Factors influencing flip angle mapping in MRI: RF pulse shape, slice-select gradients, off-resonance excitation, and B0 inhomogeneities.

Jinghua Wang1, Weihua Mao, Maolin Qiu, Michael B Smith, R Todd Constable.   

Abstract

To understand the various effects that influence actual flip angles, and correct for these effects, it is important to precisely quantify the MRI parameters (such as T1, T2, and perfusion). In this paper actual flip angle maps are calculated using a conventional gradient-echo (GRE) sequence with different radiofrequency (RF) pulse shapes (Gaussian, sinc, and truncated-sinc), slice-selection gradients, off-resonance excitations, and B0 field inhomogeneities. The experimental results demonstrate that RF pulse shapes significantly affect the flip angle distribution and calibration factors. Off-resonance RF excitations, B0 nonuniformities, and slice-selection gradients can lead to degradations in the signal intensities of the images used to map the flip angle, and potentially introduce a bias and increased variance in the measured flip angles. Copyright 2006 Wiley-Liss, Inc.

Mesh:

Year:  2006        PMID: 16773653     DOI: 10.1002/mrm.20947

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  23 in total

Review 1.  Advancing imaging technologies for patients with spinal pain: with a focus on whiplash injury.

Authors:  James M Elliott; Mark J Hancock; Rebecca J Crawford; Andrew C Smith; David M Walton
Journal:  Spine J       Date:  2017-07-31       Impact factor: 4.166

2.  B1 mapping by Bloch-Siegert shift.

Authors:  Laura I Sacolick; Florian Wiesinger; Ileana Hancu; Mika W Vogel
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

3.  Fast T1 and T2 mapping methods: the zoomed U-FLARE sequence compared with EPI and snapshot-FLASH for abdominal imaging at 11.7 Tesla.

Authors:  Géraldine Pastor; María Jiménez-González; Sandra Plaza-García; Marta Beraza; Torsten Reese
Journal:  MAGMA       Date:  2017-01-09       Impact factor: 2.310

4.  Slice profile and B1 corrections in 2D magnetic resonance fingerprinting.

Authors:  Dan Ma; Simone Coppo; Yong Chen; Debra F McGivney; Yun Jiang; Shivani Pahwa; Vikas Gulani; Mark A Griswold
Journal:  Magn Reson Med       Date:  2017-01-11       Impact factor: 4.668

5.  An in vivo comparison of the DREAM sequence with current RF shim technology.

Authors:  Kay Nehrke; Alois M Sprinkart; Peter Börnert
Journal:  MAGMA       Date:  2014-08-10       Impact factor: 2.310

6.  Targeted radiofrequency field mapping using 3D reduced field-of-view-catalyzed double-angle method.

Authors:  Dingxin Wang; Sven Zuehlsdorff; Reed A Omary; Andrew C Larson
Journal:  Magn Reson Imaging       Date:  2011-06-25       Impact factor: 2.546

7.  Simultaneous variable flip angle-actual flip angle imaging method for improved accuracy and precision of three-dimensional T1 and B1 measurements.

Authors:  Samuel A Hurley; Vasily L Yarnykh; Kevin M Johnson; Aaron S Field; Andrew L Alexander; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

8.  Steady-state double-angle method for rapid B1 mapping.

Authors:  Mustapha Bouhrara; Richard G Spencer
Journal:  Magn Reson Med       Date:  2019-03-03       Impact factor: 4.668

9.  Rapid 3D radiofrequency field mapping using catalyzed double-angle method.

Authors:  Dingxin Wang; Sven Zuehlsdorff; Andrew C Larson
Journal:  NMR Biomed       Date:  2009-10       Impact factor: 4.044

10.  Use of cardiac output to improve measurement of input function in quantitative dynamic contrast-enhanced MRI.

Authors:  Jeff L Zhang; Henry Rusinek; Louisa Bokacheva; Qun Chen; Pippa Storey; Vivian S Lee
Journal:  J Magn Reson Imaging       Date:  2009-09       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.