Literature DB >> 15968650

Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging.

G C Wiggins1, A Potthast, C Triantafyllou, C J Wiggins, L L Wald.   

Abstract

An eight-channel receive-only brain coil and table-top detunable volume transmit coil were developed and tested at 7 T for human imaging. Optimization of this device required attention to sources of interaction between the array elements, between the transmit and receive coils and minimization of common mode currents on the coaxial cables. Circular receive coils (85 mm dia.) were designed on a flexible former to fit tightly around the head and within a 270-mm diameter TEM transmit volume coil. In the near cortex, the array provided a fivefold increase in SNR compared to a TEM transmit-receive coil, a gain larger than that seen in comparable coils at 3 T. The higher SNR gain is likely due to strong dielectric effects, which cause the volume coil to perform poorly in the cortex compared to centrally. The sensitivity and coverage of the array is demonstrated with high-resolution images of the brain cortex.

Entities:  

Mesh:

Year:  2005        PMID: 15968650     DOI: 10.1002/mrm.20547

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  32 in total

Review 1.  High-resolution MRI: in vivo histology?

Authors:  Holly Bridge; Stuart Clare
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2006-01-29       Impact factor: 6.237

2.  Comparison of three commercially available radio frequency coils for human brain imaging at 3 Tesla.

Authors:  Ralf Mekle; Wietske van der Zwaag; Andreas Joosten; Rolf Gruetter
Journal:  MAGMA       Date:  2008-01-10       Impact factor: 2.310

3.  In vivo imaging of cortical pathology in multiple sclerosis using ultra-high field MRI.

Authors:  Caterina Mainero; T Benner; A Radding; A van der Kouwe; R Jensen; B R Rosen; R P Kinkel
Journal:  Neurology       Date:  2009-07-29       Impact factor: 9.910

4.  Phased array 3D MR spectroscopic imaging of the brain at 7 T.

Authors:  Duan Xu; Charles H Cunningham; Albert P Chen; Yan Li; Douglas A C Kelley; Pratik Mukherjee; John M Pauly; Sarah J Nelson; Daniel B Vigneron
Journal:  Magn Reson Imaging       Date:  2008-05-16       Impact factor: 2.546

5.  Design and Test of Magnetic Wall Decoupling for Dipole Transmit/Receive Array for MR Imaging at the Ultrahigh Field of 7T.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Long Wei; Rong Xue
Journal:  Appl Magn Reson       Date:  2014-11-27       Impact factor: 0.831

6.  Hepatic fat assessment using advanced Magnetic Resonance Imaging.

Authors:  Yong Pang; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2012-09

7.  Design and numerical evaluation of a volume coil array for parallel MR imaging at ultrahigh fields.

Authors:  Yong Pang; Ernest W H Wong; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

8.  Precompensation for mutual coupling between array elements in parallel excitation.

Authors:  Yong Pang; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2011-12

9.  High-resolution phased-array MRI of the human brain at 7 tesla: initial experience in multiple sclerosis patients.

Authors:  Meredith Metcalf; Duan Xu; Darin T Okuda; Lucas Carvajal; Radhika Srinivasan; Douglas A C Kelley; Pratik Mukherjee; Sarah J Nelson; Daniel B Vigneron; Daniel Pelletier
Journal:  J Neuroimaging       Date:  2009-01-29       Impact factor: 2.486

10.  Manipulating transmit and receive sensitivities of radiofrequency surface coils using shielded and unshielded high-permittivity materials.

Authors:  Manushka V Vaidya; Cem M Deniz; Christopher M Collins; Daniel K Sodickson; Riccardo Lattanzi
Journal:  MAGMA       Date:  2017-11-06       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.