Literature DB >> 15690517

Sensitivity encoding as a means of enhancing the SNR efficiency in steady-state MRI.

Markus Weiger1, Peter Boesiger, Paul R Hilfiker, Dominik Weishaupt, Klaas P Pruessmann.   

Abstract

Sensitivity encoding (SENSE) with a receiver coil array is typically used as a means of reducing the scan time in MRI. The speed benefit usually comes at some expense in terms of the signal-to-noise ratio (SNR) efficiency, which has been notorious as the main downside of SENSE and parallel MRI in general. In this work it is shown that in steady-state gradient-echo imaging the parallel approach may as well be used to increase the SNR efficiency. The basic idea is to balance reduced phase encoding by increasing the repetition time. In this fashion both the acquisition duty cycle and the steady-state magnetization can be enhanced, resulting in considerable net gains in SNR yield. It is argued that the reduction factor in parallel imaging is essentially an additional degree of freedom in optimizing the SNR. The optimal SENSE factor depends on scan, tissue, and hardware parameters, assuming values up to 3.0 and higher. The achievable SNR benefit also depends on the spoiling regime and is most pronounced for RF-spoiled techniques. The proposed mechanism is demonstrated by simulations and phantom experiments, as well as by contrast-enhanced angiography in vivo, achieving an approximate doubling of the SNR efficiency. Copyright 2004 Wiley-Liss, Inc.

Mesh:

Year:  2005        PMID: 15690517     DOI: 10.1002/mrm.20322

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  The Dixon technique and the frequency-selective fat suppression technique in three-dimensional T1 weighted MRI of the liver: a comparison of contrast-to-noise ratios of hepatocellular carcinomas-to-liver.

Authors:  Y Takatsu; T Akasaka; T Miyati
Journal:  Br J Radiol       Date:  2015-04-02       Impact factor: 3.039

2.  OPTIMAL MULTI-CHANNEL TIME-SEQUENTIAL ACQUISITION IN DYNAMIC MRI WITH PARALLEL COILS.

Authors:  Behzad Sharif; Yoram Bresler
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2006

3.  Denoising MRI using spectral subtraction.

Authors:  M Arcan Erturk; Paul A Bottomley; Abdel-Monem M El-Sharkawy
Journal:  IEEE Trans Biomed Eng       Date:  2013-01-10       Impact factor: 4.538

4.  Simultaneous variable flip angle-actual flip angle imaging method for improved accuracy and precision of three-dimensional T1 and B1 measurements.

Authors:  Samuel A Hurley; Vasily L Yarnykh; Kevin M Johnson; Aaron S Field; Andrew L Alexander; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

5.  Practical signal-to-noise ratio quantification for sensitivity encoding: application to coronary MR angiography.

Authors:  Jing Yu; Harsh Agarwal; Matthias Stuber; Michael Schär
Journal:  J Magn Reson Imaging       Date:  2011-06       Impact factor: 4.813

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.