Effects of motion, attenuation, and scatter corrections on gated cardiac SPECT reconstruction.

Xiaofeng Niu1, Yongyi Yang, Mingwu Jin, Miles N Wernick, Michael A King.   

Abstract

PURPOSE: In gated cardiac single photon emission computed tomography (SPECT), image reconstruction is often hampered by various degrading factors including depth-dependent spatial blurring, attenuation, scatter, motion blurring, and low data counts. Consequently, there has been significant development in image reconstruction methods for improving the quality of reconstructed images. The goal of this work is to investigate how these degrading factors will impact the reconstructed myocardium when different reconstruction methods are used.
METHODS: The authors conduct a comparative study of the effects of these degrading factors on the accuracy of myocardium by several reconstruction algorithms, including (1) a clinical spatiotemporal processing method, (2) maximum likelihood (ML) estimation, (3) 3D maximum a posteriori (MAP) estimation, (4) 3D MAP with posttemporal filtering, and (5) motion-compensated spatiotemporal (4D) reconstruction. To quantify the reconstruction results, the authors use the following measures on different aspects of the myocardium: (1) overall error level in the myocardium, (2) regional accuracy of the left ventricle (LV) wall, (3) uniformity of the LV, (4) accuracy of regional time activity curves by normalized cross-correlation coefficient, and (5) perfusion defect detectability. The authors also assess the effectiveness of degrading corrections in reconstruction by considering an upper bound for each reconstruction method, which represents what would be achieved by each method if the acquired data were free from attenuation and scatter degradations. In the experiments the authors use Monte Carlo simulated cardiac gated SPECT imaging based on the 4D NURBS-based cardiac-torso (NCAT) phantom with different patient geometry and lesion settings, in which the simulated ground truth is known for the purpose of quantitative evaluation.
RESULTS: The results demonstrate that use of temporal processing in reconstruction (Methods 1, 4, and 5 above) can greatly improve the reconstructed myocardium in terms of both error level and perfusion defect detection. In low-count gated studies, it can have even greater impact than other degrading factors. Both attenuation and scatter corrections can lead to reduced error levels in the myocardium in all methods; in particular, with 4D the bias can be reduced by as much as four-fold compared to no correction. There is a slight increase in noise level observed with scatter correction. A significant improvement in heart wall appearance is demonstrated in reconstruction results from three sets of clinical acquisitions as correction for degradations is combined with refinement of temporal filtering.
CONCLUSIONS: Correction for degrading factors such as resolution, attenuation, scatter, and motion blur can all lead to improved image quality in cardiac gated SPECT reconstruction. However, their effectiveness could also vary with the reconstruction algorithms used. Both attenuation and scatter corrections can effectively reduce the bias level of the reconstructed LV wall, though scatter correction is also observed to increase the variance level. Use of temporal processing in reconstruction can have greater impact on the accuracy of the myocardium than correction of other degrading factors. Overall, use of degrading corrections in 4D reconstruction is shown to be most effective for improving both reconstruction accuracy of the myocardium and detectability of perfusion defects in gated images.

Entities:  

Mesh:

Year:  2011        PMID: 22149839      PMCID: PMC3247926          DOI: 10.1118/1.3660328

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  15 in total

1.  Effects of scatter substraction on detection and quantitation in hepatic SPECT.

Authors:  D J de Vries; M A King; E J Soares; B M Tsui; C E Metz
Journal:  J Nucl Med       Date:  1999-06       Impact factor: 10.057

2.  Receiver operating characteristic evaluation of iterative reconstruction with attenuation correction in 99mTc-sestamibi myocardial SPECT images.

Authors:  K J LaCroix; B M Tsui; E C Frey; R J Jaszczak
Journal:  J Nucl Med       Date:  2000-03       Impact factor: 10.057

3.  Spatiotemporal processing of gated cardiac SPECT images using deformable mesh modeling.

Authors:  Jovan G Brankov; Yongyi Yang; Miles N Wernick
Journal:  Med Phys       Date:  2005-09       Impact factor: 4.071

4.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

5.  Extracardiac activity complicates quantitative cardiac SPECT imaging using a simultaneous transmission-emission approach.

