Planar strip array (PSA) for MRI.

R F Lee1, C R Westgate, R G Weiss, D C Newman, P A Bottomley.   

Abstract

Parallel, spatial-encoded MRI requires a large number of independent detectors that simultaneously acquire signals. The loop structure and mutual coupling in conventional phased arrays limit the number of coils and therefore the potential reduction in minimum scan time achievable by parallel MRI tchniques. A new near-field MRI detector array, the planar strip array (PSA), is presented that eliminates the coupling problems and can be extended to a very large number of detectors and high MRI frequencies. Its basic structure is an array of parallel microstrips with a high permittivity substrate and overlay. The electromagnetic (EM) wavelength can be adjusted with the permittivity, and the strip lengths tuned to a preselected fraction of the wavelength of the MRI frequency. EM wave analysis and measurements on a prototype four-element PSA reveal that the coupling between the strips vanishes when the strip length is either an integer times a quarter wavelength for a standing-wave PSA, or a half wavelength for a travelling-wave PSA, independent of the spacing between the strips. The analysis, as well as phantom and human MRI experiments performed by conventional and parallel-encoded MRI with the PSA at 1.5 T, show that the decoupled strips produce a relatively high-quality factor and signal-to-noise ratio, provided that the strips are properly terminated, tuned, and matched or coupled to the preamplifiers. Magn Reson Med 45:673-683, 2001. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11283996      PMCID: PMC1941687          DOI: 10.1002/mrm.1090

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  An analytical SMASH procedure (ASP) for sensitivity-encoded MRI.

Authors:  R F Lee; C R Westgate; R G Weiss; P A Bottomley
Journal:  Magn Reson Med       Date:  2000-05       Impact factor: 4.668

2.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

3.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

4.  A decoupled coil detector array for fast image acquisition in magnetic resonance imaging.

Authors:  D Kwiat; S Einav; G Navon
Journal:  Med Phys       Date:  1991 Mar-Apr       Impact factor: 4.071

5.  An analytical model for the design of RF resonators for MR body imaging.

Authors:  T K Foo; C E Hayes; Y W Kang
Journal:  Magn Reson Med       Date:  1991-10       Impact factor: 4.668

6.  AUTO-SMASH: a self-calibrating technique for SMASH imaging. SiMultaneous Acquisition of Spatial Harmonics.

Authors:  P M Jakob; M A Griswold; R R Edelman; D K Sodickson
Journal:  MAGMA       Date:  1998-11       Impact factor: 2.310

7.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

8.  Intravascular magnetic resonance imaging using a loopless catheter antenna.

Authors:  O Ocali; E Atalar
Journal:  Magn Reson Med       Date:  1997-01       Impact factor: 4.668

9.  A broadband phased-array system for direct phosphorus and sodium metabolic MRI on a clinical scanner.

Authors:  R F Lee; R Giaquinto; C Constantinides; S Souza; R G Weiss; P A Bottomley
Journal:  Magn Reson Med       Date:  2000-02       Impact factor: 4.668

10.  High frequency volume coils for clinical NMR imaging and spectroscopy.

Authors:  J T Vaughan; H P Hetherington; J O Otu; J W Pan; G M Pohost
Journal:  Magn Reson Med       Date:  1994-08       Impact factor: 4.668

View more
  19 in total

1.  Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRI.

Authors:  Daniel K Sodickson; Charles A McKenzie; Michael A Ohliger; Ernest N Yeh; Mark D Price
Journal:  MAGMA       Date:  2002-01       Impact factor: 2.310

2.  Investigation of multichannel phased array performance for fetal MR imaging on 1.5T clinical MR system.

Authors:  Ye Li; Yong Pang; Daniel Vigneron; Orit Glenn; Duan Xu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2011-01-01

3.  Lumped-element planar strip array (LPSA) for parallel MRI.

Authors:  Ray F Lee; Christopher J Hardy; Daniel K Sodickson; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

4.  Linear microstrip surface coil for MR imaging of the rat spinal cord at 4.7 T.

Authors:  M Burian; M Hájek
Journal:  MAGMA       Date:  2004-12-01       Impact factor: 2.310

5.  Optimizing the intrinsic signal-to-noise ratio of MRI strip detectors.

Authors:  Ananda Kumar; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

6.  ICE decoupling technique for RF coil array designs.

Authors:  Ye Li; Zhentian Xie; Yong Pang; Daniel Vigneron; Xiaoliang Zhang
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

7.  Stripline resonator and preamplifier for preclinical magnetic resonance imaging at 4.7 T.

Authors:  Ioannis Lavdas; Hugh C Seton; Charles R Harrington; Claude M Wischik
Journal:  MAGMA       Date:  2011-08-04       Impact factor: 2.310

8.  Flexible transceiver array for ultrahigh field human MR imaging.

Authors:  Bing Wu; Xiaoliang Zhang; Chunsheng Wang; Ye Li; Yong Pang; Jonathan Lu; Duan Xu; Sharmila Majumdar; Sarah J Nelson; Daniel B Vigneron
Journal:  Magn Reson Med       Date:  2012-01-13       Impact factor: 4.668

9.  A dual-tuned quadrature volume coil with mixed λ/2 and λ/4 microstrip resonators for multinuclear MRSI at 7 T.

Authors:  Yong Pang; Zhentian Xie; Duan Xu; Douglas A Kelley; Sarah J Nelson; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Magn Reson Imaging       Date:  2011-11-03       Impact factor: 2.546

10.  4 T Actively detuneable double-tuned 1H/31P head volume coil and four-channel 31P phased array for human brain spectroscopy.

Authors:  N I Avdievich; H P Hetherington
Journal:  J Magn Reson       Date:  2007-03-03       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.