Literature DB >> 17191242

Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field.

Vasily L Yarnykh1.   

Abstract

A new method has been developed for fast image-based measurements of the transmitted radiofrequency (RF) field. The method employs an actual flip-angle imaging (AFI) pulse sequence that consists of two identical RF pulses followed by two delays of different duration (TR(1) < TR(2)). After each pulse, a gradient-echo (GRE) signal is acquired. It has been shown theoretically and experimentally that if delays TR(1) and TR(2) are sufficiently short and the transverse magnetization is completely spoiled, the ratio r = S(2)/S(1) of signal intensities S(1) and S(2), acquired at the beginning of the time intervals TR(1) and TR(2), depends on the flip angle (FA) of applied pulses as r = (1 + n * cos(FA))/(n + cos(FA)), where n = TR(2)/TR(1). The method allows fast 3D implementation and provides accurate B(1) measurements that are highly insensitive to T(1). The unique feature of the AFI method is that it uses a pulsed steady-state signal acquisition. This overcomes the limitation of previous methods that required long relaxation delays between sequence repetitions. The method has been shown to be useful for time-efficient whole-body B(1) mapping and correction of T(1) maps obtained using a variable FA technique in the presence of nonuniform RF excitation.

Mesh:

Year:  2007        PMID: 17191242     DOI: 10.1002/mrm.21120

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  339 in total

1.  High-resolution imaging of distinct human corpus callosum microstructure and topography of structural connectivity to cortices at high field.

Authors:  Byeong-Yeul Lee; Xiao-Hong Zhu; Xiufeng Li; Wei Chen
Journal:  Brain Struct Funct       Date:  2018-12-03       Impact factor: 3.270

2.  Composite RF pulses for B1+-insensitive volume excitation at 7 Tesla.

Authors:  Jay Moore; Marcin Jankiewicz; Huairen Zeng; Adam W Anderson; John C Gore
Journal:  J Magn Reson       Date:  2010-04-10       Impact factor: 2.229

3.  T₂ -weighted MRI of post-infarct myocardial edema in mice.

Authors:  Ronald J Beyers; R Scott Smith; Yaqin Xu; Bryan A Piras; Michael Salerno; Stuart S Berr; Craig H Meyer; Christopher M Kramer; Brent A French; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2011-05-31       Impact factor: 4.668

4.  Removal of cerebrospinal fluid partial volume effects in quantitative magnetization transfer imaging using a three-pool model with nonexchanging water component.

Authors:  Pouria Mossahebi; Andrew L Alexander; Aaron S Field; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2014-11-13       Impact factor: 4.668

5.  Quantifying cortical bone water in vivo by three-dimensional ultra-short echo-time MRI.

Authors:  Hamidreza Saligheh Rad; Shing Chun Benny Lam; Jeremy F Magland; Henry Ong; Cheng Li; Hee Kwon Song; James Love; Felix W Wehrli
Journal:  NMR Biomed       Date:  2011-01-28       Impact factor: 4.044

6.  Mapping of low flip angles in magnetic resonance.

Authors:  Fabien Balezeau; Pierre-Antoine Eliat; Alejandro Bordelois Cayamo; Hervé Saint-Jalmes
Journal:  Phys Med Biol       Date:  2011-09-23       Impact factor: 3.609

7.  Rotator cuff tendon assessment using magic-angle insensitive 3D ultrashort echo time cones magnetization transfer (UTE-Cones-MT) imaging and modeling with histological correlation.

Authors:  Yanchun Zhu; Xin Cheng; Yajun Ma; Jonathan H Wong; Yaoqin Xie; Jiang Du; Eric Y Chang
Journal:  J Magn Reson Imaging       Date:  2017-12-08       Impact factor: 4.813

8.  3D Cine Magnetic Resonance Imaging of Rat Lung ARDS using Gradient-modulated SWIFT with Retrospective Respiratory Gating.

Authors:  Naoharu Kobayashi; Jianxun Lei; Lynn Utecht; Michael Garwood; David Ingbar; Maneesh Bhargava
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-02-21

9.  T1 weighted brain images at 7 Tesla unbiased for Proton Density, T2* contrast and RF coil receive B1 sensitivity with simultaneous vessel visualization.

Authors:  Pierre-François Van de Moortele; Edwards J Auerbach; Cheryl Olman; Essa Yacoub; Kâmil Uğurbil; Steen Moeller
Journal:  Neuroimage       Date:  2009-02-20       Impact factor: 6.556

Review 10.  Magnetic-resonance-based electrical properties tomography: a review.

Authors:  Xiaotong Zhang; Jiaen Liu; Bin He
Journal:  IEEE Rev Biomed Eng       Date:  2014
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.