Hepatic MR imaging with a dynamic contrast-enhanced isotropic volumetric interpolated breath-hold examination: feasibility, reproducibility, and technical quality.

V S Lee1, M T Lavelle, N M Rofsky, G Laub, D M Thomasson, G A Krinsky, J C Weinreb.   

Abstract

PURPOSE: To evaluate the feasibility, reproducibility, and technical quality of a dynamic contrast material-enhanced isotropic three-dimensional (3D) volumetric interpolated breath-hold hepatic magnetic resonance (MR) imaging examination.
MATERIALS AND METHODS: Fifty patients underwent 3D spoiled gradient-echo imaging (4.2/1.8 [repetition time msec/echo time msec]; flip angle, 12 degrees; interpolation in three directions; intermittent fat saturation; pixel size </= 2.5 mm in all dimensions) before and dynamically after administration of gadopentetate dimeglumine, with the first enhanced acquisition timed for hepatic arterial dominance by using a test bolus of contrast material. Qualitative and quantitative measures of image quality were determined. Patterns of arterial and venous anatomy were assessed. Ten patients (20%) underwent repeat imaging within 6 months, and reproducibility was evaluated.
RESULTS: Hepatic contrast-to-noise ratios for nonenhanced and arterial, portal venous, and equilibrium phase studies averaged 13.0 +/- 12.6 (SD), 17.4 +/- 11.8, 30.4 +/- 16.2, and 28.6 +/- 21.1, respectively. During arterial phase, the liver enhanced a mean of 29% of the maximal enhancement as measured during portal venous phase. Hepatic vascular anatomic variants were comparable in distribution to those cited in published articles. Repeat studies were not significantly different in image quality when compared with original studies.
CONCLUSION: High-quality arterial phase 3D volumetric interpolated breath-hold images can be obtained reliably and reproducibly when timed by using a test dose of contrast material.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10796909     DOI: 10.1148/radiology.215.2.r00ma16365

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  22 in total

Review 1.  [Modern visualization of the liver with MRT. Current trends and future perspectives].

Authors:  C J Zech; S O Schoenberg; K A Herrmann; O Dietrich; M I Menzel; T Lanz; A Wallnöfer; T Helmberger; M F Reiser
Journal:  Radiologe       Date:  2004-12       Impact factor: 0.635

2.  Prospective intraindividual comparison between respiratory-triggered balanced steady-state free precession and breath-hold gradient-echo and time-of-flight magnetic resonance imaging for assessment of portal and hepatic veins.

Authors:  Jürgen K Willmann; Kerstin Göpfert; Amelie M Lutz; Daniel Nanz; Lucas McCormack; Henrik Petrowsky; Burkhardt Seifert; Patrice Hervo; Borut Marincek; Dominik Weishaupt
Journal:  Eur Radiol       Date:  2006-05-16       Impact factor: 5.315

Review 3.  MRA of abdominal vessels: technical advances.

Authors:  Henrik J Michaely; Olaf Dietrich; Kambiz Nael; Sabine Weckbach; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-05-24       Impact factor: 5.315

4.  Assessment of the abdominal aorta and its visceral branches by contrast-enhanced dynamic volumetric hepatic parallel magnetic resonance imaging: feasibility, reliability and accuracy.

Authors:  Robert Werder; Daniel Nanz; Amelie M Lutz; Dominik Weishaupt; Lucas McCormack; Burkhardt Seifert; Borut Marincek; Jürgen K Willmann
Journal:  Eur Radiol       Date:  2006-09-01       Impact factor: 5.315

5.  CAIPIRINHA-VIBE and GRAPPA-VIBE for liver MRI at 1.5 T: a comparative in vivo patient study.

Authors:  Ajaykumar C Morani; Rafael A Vicens; Wei Wei; Shiva Gupta; Raghu Vikram; Aparna Balachandran; Brandy J Reed; Jingfei Ma; Aliya Qayyum; Janio Szklaruk
Journal:  J Comput Assist Tomogr       Date:  2015 Mar-Apr       Impact factor: 1.826

6.  Hepatic fat assessment using advanced Magnetic Resonance Imaging.

Authors:  Yong Pang; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2012-09

7.  Three-dimensional volumetric MRI with isotropic resolution: improved speed of acquisition, spatial resolution and assessment of lesion conspicuity in patients with recurrent soft tissue sarcoma.

Authors:  Shivani Ahlawat; Carol Morris; Laura M Fayad
Journal:  Skeletal Radiol       Date:  2016-02-20       Impact factor: 2.199

Review 8.  Magnetic Resonanance Imaging of the Liver (Including Biliary Contrast Agents)-Part 2: Protocols for Liver Magnetic Resonanance Imaging and Characterization of Common Focal Liver Lesions.

Authors:  Andrea Agostini; Moritz F Kircher; Richard K G Do; Alessandra Borgheresi; Serena Monti; Andrea Giovagnoni; Lorenzo Mannelli
Journal:  Semin Roentgenol       Date:  2016-05-30       Impact factor: 0.800

9.  Standardized quantitative measurements of wrist cartilage in healthy humans using 3T magnetic resonance imaging.

Authors:  Jean-Vincent Zink; Philippe Souteyrand; Sandrine Guis; Christophe Chagnaud; Yann Le Fur; Daniela Militianu; Jean-Pierre Mattei; Michael Rozenbaum; Itzhak Rosner; Maxime Guye; Monique Bernard; David Bendahan
Journal:  World J Orthop       Date:  2015-09-18

10.  Automatic ROI construction for analyzing time-signal intensity curve in dynamic contrast-enhanced MR imaging of the breast.

Authors:  Koya Fujimoto; Yasuyuki Ueda; Shohei Kudomi; Teppei Yonezawa; Yuki Fujimoto; Katsuhiko Ueda
Journal:  Radiol Phys Technol       Date:  2015-07-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.