Simultaneous variable flip angle-actual flip angle imaging method for improved accuracy and precision of three-dimensional T1 and B1 measurements.

Samuel A Hurley1, Vasily L Yarnykh, Kevin M Johnson, Aaron S Field, Andrew L Alexander, Alexey A Samsonov.   

Abstract

A new time-efficient and accurate technique for simultaneous mapping of T(1) and B(1) is proposed based on a combination of the actual flip angle (FA) imaging and variable FA methods. Variable FA-actual FA imaging utilizes a single actual FA imaging and one or more spoiled gradient-echo acquisitions with a simultaneous nonlinear fitting procedure to yield accurate T(1)/B(1) maps. The advantage of variable FA-actual FA imaging is high accuracy at either short T(1) times or long repetition times in the actual FA imaging sequence. Simulations show this method is accurate to 0.03% in FA and 0.07% in T(1) for ratios of repetition time to T1 time over the range of 0.01-0.45. We show for the case of brain imaging that it is sufficient to use only one small FA spoiled gradient-echo acquisition, which results in reduced spoiling requirements and a significant scan time reduction compared to the original variable FA method. In vivo validation yielded high-quality 3D T(1) maps and T(1) measurements within 10% of previously published values and within a clinically acceptable scan time. The variable FA-actual FA imaging method will increase the accuracy and clinical feasibility of many quantitative MRI methods requiring T(1)/B(1) mapping such as dynamic contrast enhanced perfusion and quantitative magnetization transfer imaging.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 22139819      PMCID: PMC3295910          DOI: 10.1002/mrm.23199

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  35 in total

1.  A fast 3D look-locker method for volumetric T1 mapping.

Authors:  E Henderson; G McKinnon; T Y Lee; B K Rutt
Journal:  Magn Reson Imaging       Date:  1999-10       Impact factor: 2.546

2.  Sensitivity encoding as a means of enhancing the SNR efficiency in steady-state MRI.

Authors:  Markus Weiger; Peter Boesiger; Paul R Hilfiker; Dominik Weishaupt; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2005-01       Impact factor: 4.668

3.  Fast high-resolution T1 mapping of the human brain.

Authors:  Ralf Deichmann
Journal:  Magn Reson Med       Date:  2005-07       Impact factor: 4.668

4.  Factors influencing flip angle mapping in MRI: RF pulse shape, slice-select gradients, off-resonance excitation, and B0 inhomogeneities.

Authors:  Jinghua Wang; Weihua Mao; Maolin Qiu; Michael B Smith; R Todd Constable
Journal:  Magn Reson Med       Date:  2006-08       Impact factor: 4.668

5.  Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field.

Authors:  Vasily L Yarnykh
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

6.  Rapid high-resolution T(1) mapping by variable flip angles: accurate and precise measurements in the presence of radiofrequency field inhomogeneity.

Authors:  Hai-Ling Margaret Cheng; Graham A Wright
Journal:  Magn Reson Med       Date:  2006-03       Impact factor: 4.668

7.  Saturated double-angle method for rapid B1+ mapping.

Authors:  Charles H Cunningham; John M Pauly; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2006-06       Impact factor: 4.668

8.  Fast 3D radiofrequency field mapping using echo-planar imaging.

Authors:  F Jiru; U Klose
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

9.  Optimized and combined T1 and B1 mapping technique for fast and accurate T1 quantification in contrast-enhanced abdominal MRI.

Authors:  Reto Treier; Andreas Steingoetter; Michael Fried; Werner Schwizer; Peter Boesiger
Journal:  Magn Reson Med       Date:  2007-03       Impact factor: 4.668

10.  High-resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2.

Authors:  Sean C L Deoni; Terry M Peters; Brian K Rutt
Journal:  Magn Reson Med       Date:  2005-01       Impact factor: 4.668

View more
  24 in total

1.  Magnetization transfer in magnetic resonance fingerprinting.

Authors:  Tom Hilbert; Ding Xia; Kai Tobias Block; Zidan Yu; Riccardo Lattanzi; Daniel K Sodickson; Tobias Kober; Martijn A Cloos
Journal:  Magn Reson Med       Date:  2019-11-25       Impact factor: 4.668

2.  Accurate T1 mapping of short T2 tissues using a three-dimensional ultrashort echo time cones actual flip angle imaging-variable repetition time (3D UTE-Cones AFI-VTR) method.

Authors:  Ya-Jun Ma; Xing Lu; Michael Carl; Yanchun Zhu; Nikolaus M Szeverenyi; Graeme M Bydder; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2018-01-03       Impact factor: 4.668

3.  More than BOLD: Dual-spin populations create functional contrast.

Authors:  Amanda J Taylor; Jung H Kim; Vimal Singh; Elizabeth J Halfen; Josef Pfeuffer; David Ress
Journal:  Magn Reson Med       Date:  2019-08-18       Impact factor: 4.668

4.  Propagation of error from parameter constraints in quantitative MRI: Example application of multiple spin echo T2 mapping.

Authors:  Christopher L Lankford; Mark D Does
Journal:  Magn Reson Med       Date:  2017-04-20       Impact factor: 4.668

5.  Slice profile and B1 corrections in 2D magnetic resonance fingerprinting.

Authors:  Dan Ma; Simone Coppo; Yong Chen; Debra F McGivney; Yun Jiang; Shivani Pahwa; Vikas Gulani; Mark A Griswold
Journal:  Magn Reson Med       Date:  2017-01-11       Impact factor: 4.668

6.  Measurements of cerebral blood volume using quantitative susceptibility mapping, R2 * relaxometry, and ferumoxytol-enhanced MRI.

Authors:  Leonardo A Rivera-Rivera; Tilman Schubert; Kevin M Johnson
Journal:  NMR Biomed       Date:  2019-09-04       Impact factor: 4.044

7.  Whole knee joint T1 values measured in vivo at 3T by combined 3D ultrashort echo time cones actual flip angle and variable flip angle methods.

Authors:  Ya-Jun Ma; Wei Zhao; Lidi Wan; Tan Guo; Adam Searleman; Hyungseok Jang; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2018-11-16       Impact factor: 4.668

8.  Fast 3D magnetic resonance fingerprinting for a whole-brain coverage.

Authors:  Dan Ma; Yun Jiang; Yong Chen; Debra McGivney; Bhairav Mehta; Vikas Gulani; Mark Griswold
Journal:  Magn Reson Med       Date:  2017-08-22       Impact factor: 4.668

9.  Improved encoding pulses for Bloch-Siegert B1(+) mapping.

Authors:  Marcin Jankiewicz; John C Gore; William A Grissom
Journal:  J Magn Reson       Date:  2012-11-17       Impact factor: 2.229

10.  Accelerating MR parameter mapping using sparsity-promoting regularization in parametric dimension.

Authors:  Julia V Velikina; Andrew L Alexander; Alexey Samsonov
Journal:  Magn Reson Med       Date:  2012-12-04       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.