Literature DB >> 22337345

Numerical Analysis of Human Sample Effect on RF Penetration and Liver MR Imaging at Ultrahigh Field.

Yong Pang1, Bing Wu, Chunsheng Wang, Daniel B Vigneron, Xiaoliang Zhang.   

Abstract

Magnetic resonance imaging (MRI) can provide clinically-valuable images for hepatic diseases and has become one of the most promising noninvasive methods in evaluating liver lesions. To facilitate the ultrahigh field human liver MRI, in this work, the RF penetration behavior in the conductive and high dielectric human body at the ultrahigh field of 7 Tesla (7T) is investigated and evaluated using the finite-difference time-domain numerical analysis. The study shows that in brain imaging at the ultrahigh field of 7T, the "dielectric resonance" effect dominates among other factors, resulting in improved B(1) penetration; while in liver imaging, due to its irregular geometry of the liver, the "dielectric resonance" effect is not readily to be established, leading to a reduced B(1) penetration or limited image coverage comparing to that in the brain. Therefore, it is necessary to build a large size coil to have deeper penetration to image human liver although the coil design may become more challenging due to the required high frequency. Based on this study, a bisected microstrip coil operating at 300 MHz range is designed and constructed. Three-dimensional in vivo liver images in axial, sagittal and coronal orientations are then acquired from healthy volunteers using this dedicated RF coil on a 7T whole body MR scanner.

Entities:  

Year:  2011        PMID: 22337345      PMCID: PMC3277816          DOI: 10.1002/cmr.b.20209

Source DB:  PubMed          Journal:  Concepts Magn Reson Part B Magn Reson Eng        ISSN: 1552-5031            Impact factor:   1.176


  53 in total

1.  Planar strip array (PSA) for MRI.

Authors:  R F Lee; C R Westgate; R G Weiss; D C Newman; P A Bottomley
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Hepatic MR imaging with a dynamic contrast-enhanced isotropic volumetric interpolated breath-hold examination: feasibility, reproducibility, and technical quality.

Authors:  V S Lee; M T Lavelle; N M Rofsky; G Laub; D M Thomasson; G A Krinsky; J C Weinreb
Journal:  Radiology       Date:  2000-05       Impact factor: 11.105

3.  Microstrip RF surface coil design for extremely high-field MRI and spectroscopy.

Authors:  X Zhang; K Ugurbil; W Chen
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

4.  Investigation of the initial dip in fMRI at 7 Tesla.

Authors:  E Yacoub; A Shmuel; J Pfeuffer; P F Van De Moortele; G Adriany; K Ugurbil; X Hu
Journal:  NMR Biomed       Date:  2001 Nov-Dec       Impact factor: 4.044

5.  Uniform prostate imaging and spectroscopy at 7 T: comparison between a microstrip array and an endorectal coil.

Authors:  Bob van den Bergen; Dennis W J Klomp; Alexander J E Raaijmakers; Catalina Arteaga de Castro; Vincent O Boer; Hugo Kroeze; Peter R Luijten; Jan J W Lagendijk; Cornelis A T van den Berg
Journal:  NMR Biomed       Date:  2010-10-19       Impact factor: 4.044

6.  Tailored utilization of acquired k-space points for GRAPPA reconstruction.

Authors:  Peng Qu; Gary X Shen; Chunsheng Wang; Bing Wu; Jing Yuan
Journal:  J Magn Reson       Date:  2005-05       Impact factor: 2.229

7.  Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging.

Authors:  G C Wiggins; A Potthast; C Triantafyllou; C J Wiggins; L L Wald
Journal:  Magn Reson Med       Date:  2005-07       Impact factor: 4.668

8.  Broadband multicoil imaging using multiple demodulation hardware: a feasibility study.

Authors:  Jin Hyung Lee; Greig C Scott; John M Pauly; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2005-09       Impact factor: 4.668

9.  On Tikhonov regularization for image reconstruction in parallel MRI.

Authors:  Leslie Ying; Dan Xu; Zhi-Pei Liang
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

10.  7T head volume coils: improvements for rostral brain imaging.

Authors:  Nikolai I Avdievich; Hoby P Hetherington; Andrey M Kuznetsov; Jullie W Pan
Journal:  J Magn Reson Imaging       Date:  2009-02       Impact factor: 4.813

View more
  6 in total

1.  Design of catheter radio frequency coils using coaxial transmission line resonators for interventional neurovascular MR imaging.

Authors:  Xiaoliang Zhang; Alastair Martin; Caroline Jordan; Prasheel Lillaney; Aaron Losey; Yong Pang; Jeffrey Hu; Mark Wilson; Daniel Cooke; Steven W Hetts
Journal:  Quant Imaging Med Surg       Date:  2017-04

2.  Hepatic fat assessment using advanced Magnetic Resonance Imaging.

Authors:  Yong Pang; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2012-09

3.  Design and numerical evaluation of a volume coil array for parallel MR imaging at ultrahigh fields.

Authors:  Yong Pang; Ernest W H Wong; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

4.  Parallel imaging performance investigation of an 8-channel common-mode differential-mode (CMDM) planar array for 7T MRI.

Authors:  Xiaoqing Hu; Xiao Chen; Xin Liu; Hairong Zheng; Ye Li; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

5.  Multi-reception strategy with improved SNR for multichannel MR imaging.

Authors:  Bing Wu; Ye Li; Chunsheng Wang; Daniel B Vigneron; Xiaoliang Zhang
Journal:  PLoS One       Date:  2012-08-03       Impact factor: 3.240

6.  Planar quadrature RF transceiver design using common-mode differential-mode (CMDM) transmission line method for 7T MR imaging.

Authors:  Ye Li; Baiying Yu; Yong Pang; Daniel B Vigneron; Xiaoliang Zhang
Journal:  PLoS One       Date:  2013-11-12       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.