Literature DB >> 19161203

7T head volume coils: improvements for rostral brain imaging.

Nikolai I Avdievich1, Hoby P Hetherington, Andrey M Kuznetsov, Jullie W Pan.   

Abstract

PURPOSE: To improve the performance of 7T head coils over the rostral head regions. Due to radiofrequency (RF) field/tissue interactions, the RF magnetic field profile produced by 7T volume head coils is very inhomogeneous, with enhanced sensitivity near the center of the human brain and substantially reduced in the periphery.
MATERIALS AND METHODS: Two head-sized quadrature volume coils of similar diameters but substantially different lengths (17 and 10 cm) were constructed and tested using a 7T Varian Inova system.
RESULTS: Experimental data demonstrated that by using a shorter volume head-sized coil or simply by partially moving a head out of the coil, coil efficiency near the top of a head can be improved by 20%. The homogeneity also improved, largely resulting from an increase in peripheral B(1) values. This resulted in 10%-20% variation in axial slices located near the top of a head.
CONCLUSION: We have demonstrated a less deeply positioned head or substantially shorter volume coil can significantly improve coil performance and homogeneity for the rostral head at ultrahigh magnetic fields (7T and above). For studies that target superior brain regions, this coil arrangement can be highly effective.

Entities:  

Mesh:

Year:  2009        PMID: 19161203      PMCID: PMC2756104          DOI: 10.1002/jmri.21660

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  15 in total

1.  Effect of RF coil excitation on field inhomogeneity at ultra high fields: a field optimized TEM resonator.

Authors:  T S Ibrahim; R Lee; B A Baertlein; A M Abduljalil; H Zhu; P M Robitaille
Journal:  Magn Reson Imaging       Date:  2001-12       Impact factor: 2.546

2.  7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images.

Authors:  J T Vaughan; M Garwood; C M Collins; W Liu; L DelaBarre; G Adriany; P Andersen; H Merkle; R Goebel; M B Smith; K Ugurbil
Journal:  Magn Reson Med       Date:  2001-07       Impact factor: 4.668

3.  Analysis of wave behavior in lossy dielectric samples at high field.

Authors:  Qing X Yang; Jinghua Wang; Xiaoliang Zhang; Christopher M Collins; Michael B Smith; Haiying Liu; Xiao-Hong Zhu; J Thomas Vaughan; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

4.  Detunable transverse electromagnetic (TEM) volume coil for high-field NMR.

Authors:  J T Vaughan; G Adriany; M Garwood; E Yacoub; T Duong; L DelaBarre; P Andersen; K Ugurbil
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

5.  4 T actively detunable transmit/receive transverse electromagnetic coil and 4-channel receive-only phased array for (1)H human brain studies.

Authors:  Nikolai I Avdievich; Hoby P Hetherington
Journal:  Magn Reson Med       Date:  2004-12       Impact factor: 4.668

6.  Central brightening due to constructive interference with, without, and despite dielectric resonance.

Authors:  Christopher M Collins; Wanzhan Liu; Weston Schreiber; Qing X Yang; Michael B Smith
Journal:  J Magn Reson Imaging       Date:  2005-02       Impact factor: 4.813

7.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Authors:  Gregor Adriany; Pierre-Francois Van de Moortele; Florian Wiesinger; Steen Moeller; John P Strupp; Peter Andersen; Carl Snyder; Xiaoliang Zhang; Wei Chen; Klaas P Pruessmann; Peter Boesiger; Tommy Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

8.  High frequency volume coils for clinical NMR imaging and spectroscopy.

Authors:  J T Vaughan; H P Hetherington; J O Otu; J W Pan; G M Pohost
Journal:  Magn Reson Med       Date:  1994-08       Impact factor: 4.668

9.  Quantitative spectroscopic imaging of the human brain.

Authors:  J W Pan; D B Twieg; H P Hetherington
Journal:  Magn Reson Med       Date:  1998-09       Impact factor: 4.668

10.  Frontal lobe GABA levels in cocaine dependence: a two-dimensional, J-resolved magnetic resonance spectroscopy study.

Authors:  Yong Ke; Chris C Streeter; Leanne E Nassar; Ofra Sarid-Segal; John Hennen; Deborah A Yurgelun-Todd; Lily A Awad; Melanie J Rendall; Staci A Gruber; Ariel Nason; Melissa J Mudrick; Steven R Blank; Angela A Meyer; Clifford Knapp; Domenic A Ciraulo; Perry F Renshaw
Journal:  Psychiatry Res       Date:  2004-04-30       Impact factor: 3.222

View more
  8 in total

1.  J-refocused coherence transfer spectroscopic imaging at 7 T in human brain.

Authors:  J W Pan; N Avdievich; H P Hetherington
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

2.  Hepatic fat assessment using advanced Magnetic Resonance Imaging.

Authors:  Yong Pang; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2012-09

3.  Transparent thin shield for radio frequency transmit coils.

Authors:  Debra S Rivera; Jessica Schulz; Thomas Siegert; Verena Zuber; Robert Turner
Journal:  MAGMA       Date:  2014-05-27       Impact factor: 2.310

4.  Effect of the extracranial deep brain stimulation lead on radiofrequency heating at 9.4 Tesla (400.2 MHz).

Authors:  Devashish Shrivastava; Aviva Abosch; Timothy Hanson; Jinfeng Tian; Akshay Gupte; Paul A Iaizzo; J Thomas Vaughan
Journal:  J Magn Reson Imaging       Date:  2010-09       Impact factor: 4.813

5.  Numerical Analysis of Human Sample Effect on RF Penetration and Liver MR Imaging at Ultrahigh Field.

Authors:  Yong Pang; Bing Wu; Chunsheng Wang; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2011-10       Impact factor: 1.176

6.  Ultra-high-field RF coil development for evaluating upper extremity imaging applications.

Authors:  Shailesh B Raval; Tiejun Zhao; Narayanan Krishnamurthy; Tales Santini; Cynthia Britton; Vijay S Gorantla; Tamer S Ibrahim
Journal:  NMR Biomed       Date:  2016-11-03       Impact factor: 4.044

7.  MRSI of the medial temporal lobe at 7 T in explosive blast mild traumatic brain injury.

Authors:  Hoby P Hetherington; Hamada Hamid; Joseph Kulas; Geoffrey Ling; Faris Bandak; Nihal C de Lanerolle; Jullie W Pan
Journal:  Magn Reson Med       Date:  2013-08-05       Impact factor: 4.668

8.  Transceiver-Phased Arrays for Human Brain Studies at 7 T.

Authors:  Nikolai I Avdievich
Journal:  Appl Magn Reson       Date:  2011-12       Impact factor: 0.831

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.