Literature DB >> 1153755

Visual detection and localization of radiographic images.

S J Starr, C E Metz, L B Lusted, D J Goodenough.   

Abstract

In conventional receiver-operating-characteristic (ROC) curve analysis of visual detection performance, the observer is credited with a true-positive response if a visual signal is present somewhere in a radiograph called "positive" by the observer; however, the measured true-positive rate can be different for a given false-positive rate if the observer is required to identify the correct location of the visual signal in order to receive credit for a true-positive response. The authors describe and have confirmed experimentally a model which can be used to predict observer performance in an experiment requiring both detection and localization on the basis of the conventional ROC curve determined in a detection experiment. Implications for the use of signal detection theory in the assessment of radiographic image quality are discussed.

Mesh:

Year:  1975        PMID: 1153755     DOI: 10.1148/116.3.533

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  40 in total

1.  A nonparametric procedure for comparing the areas under correlated LROC curves.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  IEEE Trans Med Imaging       Date:  2012-06-18       Impact factor: 10.048

2.  Improved detection of focal pneumonia by chest radiography with bone suppression imaging.

Authors:  Feng Li; Roger Engelmann; Lorenzo Pesce; Samuel G Armato; Heber Macmahon
Journal:  Eur Radiol       Date:  2012-07-05       Impact factor: 5.315

Review 3.  ROC analysis in medical imaging: a tutorial review of the literature.

Authors:  Charles E Metz
Journal:  Radiol Phys Technol       Date:  2007-10-27

4.  Evaluating imaging and computer-aided detection and diagnosis devices at the FDA.

Authors:  Brandon D Gallas; Heang-Ping Chan; Carl J D'Orsi; Lori E Dodd; Maryellen L Giger; David Gur; Elizabeth A Krupinski; Charles E Metz; Kyle J Myers; Nancy A Obuchowski; Berkman Sahiner; Alicia Y Toledano; Margarita L Zuley
Journal:  Acad Radiol       Date:  2012-02-03       Impact factor: 3.173

5.  Verification of DICOM GSDF in complex backgrounds.

Authors:  David L Leong; Louise Rainford; Tamara Miner Haygood; Gary J Whitman; Philip M Tchou; William R Geiser; Selin Carkaci; Patrick C Brennan
Journal:  J Digit Imaging       Date:  2012-10       Impact factor: 4.056

6.  Perceptibility and acceptability of CIELAB color differences in computer-simulated teeth.

Authors:  Delwin T Lindsey; Alvin G Wee
Journal:  J Dent       Date:  2007-05-22       Impact factor: 4.379

7.  Holistic crowding: selective interference between configural representations of faces in crowded scenes.

Authors:  Elizabeth G Louie; David W Bressler; David Whitney
Journal:  J Vis       Date:  2007-11-26       Impact factor: 2.240

8.  Three validation metrics for automated probabilistic image segmentation of brain tumours.

Authors:  Kelly H Zou; William M Wells; Ron Kikinis; Simon K Warfield
Journal:  Stat Med       Date:  2004-04-30       Impact factor: 2.373

Review 9.  A brief history of free-response receiver operating characteristic paradigm data analysis.

Authors:  Dev P Chakraborty
Journal:  Acad Radiol       Date:  2013-04-12       Impact factor: 3.173

10.  Operating characteristics predicted by models for diagnostic tasks involving lesion localization.

Authors:  D P Chakraborty; Hong-Jun Yoon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.