Literature DB >> 16086362

Broadband multicoil imaging using multiple demodulation hardware: a feasibility study.

Jin Hyung Lee1, Greig C Scott, John M Pauly, Dwight G Nishimura.   

Abstract

Multiple receiver-coil data collection is an effective approach to reduce scan time. There are many parallel imaging techniques that reduce scan time using multiple receiver coils. One of these methods, partially parallel imaging with localized sensitivities (PILS), utilizes the localized sensitivity of each coil. The advantages of PILS over other parallel imaging methods include the simplicity of the algorithm, good signal-to-noise ratio (SNR) properties, and the fact that there is no additional complexity involved in applying the algorithm to arbitrary k-space trajectories. This PILS method can be further improved to provide truly parallel broadband imaging with the use of multiple-demodulation hardware. By customizing the demodulation based on each coil's location, the k-space sampling rate can be chosen based on each coil's localized sensitivity region along the readout direction. A simulated demodulation of data from 2D Fourier transform (FT) and spiral trajectories is shown to demonstrate the method's feasibility. Copyright (c) 2005 Wiley-Liss, Inc.

Mesh:

Year:  2005        PMID: 16086362     DOI: 10.1002/mrm.20595

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  Simultaneous bilateral-knee MR imaging.

Authors:  Feliks Kogan; Evan Levine; Akshay S Chaudhari; Uchechukwuka D Monu; Kevin Epperson; Edwin H G Oei; Garry E Gold; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2017-12-17       Impact factor: 4.668

2.  Variable-density parallel imaging with partially localized coil sensitivities.

Authors:  Tolga Cukur; Juan M Santos; John M Pauly; Dwight G Nishimura
Journal:  IEEE Trans Med Imaging       Date:  2010-03-15       Impact factor: 10.048

3.  Numerical Analysis of Human Sample Effect on RF Penetration and Liver MR Imaging at Ultrahigh Field.

Authors:  Yong Pang; Bing Wu; Chunsheng Wang; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2011-10       Impact factor: 1.176

4.  Aliasing artifact reduction in spiral real-time MRI.

Authors:  Ye Tian; Yongwan Lim; Ziwei Zhao; Dani Byrd; Shrikanth Narayanan; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2021-03-16       Impact factor: 3.737

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.