Improved encoding pulses for Bloch-Siegert B1(+) mapping.

Marcin Jankiewicz1, John C Gore, William A Grissom.   

Abstract

A new family of optimized encoding pulses for Bloch-Siegert (BS) |B(1)(+)| mapping is introduced, as well as an algorithm to design them. The pulses are designed by numerical maximization of BS sequence sensitivity, subject to constraints that ensure low on-resonance excitation. The pulses are in all cases characterized by a constant envelope and U-shaped frequency sweep. They are validated in simulations, 7T in vivo experiments, and an experiment to measure their on-resonance excitation, and are compared to a Fermi pulse conventionally used in the BS method. The pulses are shown to produce larger phase shifts in a shorter time and with lower on-resonance excitation than the Fermi pulse, which results in lower SAR and improved |B(1)(+)| accuracy in areas of the body with large main field inhomogeneities.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23220183      PMCID: PMC3561618          DOI: 10.1016/j.jmr.2012.11.004

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  12 in total

1.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

2.  Parallel excitation with an array of transmit coils.

Authors:  Yudong Zhu
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

3.  Rapid in vivo proton shimming.

Authors:  E Schneider; G Glover
Journal:  Magn Reson Med       Date:  1991-04       Impact factor: 4.668

4.  Optimal radiofrequency and gradient spoiling for improved accuracy of T1 and B1 measurements using fast steady-state techniques.

Authors:  Vasily L Yarnykh
Journal:  Magn Reson Med       Date:  2010-06       Impact factor: 4.668

5.  Spatial domain method for the design of RF pulses in multicoil parallel excitation.

Authors:  William Grissom; Chun-yu Yip; Zhenghui Zhang; V Andrew Stenger; Jeffrey A Fessler; Douglas C Noll
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

6.  Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field.

Authors:  Vasily L Yarnykh
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

7.  Saturated double-angle method for rapid B1+ mapping.

Authors:  Charles H Cunningham; John M Pauly; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2006-06       Impact factor: 4.668

8.  A homogeneity correction method for magnetic resonance imaging with time-varying gradients.

Authors:  D C Noll; C H Meyer; J M Pauly; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

9.  A phase-sensitive method of flip angle mapping.

Authors:  Glen R Morrell
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

10.  Simultaneous variable flip angle-actual flip angle imaging method for improved accuracy and precision of three-dimensional T1 and B1 measurements.

Authors:  Samuel A Hurley; Vasily L Yarnykh; Kevin M Johnson; Aaron S Field; Andrew L Alexander; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

View more
  6 in total

1.  gr-MRI: A software package for magnetic resonance imaging using software defined radios.

Authors:  Christopher J Hasselwander; Zhipeng Cao; William A Grissom
Journal:  J Magn Reson       Date:  2016-07-01       Impact factor: 2.229

2.  Motion-robust cardiac B1+ mapping at 3T using interleaved bloch-siegert shifts.

Authors:  Sebastian Weingärtner; Fabian Zimmer; Gregory J Metzger; Kâmil Uğurbil; Pierre-Francois Van de Moortele; Mehmet Akçakaya
Journal:  Magn Reson Med       Date:  2016-09-07       Impact factor: 4.668

3.  Tailored spiral in-out spectral-spatial water suppression pulses for magnetic resonance spectroscopic imaging.

Authors:  Jun Ma; Carrie Wismans; Zhipeng Cao; Dennis W J Klomp; Jannie P Wijnen; William A Grissom
Journal:  Magn Reson Med       Date:  2017-03-31       Impact factor: 4.668

4.  Low peak power multiband spokes pulses for B1 (+) inhomogeneity-compensated simultaneous multislice excitation in high field MRI.

Authors:  Anuj Sharma; Roland Bammer; V Andrew Stenger; William A Grissom
Journal:  Magn Reson Med       Date:  2014-09-09       Impact factor: 4.668

5.  Bloch-Siegert B1-Mapping Improves Accuracy and Precision of Longitudinal Relaxation Measurements in the Breast at 3 T.

Authors:  Jennifer G Whisenant; Richard D Dortch; William Grissom; Hakmook Kang; Lori R Arlinghaus; Thomas E Yankeelov
Journal:  Tomography       Date:  2016-12

6.  Quantitative Magnetization Transfer Imaging of the Breast at 3.0 T: Reproducibility in Healthy Volunteers.

Authors:  Lori R Arlinghaus; Richard D Dortch; Jennifer G Whisenant; Hakmook Kang; Richard G Abramson; Thomas E Yankeelov
Journal:  Tomography       Date:  2016-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.