Literature DB >> 21541774

Image quality and dose performance of 80 kV low dose scan protocol in high-pitch spiral coronary CT angiography: feasibility study.

Dan Wang1, Xiu-hua Hu, Shi-zheng Zhang, Run-ze Wu, Su-su Xie, Bin Chen, Qiao-wei Zhang.   

Abstract

To investigate the image quality and dose performance of 80 kV high-pitch spiral (HPS) coronary CT angiography (CCTA). 106 patients consecutively enrolled into prospectively ECG-triggering HPS CCTA (pitch = 3.4) exam using kV/ref. mAs = 80/400, 100/370, and 120/370 when patient BMI was ≤22.5 (n = 40), between 22.5 and 27.5 (n = 53) and >27.5 kg/m² (n = 13). Image quality was assessed per-segment by two observers independently using a 4-point scale (1-excellent, 4-non-diagnosable). Image noise and signal-to-noise ratio (SNR), contrast-to-noise ratio were measured. Diagnostic image quality was obtained in 503 of 507, 687 of 693, 164 of 167 coronary segments in 80, 100, 120 kV groups without significant difference (P = 0.482). The proportions of segments with score 1-4 were not significantly different among three kV groups (all P > 0.05). Image noise were significantly higher in 80 kV group than 100 and 120 groups (P < 0.001), while SNR was not (P = 0.097). The effective dose of 80 kV group (0.36 ± 0.03 mSv) was significantly lower than that of 100 kV group (0.86 ± 0.08 mSv) and 120 kV group (1.77 ± 0.18 mSv). The mean ± SD of HR in all patients was 54.8 ± 5.1 bpm. 80 kV HPS CCTA is feasible for patient with BMI ≤ 22.5 kg/m² which can save 58% dose than 100 kV group, while maintain diagnosable image quality.

Entities:  

Mesh:

Year:  2011        PMID: 21541774     DOI: 10.1007/s10554-011-9822-5

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  23 in total

1.  MDCT of the coronary arteries: feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose.

Authors:  Hicham T Abada; Christophe Larchez; Béatrice Daoud; Anne Sigal-Cinqualbre; Jean-François Paul
Journal:  AJR Am J Roentgenol       Date:  2006-06       Impact factor: 3.959

2.  High-pitch spiral acquisition: a new scan mode for coronary CT angiography.

Authors:  Stephan Achenbach; Mohamed Marwan; Tiziano Schepis; Tobias Pflederer; Herbert Bruder; Thomas Allmendinger; Martin Petersilka; Katharina Anders; Michael Lell; Axel Kuettner; Dieter Ropers; Werner G Daniel; Thomas Flohr
Journal:  J Cardiovasc Comput Tomogr       Date:  2009-02-26

3.  Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose.

Authors:  Paul Stolzmann; Sebastian Leschka; Hans Scheffel; Tobias Krauss; Lotus Desbiolles; André Plass; Michele Genoni; Thomas G Flohr; Simon Wildermuth; Borut Marincek; Hatem Alkadhi
Journal:  Radiology       Date:  2008-10       Impact factor: 11.105

4.  Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience.

Authors:  Márcio Sommer Bittencourt; Bernhard Schmidt; Martin Seltmann; Gerd Muschiol; Dieter Ropers; Werner Günther Daniel; Stephan Achenbach
Journal:  Int J Cardiovasc Imaging       Date:  2010-12-01       Impact factor: 2.357

5.  Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience.

Authors:  Sebastian Leschka; Paul Stolzmann; Lotus Desbiolles; Stephan Baumueller; Robert Goetti; Thomas Schertler; Hans Scheffel; Andre Plass; Volkmar Falk; Gudrun Feuchtner; Borut Marincek; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2009-09-16       Impact factor: 5.315

6.  Radiation dose exposure of computed tomography coronary angiography: comparison of dual-source, 16-slice and 64-slice CT.

Authors:  J Rixe; G Conradi; A Rolf; A Schmermund; A Magedanz; D Erkapic; A Deetjen; C W Hamm; T Dill
Journal:  Heart       Date:  2009-05-28       Impact factor: 5.994

7.  Radiation dose of cardiac dual-source CT: the effect of tailoring the protocol to patient-specific parameters.

Authors:  Hatem Alkadhi; Paul Stolzmann; Hans Scheffel; Lotus Desbiolles; Stephan Baumüller; André Plass; Michele Genoni; Borut Marincek; Sebastian Leschka
Journal:  Eur J Radiol       Date:  2008-10-30       Impact factor: 3.528

8.  Dual-source versus 64-section CT coronary angiography at lower heart rates: comparison of accuracy and radiation dose.

