Literature DB >> 28391190

4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT.

Wenyuan Qi, Yongyi Yang, Chao Song, Miles N Wernick, P Hendrik Pretorius, Michael A King.   

Abstract

Cardiac single photon emission computed tomography (SPECT) images are known to suffer from both cardiac and respiratory motion blur. In this paper, we investigate a 4-D reconstruction approach to suppress the effect of respiratory motion in gated cardiac SPECT imaging. In this approach, the sequence of cardiac gated images is reconstructed with respect to a reference respiratory amplitude bin in the respiratory cycle. To combat the challenge of inherent high-imaging noise, we utilize the data counts acquired during the entire respiratory cycle by making use of a motion-compensated scheme, in which both cardiac motion and respiratory motion are taken into account. In the experiments, we first use Monte Carlo simulated imaging data, wherein the ground truth is known for quantitative comparison. We then demonstrate the proposed approach on eight sets of clinical acquisitions, in which the subjects exhibit different degrees of respiratory motion blur. The quantitative evaluation results show that the 4-D reconstruction with respiratory correction could effectively reduce the effect of motion blur and lead to a more accurate reconstruction of the myocardium. The mean-squared error of the myocardium is reduced by 22%, and the left ventricle (LV) resolution is improved by 21%. Such improvement is also demonstrated with the clinical acquisitions, where the motion blur is markedly improved in the reconstructed LV wall and blood pool. The proposed approach is also noted to be effective on correcting the spill-over effect in the myocardium from nearby bowel or liver activities.

Entities:  

Mesh:

Year:  2017        PMID: 28391190      PMCID: PMC5595423          DOI: 10.1109/TMI.2017.2690819

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  29 in total

1.  Updated imaging guidelines for nuclear cardiology procedures, part 1.

Authors: 
Journal:  J Nucl Cardiol       Date:  2001 Jan-Feb       Impact factor: 5.952

2.  "Motion-frozen" display and quantification of myocardial perfusion.

Authors:  Piotr J Slomka; Hidetaka Nishina; Daniel S Berman; Xingping Kang; Cigdem Akincioglu; John D Friedman; Sean W Hayes; Usaf E Aladl; Guido Germano
Journal:  J Nucl Med       Date:  2004-07       Impact factor: 10.057

3.  Effects of motion, attenuation, and scatter corrections on gated cardiac SPECT reconstruction.

Authors:  Xiaofeng Niu; Yongyi Yang; Mingwu Jin; Miles N Wernick; Michael A King
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

4.  Block-iterative techniques for fast 4D reconstruction using a priori motion models in gated cardiac SPECT.

Authors:  D S Lalush; B M Tsui
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

5.  End-expiration respiratory gating for a high-resolution stationary cardiac SPECT system.

Authors:  Chung Chan; Mark Harris; Max Le; James Biondi; Yariv Grobshtein; Yi-Hwa Liu; Albert J Sinusas; Chi Liu
Journal:  Phys Med Biol       Date:  2014-09-26       Impact factor: 3.609

6.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

7.  Use of a nonstationary temporal Wiener filter in nuclear medicine.

Authors:  M A King; T R Miller
Journal:  Eur J Nucl Med       Date:  1985

8.  Motion correction in dual gated cardiac PET using mass-preserving image registration.

Authors:  Fabian Gigengack; Lars Ruthotto; Martin Burger; Carsten H Wolters; Xiaoyi Jiang; Klaus P Schäfers
Journal:  IEEE Trans Med Imaging       Date:  2011-11-09       Impact factor: 10.048

9.  Estimation and correction of cardiac respiratory motion in SPECT in the presence of limited-angle effects due to irregular respiration.

Authors:  Joyoni Dey; William P Segars; P Hendrik Pretorius; Ronn P Walvick; Philippe P Bruyant; Seth Dahlberg; Michael A King
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

10.  Dual "motion-frozen heart" combining respiration and contraction compensation in clinical myocardial perfusion SPECT imaging.

Authors:  Gil Kovalski; Zohar Keidar; Alex Frenkel; Jonathan Sachs; Shai Attia; Haim Azhari
Journal:  J Nucl Cardiol       Date:  2009-01-22       Impact factor: 5.952

View more
  3 in total

1.  Personalized Models for Injected Activity Levels in SPECT Myocardial Perfusion Imaging.

Authors:  Albert Juan Ramon; Yongyi Yang; P Hendrik Pretorius; Karen L Johnson; Michael A King; Miles N Wernick
Journal:  IEEE Trans Med Imaging       Date:  2018-12-06       Impact factor: 10.048

2.  Improving perfusion defect detection with respiratory motion correction in cardiac SPECT at standard and reduced doses.

Authors:  Chao Song; Yongyi Yang; Albert Juan Ramon; Miles N Wernick; P Hendrik Pretorius; Karen L Johnson; Piotr J Slomka; Michael A King
Journal:  J Nucl Cardiol       Date:  2018-07-30       Impact factor: 5.952

3.  Deep learning with noise-to-noise training for denoising in SPECT myocardial perfusion imaging.

Authors:  Junchi Liu; Yongyi Yang; Miles N Wernick; P Hendrik Pretorius; Michael A King
Journal:  Med Phys       Date:  2020-11-23       Impact factor: 4.071

  3 in total