OBJECTIVES: The objective was to prospectively investigate the diagnostic accuracy of high-pitch (HP) dual-source computed tomography coronary angiography (CTCA) compared with catheter coronary angiography (CCA) for the diagnosis of significant coronary stenoses. METHODS: Thirty-five patients (seven women; mean age 62 ± 8 years) underwent both CTCA and CCA. CTCA was performed with a second-generation dual-source CT system permitting data acquisition at an HP of 3.4. Patients with heart rates >60 bpm were excluded from study enrolment. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a four-point scale (1: excellent to 4: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). CCA served as the standard of reference. Radiation dose values were calculated using the dose-length product. RESULTS: Diagnostic image quality was found in 99% of all segments (455/459). Non-diagnostic image quality occurred in a single patient with a sudden increase in heart rate immediately before and during CTCA. Taking segments with non-evaluative image quality as positive for disease, the sensitivity, specificity and positive and negative predictive values were 94, 96, 80 and 99% per segment and 100, 91, 88 and 100% per patient. The effective radiation dose was on average 0.9 ± 0.1 mSv. CONCLUSION: In patients with heart rates ≤60 bpm, CTCA using the HP mode of the dual-source CT system is associated with high diagnostic accuracy for the assessment of coronary artery stenoses at sub-milli-Sievert doses.
OBJECTIVES: The objective was to prospectively investigate the diagnostic accuracy of high-pitch (HP) dual-source computed tomography coronary angiography (CTCA) compared with catheter coronary angiography (CCA) for the diagnosis of significant coronary stenoses. METHODS: Thirty-five patients (seven women; mean age 62 ± 8 years) underwent both CTCA and CCA. CTCA was performed with a second-generation dual-source CT system permitting data acquisition at an HP of 3.4. Patients with heart rates >60 bpm were excluded from study enrolment. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a four-point scale (1: excellent to 4: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). CCA served as the standard of reference. Radiation dose values were calculated using the dose-length product. RESULTS: Diagnostic image quality was found in 99% of all segments (455/459). Non-diagnostic image quality occurred in a single patient with a sudden increase in heart rate immediately before and during CTCA. Taking segments with non-evaluative image quality as positive for disease, the sensitivity, specificity and positive and negative predictive values were 94, 96, 80 and 99% per segment and 100, 91, 88 and 100% per patient. The effective radiation dose was on average 0.9 ± 0.1 mSv. CONCLUSION: In patients with heart rates ≤60 bpm, CTCA using the HP mode of the dual-source CT system is associated with high diagnostic accuracy for the assessment of coronary artery stenoses at sub-milli-Sievert doses.
Authors: W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe Journal: Circulation Date: 1975-04 Impact factor: 29.690
Authors: Sebastian Leschka; Hans Scheffel; Lotus Desbiolles; Andre Plass; Oliver Gaemperli; Ines Valenta; Lars Husmann; Thomas G Flohr; Michele Genoni; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi Journal: Invest Radiol Date: 2007-08 Impact factor: 6.016
Authors: Stephan Achenbach; Mohamed Marwan; Tiziano Schepis; Tobias Pflederer; Herbert Bruder; Thomas Allmendinger; Martin Petersilka; Katharina Anders; Michael Lell; Axel Kuettner; Dieter Ropers; Werner G Daniel; Thomas Flohr Journal: J Cardiovasc Comput Tomogr Date: 2009-02-26
Authors: Paul Stolzmann; Sebastian Leschka; Hans Scheffel; Tobias Krauss; Lotus Desbiolles; André Plass; Michele Genoni; Thomas G Flohr; Simon Wildermuth; Borut Marincek; Hatem Alkadhi Journal: Radiology Date: 2008-10 Impact factor: 11.105
Authors: Nico R Mollet; Filippo Cademartiri; Carlos A G van Mieghem; Giuseppe Runza; Eugène P McFadden; Timo Baks; Patrick W Serruys; Gabriel P Krestin; Pim J de Feyter Journal: Circulation Date: 2005-10-03 Impact factor: 29.690
Authors: Francesca Pugliese; Nico R A Mollet; Giuseppe Runza; Carlos van Mieghem; Willem B Meijboom; Patrizia Malagutti; Timo Baks; Gabriel P Krestin; Pim J deFeyter; Filippo Cademartiri Journal: Eur Radiol Date: 2005-11-16 Impact factor: 5.315
Authors: Thorsten R C Johnson; Konstantin Nikolaou; Stephanie Busch; Alexander W Leber; Alexander Becker; Bernd J Wintersperger; Carsten Rist; Andreas Knez; Maximilian F Reiser; Christoph R Becker Journal: Invest Radiol Date: 2007-10 Impact factor: 6.016
Authors: Ulrike Ropers; Dieter Ropers; Tobias Pflederer; Katharina Anders; Axel Kuettner; Nikolaos I Stilianakis; Sei Komatsu; Willi Kalender; Werner Bautz; Werner G Daniel; Stephan Achenbach Journal: J Am Coll Cardiol Date: 2007-12-18 Impact factor: 24.094
Authors: Paul Stolzmann; Christopher L Schlett; Pal Maurovich-Horvat; Akiko Maehara; Shixin Ma; Hans Scheffel; Leif-Christopher Engel; Mihály Károlyi; Gary S Mintz; Udo Hoffmann Journal: Eur Radiol Date: 2012-05-24 Impact factor: 5.315
Authors: Christoph Karlo; Sebastian Leschka; Robert Paul Goetti; Gudrun Feuchtner; Lotus Desbiolles; Paul Stolzmann; Andre Plass; Volkmar Falk; Borut Marincek; Hatem Alkadhi; Stephan Baumüller Journal: Eur Radiol Date: 2010-07-31 Impact factor: 5.315
Authors: Stefan C Saur; Hatem Alkadhi; Paul Stolzmann; Stephan Baumüller; Sebastian Leschka; Hans Scheffel; Lotus Desbiolles; Thomas J Fuchs; Gábor Székely; Philippe C Cattin Journal: Eur Radiol Date: 2010-01-30 Impact factor: 5.315
Authors: Boris Schell; Ralf W Bauer; Thomas Lehnert; J Matthias Kerl; Markus Hambek; Angelika May; Thomas J Vogl; Martin G Mack Journal: Eur Radiol Date: 2010-07-20 Impact factor: 5.315
Authors: Aleksander Kosmala; Bernhard Petritsch; Andreas Max Weng; Thorsten Alexander Bley; Tobias Gassenmaier Journal: Eur Radiol Date: 2018-11-30 Impact factor: 5.315
Authors: Long Jiang Zhang; Yining Wang; U Joseph Schoepf; Felix G Meinel; Richard R Bayer; Li Qi; Jian Cao; Chang Sheng Zhou; Yan E Zhao; Xie Li; Jian Bin Gong; Zhengyu Jin; Guang Ming Lu Journal: Eur Radiol Date: 2015-09-17 Impact factor: 5.315