Literature DB >> 15690526

High-resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2.

Sean C L Deoni1, Terry M Peters, Brian K Rutt.   

Abstract

Variations in the intrinsic T(1) and T(2) relaxation times have been implicated in numerous neurologic conditions. Unfortunately, the low resolution and long imaging time associated with conventional methods have prevented T(1) and T(2) mapping from becoming part of routine clinical evaluation. In this study, the clinical applicability of the DESPOT1 and DESPOT2 imaging methods for high-resolution, whole-brain, T(1) and T(2) mapping was investigated. In vivo, 1-mm(3) isotropic whole-brain T(1) and T(2) maps of six healthy volunteers were acquired at 1.5 T with an imaging time of <17 min each. Isotropic maps (0.34 mm(3)) of one volunteer were also acquired (time <21 min). Average signal-to-noise within the 1-mm(3) T(1) and T(2) maps was approximately 20 and approximately 14, respectively, with average repeatability standard deviations of 46.7 ms and 6.7 ms. These results demonstrate the clinical feasibility of the methods in the study of neurologic disease. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 15690526     DOI: 10.1002/mrm.20314

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  135 in total

1.  Novel whole brain segmentation and volume estimation using quantitative MRI.

Authors:  J West; J B M Warntjes; P Lundberg
Journal:  Eur Radiol       Date:  2011-11-24       Impact factor: 5.315

2.  Generation of individualized thalamus target maps by using statistical shape models and thalamocortical tractography.

Authors:  A Jakab; R Blanc; E L Berényi; G Székely
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-14       Impact factor: 3.825

3.  Assessment of Blood Hemodynamics by USPIO-Induced R(1) Changes in MRI of Murine Colon Carcinoma.

Authors:  Giulio Gambarota; H W M van Laarhoven; M Philippens; W J M Peeters; P Rijken; A van der Kogel; C J A Punt; A Heerschap
Journal:  Appl Magn Reson       Date:  2010-03-28       Impact factor: 0.831

4.  Incorporation of nonzero echo times in the SPGR and bSSFP signal models used in mcDESPOT.

Authors:  Mustapha Bouhrara; Richard G Spencer
Journal:  Magn Reson Med       Date:  2015-09-26       Impact factor: 4.668

5.  Quantitative MRI for Analysis of Active Multiple Sclerosis Lesions without Gadolinium-Based Contrast Agent.

Authors:  I Blystad; I Håkansson; A Tisell; J Ernerudh; Ö Smedby; P Lundberg; E-M Larsson
Journal:  AJNR Am J Neuroradiol       Date:  2015-10-15       Impact factor: 3.825

6.  H.M.'s contributions to neuroscience: a review and autopsy studies.

Authors:  Jean C Augustinack; André J W van der Kouwe; David H Salat; Thomas Benner; Allison A Stevens; Jacopo Annese; Bruce Fischl; Matthew P Frosch; Suzanne Corkin
Journal:  Hippocampus       Date:  2014-09-23       Impact factor: 3.899

7.  Accurate T1 mapping of short T2 tissues using a three-dimensional ultrashort echo time cones actual flip angle imaging-variable repetition time (3D UTE-Cones AFI-VTR) method.

Authors:  Ya-Jun Ma; Xing Lu; Michael Carl; Yanchun Zhu; Nikolaus M Szeverenyi; Graeme M Bydder; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2018-01-03       Impact factor: 4.668

8.  Fast radio-frequency enforced steady state (FRESS) spin echo MRI for quantitative T2 mapping: minimizing the apparent repetition time (TR) dependence for fast T2 measurement.

Authors:  Jerry S Cheung; Enfeng Wang; XiaoAn Zhang; Emiri Mandeville; Eng H Lo; A Gregory Sorensen; Phillip Zhe Sun
Journal:  NMR Biomed       Date:  2011-07-14       Impact factor: 4.044

9.  Linear least-squares method for unbiased estimation of T1 from SPGR signals.

Authors:  Lin-Ching Chang; Cheng Guan Koay; Peter J Basser; Carlo Pierpaoli
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

10.  Joint arterial input function and tracer kinetic parameter estimation from undersampled dynamic contrast-enhanced MRI using a model consistency constraint.

Authors:  Yi Guo; Sajan Goud Lingala; Yannick Bliesener; R Marc Lebel; Yinghua Zhu; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.