Literature DB >> 33717920

Intra-operative referencing technique is non-inferior to use of fluoroscopy for acetabular component positioning in anterior hip arthroplasty.

Spencer Summers1, Justin Ocksrider1, Bradley Lezak2, Erik C Zachwieja1, Michaela Maria Schneiderbauer3.   

Abstract

BACKGROUND: Intra-operative fluoroscopy has been shown to improve the accuracy of acetabular component positioning when compared to no fluoroscopy in direct anterior approach (DAA) total hip arthroplasty (THA). Due to logistical reasons, our senior author has been performing DAA THA at one institution without the use of fluoroscopy and has created an intraoperative referencing technique to aid in acetabular component positioning. The purpose of this study is to evaluate the accuracy of acetabular component positioning using fluoroscopy when compared to an intra-operative referencing technique without fluoroscopy.
METHODS: A total of 214 consecutive primary DAA THA were performed by one surgeon at two institutions and were retrospectively reviewed over a 3-year period. Intra-operative fluoroscopy was used with all patients at Institution A (N = 154). At institution B (N = 60), no fluoroscopy was used, and an intra-operative referencing technique was employed to assist in placement of the acetabular component.
RESULTS: In the fluoroscopy group, 91% of components met our abduction target, 90% met our anteversion target, and 82.5% simultaneously met both targets. In the non-fluoroscopy group, 98% of components met our abduction target, 92% met our anteversion target, and 90% simultaneously met both targets. There was no difference between groups for placement of the component within both targets simultaneously (p = .171).
CONCLUSION: Use of our intra-operative referencing technique is non-inferior in placing acetabular components within a pre-defined safe zone when compared to use of intraoperative fluoroscopy. The intra-operative reference technique can be a helpful adjunct for ensuring accurate acetabular component positioning while simultaneously reducing cost and limiting radiation exposure.
© 2020 Delhi Orthopedic Association. All rights reserved.

Entities:  

Keywords:  Acetabular component positioning; Direct anterior approach; Fluoroscopy; Total hip arthroplasty

Year:  2020        PMID: 33717920      PMCID: PMC7920138          DOI: 10.1016/j.jcot.2020.10.032

Source DB:  PubMed          Journal:  J Clin Orthop Trauma        ISSN: 0976-5662


  18 in total

1.  A new method of measuring acetabular cup anteversion on simulated radiographs.

Authors:  Vikas Bachhal; Nipun Jindal; Gaurav Saini; Radheshyam Sament; Vishal Kumar; Devendra Chouhan; Mandeep Dhillon
Journal:  Int Orthop       Date:  2012-05-31       Impact factor: 3.075

2.  Accuracy and potential pitfalls of fluoroscopy-guided acetabular cup placement.

Authors:  Moritz Tannast; Frank Langlotz; Monika Kubiak-Langer; Ulrich Langlotz; Klaus-Arno Siebenrock
Journal:  Comput Aided Surg       Date:  2005 Sep-Nov

3.  Does intraoperative fluoroscopy improve component positioning in total hip arthroplasty?

Authors:  Eric H Tischler; Fabio Orozco; Vinay K Aggarwal; Haroldo Pacheco; Zachary Post; Alvin Ong
Journal:  Orthopedics       Date:  2015-01       Impact factor: 1.390

Review 4.  Radiation Exposure and Health Risks for Orthopaedic Surgeons.

Authors:  Roman A Hayda; Raymond Y Hsu; J Mason DePasse; Joseph A Gil
Journal:  J Am Acad Orthop Surg       Date:  2018-04-15       Impact factor: 3.020

5.  Increased cancer risk among surgeons in an orthopaedic hospital.

Authors:  Giuseppe Mastrangelo; Ugo Fedeli; Emanuela Fadda; Angelo Giovanazzi; Luca Scoizzato; Bruno Saia
Journal:  Occup Med (Lond)       Date:  2005-09       Impact factor: 1.611

6.  Patient Radiation Exposure During Fluoro-Assisted Direct Anterior Approach Total Hip Arthroplasty.

Authors:  Brian M Curtin; Lucas C Armstrong; Brandon T Bucker; Susan M Odum; William A Jiranek
Journal:  J Arthroplasty       Date:  2015-12-17       Impact factor: 4.757

7.  Radiation Exposure During Fluoro-Assisted Direct Anterior Total Hip Arthroplasty.

Authors:  Christopher L Pomeroy; J Bohannon Mason; Thomas K Fehring; John L Masonis; Brian M Curtin
Journal:  J Arthroplasty       Date:  2016-01-29       Impact factor: 4.757

8.  Accuracy of acetabular component position in hip arthroplasty.

Authors:  Robert L Barrack; Jeffrey A Krempec; John C Clohisy; Douglas J McDonald; William M Ricci; Erin L Ruh; Ryan M Nunley
Journal:  J Bone Joint Surg Am       Date:  2013-10-02       Impact factor: 5.284

9.  Prospective Assessment of the Oncogenic Risk to Patients From Fluoroscopy During Trauma Surgery.

Authors:  Michael J Beebe; Peter Jenkins; David L Rothberg; Erik N Kubiak; Thomas F Higgins
Journal:  J Orthop Trauma       Date:  2016-07       Impact factor: 2.512

10.  Direct Anterior Total Hip Arthroplasty.

Authors:  Patrick F Bergin; Anthony S Unger
Journal:  JBJS Essent Surg Tech       Date:  2011-10-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.