Authors:  E N Heller; P DeMan; Y H Liu; D P Dione; I G Zubal; F J Wackers; A J Sinusas
Journal:  J Nucl Med       Date:  1997-12       Impact factor: 10.057

6.  Block-iterative techniques for fast 4D reconstruction using a priori motion models in gated cardiac SPECT.

Authors:  D S Lalush; B M Tsui
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

7.  A Monte Carlo program for the simulation of scintillation camera characteristics.

Authors:  M Ljungberg; S E Strand
Journal:  Comput Methods Programs Biomed       Date:  1989-08       Impact factor: 5.428

8.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

9.  EM reconstruction algorithms for emission and transmission tomography.

Authors:  K Lange; R Carson
Journal:  J Comput Assist Tomogr       Date:  1984-04       Impact factor: 1.826

10.  Comparing filtered backprojection and ordered-subsets expectation maximization for small-lesion detection and localization in 67Ga SPECT.

Authors:  R G Wells; M A King; P H Simkin; P F Judy; A B Brill; H C Gifford; R Licho; P H Pretorius; P B Schneider; D W Seldin
Journal:  J Nucl Med       Date:  2000-08       Impact factor: 10.057

View more
  10 in total

1.  Limited-angle effect compensation for respiratory binned cardiac SPECT.

Authors:  Wenyuan Qi; Yongyi Yang; Miles N Wernick; P Hendrik Pretorius; Michael A King
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

2.  A quantitative study of motion estimation methods on 4D cardiac gated SPECT reconstruction.

Authors:  Wenyuan Qi; Yongyi Yang; Xiaofeng Niu; Michael A King
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

3.  Gated SPECT myocardial perfusion imaging quality assurance in current and future practice.

Authors:  Kenneth J Nichols; Andrew Van Tosh
Journal:  J Nucl Cardiol       Date:  2016-12-21       Impact factor: 5.952

4.  4D reconstruction for low-dose cardiac gated SPECT.

Authors:  Mingwu Jin; Xiaofeng Niu; Wenyuan Qi; Yongyi Yang; Joyoni Dey; Michael A King; Seth Dahlberg; Miles N Wernick
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

5.  4D non-local means post-filtering for cardiac gated SPECT.

Authors:  Chao Song; Yongyi Yang; P Hendrik Pretorius; Michael A King
Journal:  Phys Med Biol       Date:  2018-01-31       Impact factor: 3.609

6.  Comparison of sparse domain approaches for 4D SPECT dynamic image reconstruction.

Authors:  Debasis Mitra; Mahmoud Abdalah; Rostyslav Boutchko; Haoran Chang; Uttam Shrestha; Elias Botvinick; Youngho Seo; Grant T Gullberg
Journal:  Med Phys       Date:  2018-08-31       Impact factor: 4.071

7.  4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT.

Authors:  Wenyuan Qi; Yongyi Yang; Chao Song; Miles N Wernick; P Hendrik Pretorius; Michael A King
Journal:  IEEE Trans Med Imaging       Date:  2017-04-04       Impact factor: 10.048

8.  Variation of Contrast Values for Myocardial Perfusion Imaging in Single-photon Emission Computed Tomography/Computed Tomography Hybrid Systems with Different Correction Methods.

Authors:  Hazem M Tantawy; Yasser G Abdelhafez; Nadia L Helal; Ibrahim E Saad
Journal:  J Clin Imaging Sci       Date:  2020-09-25

9.  Task-based evaluation of a 4D MAP-RBI-EM image reconstruction method for gated myocardial perfusion SPECT using a human observer study.

Authors:  Taek-Soo Lee; Takahiro Higuchi; Riikka Lautamäki; Frank M Bengel; Benjamin M W Tsui
Journal:  Phys Med Biol       Date:  2015-08-24       Impact factor: 3.609

Review 10.  Recent trends in nuclear cardiology practice.

Authors:  Kyoung Sook Won; Bong-Il Song
Journal:  Chonnam Med J       Date:  2013-08-22
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.