methods have been devised with good results for measuring anteversion on plain radiographs but these methods are either too complicated or require special objects like scientific calculators, special protectors, tables, etc. A new simplified method of measuring anteversion on plain radiographs was created based on basic geometry.
METHODS: Anteversion of acetabular components was estimated on computer generated images of the acetabular cup by our method and compared with two previously established methods of Liaw and Pradhan. Measurement was done at 400 different positions of acetabular cup and compared with actual values. Another analysis was done after adding the femoral head to the acetabular component, thus obscuring some of the acetabular rim.
RESULTS: Mean and standard deviation of error for our method was 0.77° ± 0.75° as compared to 0.93° ± 0.86° and 0.72° ± 0.68° for the methods of Liaw and Pardhan, respectively, with no significant differences from actual values. Maximal errors for our method, Liaw's and Pradhan's method were 3°, 4°, and 2.91°, respectively. On analysis, after the adding femoral head, there was a significant error of measurement with Liaw's method, while our method as well as Pardhan's remained accurate. All methods showed high inter- and intraobserver reliability.
CONCLUSION: Our new simplified method of measuring acetabular anteversion on plain radiographs is acceptable in comparision to other established methods and requires only routinely used goniometer and calliper.

Entities:  

Mesh:

Year:  2012        PMID: 22648556      PMCID: PMC3427440          DOI: 10.1007/s00264-012-1583-9

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  18 in total

1.  A method to measure acetabular cup anteversion after total hip replacement.

Authors:  L Fabeck; D Farrokh; M Tolley; P Y Descamps; M Gebhart; P Delincé
Journal:  Acta Orthop Belg       Date:  1999-12       Impact factor: 0.500

2.  Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs.

Authors:  R Pradhan
Journal:  J Bone Joint Surg Br       Date:  1999-05

3.  Evaluation of acetabular anteversion following total hip arthroplasty: necessity of proper centring.

Authors:  T G Goergen; D Resnick
Journal:  Br J Radiol       Date:  1975-04       Impact factor: 3.039

4.  A simplified method to determine acetabular cup anteversion from plain radiographs.

Authors:  Karl-Heinz Widmer
Journal:  J Arthroplasty       Date:  2004-04       Impact factor: 4.757

5.  Measurement of the acetabular cup anteversion on simulated radiographs.

Authors:  Chen-Kun Liaw; Rong-Sen Yang; Sheng-Mou Hou; Tai-Yin Wu; Chiou-Shann Fuh
Journal:  J Arthroplasty       Date:  2008-04-03       Impact factor: 4.757

6.  Anteversion of the acetabular cup. Measurement of angle after total hip replacement.

Authors:  M K Ackland; W B Bourne; H K Uhthoff
Journal:  J Bone Joint Surg Br       Date:  1986-05

7.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

8.  A new method for measuring angles after total hip arthroplasty. A study of the acetabular cup and femoral component.

Authors:  J D Visser; J G Konings
Journal:  J Bone Joint Surg Br       Date:  1981

9.  Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis.

Authors:  B M Jolles; P Zangger; P-F Leyvraz
Journal:  J Arthroplasty       Date:  2002-04       Impact factor: 4.757

10.  A new CT method for measuring cup orientation after total hip arthroplasty: a study of 10 patients.

Authors:  Henrik Olivecrona; Lars Weidenhielm; Lotta Olivecrona; Mats O Beckman; André Stark; Marilyn E Noz; Gerald Q Maguire; Michael P Zeleznik; Lars Svensson; Torbjörn Jonson
Journal:  Acta Orthop Scand       Date:  2004-06
View more
  17 in total

1.  What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component Position.

Authors:  Matthew P Abdel; Philipp von Roth; Matthew T Jennings; Arlen D Hanssen; Mark W Pagnano
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

2.  Accuracy of plain antero-posterior radiographic-based methods for measurement of acetabular cup version.

Authors:  Mohammad Ali Alzohiry; Mohammad Kamal Abdelnasser; Mohamed Moustafa; Mohamed Mahran; Hatem Bakr; Yaser Khalifa; Ahmed Abelaal; Haisam Atta; Galal Zaki Said
Journal:  Int Orthop       Date:  2018-06-04       Impact factor: 3.075

Review 3.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

4.  Use of a novel imageless navigation system reduced fluoroscopy exposure and improved acetabular positioning in anterior approach total hip arthroplasty: a case-control study.

Authors:  Christian B Ong; Yu-Fen Chiu; Ajay Premkumar; Alejandro Gonzalez Della Valle
Journal:  Arch Orthop Trauma Surg       Date:  2022-07-01       Impact factor: 3.067

5.  Lumbar spinal fusion does not increase early dislocation risk in primary total hip arthroplasty through the direct anterior approach.

Authors:  Dimitris Dimitriou; Christoph Zindel; Sabrina Weber; Dominik Kaiser; Michael Betz; Mazda Farshad
Journal:  Arch Orthop Trauma Surg       Date:  2021-10-13       Impact factor: 2.928

6.  Experimental study of the installation acetabular component with uncoverage in arthroplasty patients with severe developmental hip dysplasia.

Authors:  Rashid Tikhilov; Igor Shubnyakov; Scott Burns; Nikolay Shabrov; Alexey Kuzin; Andrey Mazurenko; Alexey Denisov
Journal:  Int Orthop       Date:  2015-08-09       Impact factor: 3.075

7.  Acetabular positioning is more consistent with the use of a novel miniature computer-assisted device.

Authors:  Ivan Jacob; Jessica Benson; Kate Shanaghan; Alejandro Gonzalez Della Valle
Journal:  Int Orthop       Date:  2020-01-22       Impact factor: 3.075

8.  GeoGebra: A reliable and free software for measuring acetabular cup anteversion on digitalized plain radiographs.

Authors:  Vikas Bachhal; Gaurav Saini; Nipun Jindal; Radheshyam Sament; Ankit Dadra
Journal:  J Clin Orthop Trauma       Date:  2020-02-05

9.  Intra-operative referencing technique is non-inferior to use of fluoroscopy for acetabular component positioning in anterior hip arthroplasty.

Authors:  Spencer Summers; Justin Ocksrider; Bradley Lezak; Erik C Zachwieja; Michaela Maria Schneiderbauer
Journal:  J Clin Orthop Trauma       Date:  2020-10-20

10.  A Novel Method for Correcting Pelvic Tilt on Anteroposterior Pelvic Radiographs.

Authors:  Jeffrey M Muir; John Vincent; Joseph Schipper; Varsha D Gobin; Meinusha Govindarajan; Karlina Fiaes; Jonathan Vigdorchik
Journal:  Cureus       Date:  2019-12-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.