Literature DB >> 29283356

4D non-local means post-filtering for cardiac gated SPECT.

Chao Song1, Yongyi Yang, P Hendrik Pretorius, Michael A King.   

Abstract

Cardiac gated images often suffer from increased noise in single photon emission computed tomography (SPECT) due to reduced data counts compared to non-gated studies. We investigate a spatiotemporal post-processing approach based on a non-local means (NLM) filter for suppressing the noise in gated SPECT images. In this filter, the output at a voxel location is computed from a weighted average of voxels in its four-dimensional (4D) neighborhood, wherein the filter coefficients are adjusted according to the similarity level in the local image pattern of individual voxels with respect to the output voxel. This adaptive property allows the filter to achieve noise reduction while avoiding excessive blur of the heart wall. In the experiments, we first evaluated the accuracy of the proposed NLM filtering approach using simulated SPECT imaging data. We then demonstrated the approach on eight sets of clinical acquisitions. In addition, we also explored the robustness of the NLM filter with imaging dose reduced by 50% in these clinical acquisitions. The quantitative results show that 4D NLM filtering could effectively reduce the noise level in gated images, leading to more accurate reconstruction of the myocardium. Compared to spatial filtering alone, using temporal filtering in NLM could reduce the mean-squared-error of the myocardium by 55.63% and improve the left ventricle resolution by 19.92%. It could also improve the visibility of perfusion defects in gated images. Similar results are also observed on the clinical acquisitions both at standard dose and at 50% reduced dose. The 4D NLM results are also found to be comparable to that of a motion-compensated 4D reconstruction approach which is computationally more demanding.

Entities:  

Mesh:

Year:  2018        PMID: 29283356      PMCID: PMC5987531          DOI: 10.1088/1361-6560/aaa44d

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  Effects of motion, attenuation, and scatter corrections on gated cardiac SPECT reconstruction.

Authors:  Xiaofeng Niu; Yongyi Yang; Mingwu Jin; Miles N Wernick; Michael A King
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Spatiotemporal processing of gated cardiac SPECT images using deformable mesh modeling.

Authors:  Jovan G Brankov; Yongyi Yang; Miles N Wernick
Journal:  Med Phys       Date:  2005-09       Impact factor: 4.071

3.  Fully 4D motion-compensated reconstruction of cardiac SPECT images.

Authors:  Erwan Gravier; Yongyi Yang; Michael A King; Mingwu Jin
Journal:  Phys Med Biol       Date:  2006-08-30       Impact factor: 3.609

4.  Evaluation of a low-dose/slow-rotating SPECT-CT system.

Authors:  M Hamann; M Aldridge; J Dickson; R Endozo; K Lozhkin; B F Hutton
Journal:  Phys Med Biol       Date:  2008-04-18       Impact factor: 3.609

5.  High diagnostic accuracy of low-dose gated-SPECT with solid-state ultrafast detectors: preliminary clinical results.

Authors:  Alessia Gimelli; Matteo Bottai; Dario Genovesi; Assuero Giorgetti; Fabio Di Martino; Paolo Marzullo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-09-02       Impact factor: 9.236

6.  Block-iterative techniques for fast 4D reconstruction using a priori motion models in gated cardiac SPECT.

Authors:  D S Lalush; B M Tsui
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

7.  4D reconstruction for low-dose cardiac gated SPECT.

Authors:  Mingwu Jin; Xiaofeng Niu; Wenyuan Qi; Yongyi Yang; Joyoni Dey; Michael A King; Seth Dahlberg; Miles N Wernick
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

8.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

9.  Filtering in SPECT Image Reconstruction.

Authors:  Maria Lyra; Agapi Ploussi
Journal:  Int J Biomed Imaging       Date:  2011-06-23

10.  Non-local means denoising of dynamic PET images.

Authors:  Joyita Dutta; Richard M Leahy; Quanzheng Li
Journal:  PLoS One       Date:  2013-12-05       Impact factor: 3.240

View more
  2 in total

1.  Deep Learning-Based Diffusion-Weighted Magnetic Resonance Imaging in the Diagnosis of Ischemic Penumbra in Early Cerebral Infarction.

Authors:  Hui Sheng; Xueling Wang; Meiping Jiang; Zhongsheng Zhang
Journal:  Contrast Media Mol Imaging       Date:  2022-02-28       Impact factor: 3.161

2.  Deep learning with noise-to-noise training for denoising in SPECT myocardial perfusion imaging.

Authors:  Junchi Liu; Yongyi Yang; Miles N Wernick; P Hendrik Pretorius; Michael A King
Journal:  Med Phys       Date:  2020-11-23       Impact factor: 4.071

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.