A fast 3D look-locker method for volumetric T1 mapping.

E Henderson1, G McKinnon, T Y Lee, B K Rutt.   

Abstract

We introduce a fast technique, based on the principles of the 2D Look-Locker T1 measurement scheme, to rapidly acquire the data for accurate maps of T1 in three dimensions. The acquisition time has been shortened considerably by segmenting the acquisition of the k(y) phase encode lines. Using this technique, the data for a 256 x 128 x 32 volumetric T1 measurement can be acquired in 7.6 min. T1 measurements made in phantoms with T1s between 200 and 1200 ms had an accuracy of 4% and a reproducibility of 3.5%. Measurements of T1 made in normal brain using the fast 3D sequence corresponded well with inversion-recovery fast spin-echo measurements.

Mesh:

Year:  1999        PMID: 10499678     DOI: 10.1016/s0730-725x(99)00025-9

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  41 in total

1.  Ultrafast compartmentalized relaxation time mapping with linear algebraic modeling.

Authors:  Yi Zhang; Xiaoyang Liu; Jinyuan Zhou; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2017-04-11       Impact factor: 4.668

Review 2.  Inferring brain tissue composition and microstructure via MR relaxometry.

Authors:  Mark D Does
Journal:  Neuroimage       Date:  2018-01-02       Impact factor: 6.556

3.  Rapid high-resolution three-dimensional mapping of T1 and age-dependent variations in the non-human primate brain using magnetization-prepared rapid gradient-echo (MPRAGE) sequence.

Authors:  Junjie V Liu; Nicholas A Bock; Afonso C Silva
Journal:  Neuroimage       Date:  2011-03-03       Impact factor: 6.556

4.  Fast T1 and T2 mapping methods: the zoomed U-FLARE sequence compared with EPI and snapshot-FLASH for abdominal imaging at 11.7 Tesla.

Authors:  Géraldine Pastor; María Jiménez-González; Sandra Plaza-García; Marta Beraza; Torsten Reese
Journal:  MAGMA       Date:  2017-01-09       Impact factor: 2.310

5.  Estimating T1 from multichannel variable flip angle SPGR sequences.

Authors:  Joshua D Trzasko; Petrice M Mostardi; Stephen J Riederer; Armando Manduca
Journal:  Magn Reson Med       Date:  2012-07-17       Impact factor: 4.668

6.  Comparison of T1 mapping and fixed T1 method for dynamic contrast-enhanced MRI perfusion in brain gliomas.

Authors:  G M Conte; L Altabella; A Castellano; V Cuccarini; A Bizzi; M Grimaldi; A Costa; M Caulo; A Falini; N Anzalone
Journal:  Eur Radiol       Date:  2019-04-10       Impact factor: 5.315

7.  Optimized inversion-time schedules for quantitative T1 measurements based on high-resolution multi-inversion EPI.

Authors:  Ouri Cohen; Jonathan R Polimeni
Journal:  Magn Reson Med       Date:  2017-08-27       Impact factor: 4.668

8.  Automated patient-specific optimization of three-dimensional double-inversion recovery magnetic resonance imaging.

Authors:  Refaat E Gabr; Xiaojun Sun; Amol S Pednekar; Ponnada A Narayana
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

9.  Statistical estimation of T1 relaxation times using conventional magnetic resonance imaging.

Authors:  Amanda F Mejia; Elizabeth M Sweeney; Blake Dewey; Govind Nair; Pascal Sati; Colin Shea; Daniel S Reich; Russell T Shinohara
Journal:  Neuroimage       Date:  2015-12-28       Impact factor: 6.556

10.  Quantitative evaluation of dual-flip-angle T1 mapping on DCE-MRI kinetic parameter estimation in head and neck.

Authors:  Jing Yuan; Steven Kwok Keung Chow; David Ka Wai Yeung; Anil T Ahuja; Ann D King
Journal:  Quant Imaging Med Surg       Date:  2012-12
View more