Authors:  Stephan Baumüller; Sebastian Leschka; Lotus Desbiolles; Paul Stolzmann; Hans Scheffel; Burkhardt Seifert; Borut Marincek; Hatem Alkadhi
Journal:  Radiology       Date:  2009-07-08       Impact factor: 11.105

9.  Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography.

Authors:  Andrew J Einstein; Milena J Henzlova; Sanjay Rajagopalan
Journal:  JAMA       Date:  2007-07-18       Impact factor: 56.272

10.  Image quality in a low radiation exposure protocol for retrospectively ECG-gated coronary CT angiography.

Authors:  Tobias Pflederer; Larissa Rudofsky; Dieter Ropers; Sven Bachmann; Mohamed Marwan; Werner G Daniel; Stephan Achenbach
Journal:  AJR Am J Roentgenol       Date:  2009-04       Impact factor: 3.959

View more
  15 in total

Review 1.  Low-dose cardiovascular computed tomography: where are the limits?

Authors:  Paul Schoenhagen; Carla M Thompson; Sandra S Halliburton
Journal:  Curr Cardiol Rep       Date:  2012-02       Impact factor: 2.931

2.  Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol.

Authors:  Moritz H Albrecht; John W Nance; U Joseph Schoepf; Brian E Jacobs; Richard R Bayer; Sheldon E Litwin; Michael A Reynolds; Katharina Otani; Stefanie Mangold; Akos Varga-Szemes; Domenico De Santis; Marwen Eid; Georg Apfaltrer; Christian Tesche; Markus Goeller; Thomas J Vogl; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2017-11-27       Impact factor: 5.315

Review 3.  SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT.

Authors:  Sandra S Halliburton; Suhny Abbara; Marcus Y Chen; Ralph Gentry; Mahadevappa Mahesh; Gilbert L Raff; Leslee J Shaw; Jörg Hausleiter
Journal:  J Cardiovasc Comput Tomogr       Date:  2011 Jul-Aug

4.  Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality.

Authors:  Sei Komatsu; Teruaki Kamata; Atsuko Imai; Tomoki Ohara; Mitsuhiko Takewa; Ryoko Ohe; Kazuaki Miyaji; Junichi Yoshida; Kazuhisa Kodama
Journal:  Int J Cardiovasc Imaging       Date:  2013-02-26       Impact factor: 2.357

5.  Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method.

Authors:  David B Larson
Journal:  Pediatr Radiol       Date:  2014-10-11

6.  Coronary CTA using scout-based automated tube potential and current selection algorithm, with breast displacement results in lower radiation exposure in females compared to males.

Authors:  Harshna Vadvala; Phillip Kim; Thomas Mayrhofer; Oleg Pianykh; Mannudeep Kalra; Udo Hoffmann; Brian Ghoshhajra
Journal:  Cardiovasc Diagn Ther       Date:  2014-12

7.  Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography.

Authors:  Long Jiang Zhang; Yining Wang; U Joseph Schoepf; Felix G Meinel; Richard R Bayer; Li Qi; Jian Cao; Chang Sheng Zhou; Yan E Zhao; Xie Li; Jian Bin Gong; Zhengyu Jin; Guang Ming Lu
Journal:  Eur Radiol       Date:  2015-09-17       Impact factor: 5.315

8.  Optimizing contrast medium injection protocol individually with body weight for high-pitch prospective ECG-triggering coronary CT angiography.

Authors:  Jie Liu; Jianbo Gao; Runze Wu; Yonggao Zhang; Lili Hu; Ping Hou
Journal:  Int J Cardiovasc Imaging       Date:  2013-01-04       Impact factor: 2.357

9.  Comparison of image quality between 70 kVp and 80 kVp: application to paediatric cardiac CT.

Authors:  Sébastien Durand; Jean-François Paul
Journal:  Eur Radiol       Date:  2014-08-31       Impact factor: 5.315

10.  Image quality and required radiation dose for coronary computed tomography angiography using an automatic tube potential selection technique.

Authors:  Ying Wang; Xiaohua Wang; Yan Zhang; Yuliu Lu; Runze Wu; Huishu Yuan
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-29       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.