Literature DB >> 16450365

Rapid high-resolution T(1) mapping by variable flip angles: accurate and precise measurements in the presence of radiofrequency field inhomogeneity.

Hai-Ling Margaret Cheng1, Graham A Wright.   

Abstract

Rapid 3D mapping of T(1) relaxation times is valuable in diverse clinical applications. Recently, the variable flip angle (VFA) spoiled gradient recalled echo approach was shown to be a practical alternative to conventional methods, providing better precision and speed. However, the method is known to be sensitive to transmit field (B(1) (+)) inhomogeneity and can result in significant systematic errors in T(1) estimates, especially at high field strengths. The main challenge is to improve the accuracy of the VFA approach without sacrificing speed. In this article, the VFA method was optimized for both accuracy and precision by considering the influence of imperfect transmit fields, noise bias, and selection of flip angles. An analytic solution was developed for systematic B(1) (+)-induced T(1) errors and allows simple correction of T(1) measurements acquired with any imaging parameters. A noise threshold was also identified and provided a guideline for avoiding T(1) biases. Finally, it was shown that three flip angles were the most efficient for maintaining accuracy and high precision over large ranges of T(1). A rapid B(1) (+) mapping sequence was employed in all phantom experiments and high-field in vivo brain scans. Experimental results confirmed the theory and validated the accuracy of the proposed method. Magn Reson Med, 2006. (c) 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 16450365     DOI: 10.1002/mrm.20791

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  114 in total

1.  Low rank alternating direction method of multipliers reconstruction for MR fingerprinting.

Authors:  Jakob Assländer; Martijn A Cloos; Florian Knoll; Daniel K Sodickson; Jürgen Hennig; Riccardo Lattanzi
Journal:  Magn Reson Med       Date:  2017-03-05       Impact factor: 4.668

2.  Mapping of low flip angles in magnetic resonance.

Authors:  Fabien Balezeau; Pierre-Antoine Eliat; Alejandro Bordelois Cayamo; Hervé Saint-Jalmes
Journal:  Phys Med Biol       Date:  2011-09-23       Impact factor: 3.609

3.  Optimized T1- and T2-weighted volumetric brain imaging as a diagnostic tool in very preterm neonates.

Authors:  Revital Nossin-Manor; Andrew D Chung; Drew Morris; João P Soares-Fernandes; Bejoy Thomas; Hai-Ling M Cheng; Hilary E A Whyte; Margot J Taylor; John G Sled; Manohar M Shroff
Journal:  Pediatr Radiol       Date:  2010-12-16

4.  Flexible and efficient optimization of quantitative sequences using automatic differentiation of Bloch simulations.

Authors:  Philip K Lee; Lauren E Watkins; Timothy I Anderson; Guido Buonincontri; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2019-05-26       Impact factor: 4.668

5.  To measure T1 of short T2 species using an inversion recovery prepared three-dimensional ultrashort echo time (3D IR-UTE) method: A phantom study.

Authors:  Zhao Wei; Ya-Jun Ma; Hyungseok Jang; Wenhui Yang; Jiang Du
Journal:  J Magn Reson       Date:  2020-04-13       Impact factor: 2.229

6.  Accurate T1 mapping of short T2 tissues using a three-dimensional ultrashort echo time cones actual flip angle imaging-variable repetition time (3D UTE-Cones AFI-VTR) method.

Authors:  Ya-Jun Ma; Xing Lu; Michael Carl; Yanchun Zhu; Nikolaus M Szeverenyi; Graeme M Bydder; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2018-01-03       Impact factor: 4.668

7.  Preclinical hyperpolarized 129 Xe MRI: ventilation and T2 * mapping in mouse lungs at 7 T using multi-echo flyback UTE.

Authors:  Peter J Niedbalski; Alexander S Cochran; Teckla G Akinyi; Robert P Thomen; Elizabeth M Fugate; Diana M Lindquist; Ronald G Pratt; Zackary I Cleveland
Journal:  NMR Biomed       Date:  2020-04-14       Impact factor: 4.044

8.  Whole-lesion histogram and texture analyses of breast lesions on inline quantitative DCE mapping with CAIPIRINHA-Dixon-TWIST-VIBE.

Authors:  Kun Sun; Hong Zhu; Weimin Chai; Ying Zhan; Dominik Nickel; Robert Grimm; Caixia Fu; Fuhua Yan
Journal:  Eur Radiol       Date:  2019-08-01       Impact factor: 5.315

9.  Four-dimensional transcatheter intraarterial perfusion (TRIP)-MRI for monitoring liver tumor embolization in VX2 rabbits.

Authors:  Dingxin Wang; Sumeet Virmani; Richard Tang; Barbara Szolc-Kowalska; Gayle Woloschak; Reed A Omary; Andrew C Larson
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

10.  Linear least-squares method for unbiased estimation of T1 from SPGR signals.

Authors:  Lin-Ching Chang; Cheng Guan Koay; Peter J Basser; Carlo Pierpaoli
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.