Literature DB >> 23288418

Optimizing contrast medium injection protocol individually with body weight for high-pitch prospective ECG-triggering coronary CT angiography.

Jie Liu1, Jianbo Gao, Runze Wu, Yonggao Zhang, Lili Hu, Ping Hou.   

Abstract

To individually optimize contrast medium protocol for high-pitch prospective ECG-triggering coronary CT angiography using body weight. Ninety patients undergoing high-pitch coronary CT angiography were randomly assigned to 3 contrast medium injection protocols with bolus tracking technique: Group A, 0.7 ml CM per kg patient weight (ml/kg); Group B, 0.6 ml/kg; Group C, 0.5 ml/kg. Each group had 30 patients. The CT values of superior vena cava (SVC), pulmonary artery (PA), ascending aorta (AA), left atrium (LA), left ventricle (LV), left main artery (LM) and proximal segment of right coronary artery (RCA) were measured. The image quality of coronary artery was evaluated on per-segment basis using a 4-point scale (1-excellent, 4-non-diagnosis). The CT value was not significantly different on AA (p = 0.735), LM (p = 0.764), and proximal segment of RCA (p = 0.991). The CT value was significantly different on SVC, PA, LA and LV (all p < 0.05). The mean image quality score was 1.6 ± 0.1, 1.6 ± 0.1 and 1.6 ± 0.1 (p = 0.217). The volume of CM was 47 ± 8, 44 ± 8 and 36 ± 6 ml for 3 groups (p < 0.001). The effective radiation dose was 0.88 ± 0.04, 0.87 ± 0.06, and 0.85 ± 0.07 mSv for 3 groups. Contrast medium could be reduced to 0.5 ml/kg for high-pitch coronary CT angiography without compromising diagnostic image quality, which associated ~50 % reduction of total contrast volume compared with standard contrast protocol with test bolus technique.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23288418     DOI: 10.1007/s10554-012-0170-x

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  30 in total

Review 1.  IV contrast infusion for coronary artery CT angiography: literature review and results of a nationwide survey.

Authors:  Pamela T Johnson; Harpreet K Pannu; Elliot K Fishman
Journal:  AJR Am J Roentgenol       Date:  2009-05       Impact factor: 3.959

2.  64-Slice spiral computed tomography of the coronary arteries: dose reduction using an optimized imaging protocol including individual weight-adaptation of voltage and current-time product.

Authors:  Gunnar K Lund; Eckhard Wegian; Maythem Saeed; Jens Wassermeyer; Gerhard Adam; Alexander Stork
Journal:  Eur Radiol       Date:  2009-01-10       Impact factor: 5.315

3.  Feasibility of low-volume injections of contrast material with a body weight-adapted iodine-dose protocol in 320-detector row coronary CT angiography.

Authors:  Fuminari Tatsugami; Mitsuru Matsuki; Yuki Inada; Shuji Kanazawa; Go Nakai; Yoshihiro Takeda; Hideaki Morita; Haruhiko Takada; Kenji Ashida; Shushi Yoshikawa; Katsunori Fukumura; Yoshifumi Narumi
Journal:  Acad Radiol       Date:  2009-11-17       Impact factor: 3.173

4.  Coronary enhancement for prospective ECG-gated single R-R axial 320-MDCT angiography: comparison of 60- and 80-mL iopamidol 370 injection.

Authors:  Kanako K Kumamaru; Michael L Steigner; Shigeyoshi Soga; Jason Signorelli; Arash Bedayat; Kimberly Adams; Dimitris Mitsouras; Frank J Rybicki
Journal:  AJR Am J Roentgenol       Date:  2011-10       Impact factor: 3.959

5.  Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study.

Authors:  Wen Jie Yang; Ke Min Chen; Bo Liu; Li Fang Pang; Huan Zhang; Zi Lai Pan; Fu Hua Yan
Journal:  Int J Cardiovasc Imaging       Date:  2012-05-23       Impact factor: 2.357

6.  Contrast-induced nephropathy after a second contrast exposure.

Authors:  Hariprasad Trivedi; W Dennis Foley
Journal:  Ren Fail       Date:  2010       Impact factor: 2.606

7.  Body physique and heart rate variability determine the occurrence of stair-step artefacts in 64-slice CT coronary angiography with prospective ECG-triggering.

Authors:  Lars Husmann; Bernhard A Herzog; Nina Burkhard; Fuminari Tatsugami; Ines Valenta; Oliver Gaemperli; Christophe A Wyss; Ulf Landmesser; Philipp A Kaufmann
Journal:  Eur Radiol       Date:  2009-02-24       Impact factor: 5.315

8.  Feasibility of contrast material volume reduction in coronary artery imaging using 320-slice volume CT.

Authors:  Patrick A Hein; Juliane May; Patrik Rogalla; Craig Butler; Bernd Hamm; Alexander Lembcke
Journal:  Eur Radiol       Date:  2009-12-17       Impact factor: 5.315

9.  Incidence of and risk factors for contrast-induced nephropathy after cardiac catheterization in Japanese patients.

Authors:  Mitsuru Abe; Takeshi Kimura; Takeshi Morimoto; Yutaka Furukawa; Toru Kita
Journal:  Circ J       Date:  2009-06-17       Impact factor: 2.993

10.  Contrast-induced nephropathy and long-term adverse events: cause and effect?

Authors:  Richard J Solomon; Roxana Mehran; Madhu K Natarajan; Serge Doucet; Richard E Katholi; Cezar S Staniloae; Samin K Sharma; Marino Labinaz; Joseph L Gelormini; Brendan J Barrett
Journal:  Clin J Am Soc Nephrol       Date:  2009-06-25       Impact factor: 8.237

View more
  7 in total

1.  Personalized administration of contrast medium with high delivery rate in low tube voltage coronary computed tomography angiography.

Authors:  Sock Keow Tan; Kwan Hoong Ng; Chai Hong Yeong; Raja Rizal Azman Raja Aman; Fadhli Mohamed Sani; Yang Faridah Abdul Aziz; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2019-04

2.  Improving Patient to Patient CT Value Uniformity with an Individualized Contrast Medium Protocol Tailored to Body Weight and Contrast Medium Concentration in Coronary CT Angiography.

Authors:  Yan Xing; Gulina Azati; Cun-xue Pan; Jun Dang; Sailendra Jha; Wen-ya Liu
Journal:  PLoS One       Date:  2015-07-13       Impact factor: 3.240

3.  A Survey Exploring Personalised Medicine amongst Radiography Academics within the United Kingdom.

Authors:  Jerome Atutornu; Christopher M Hayre
Journal:  J Med Imaging Radiat Sci       Date:  2020-07-01

4.  Medical imaging in personalised medicine: a white paper of the research committee of the European Society of Radiology (ESR).

Authors: 
Journal:  Insights Imaging       Date:  2015-03-13

5.  Personalization of CM Injection Protocols in Coronary Computed Tomographic Angiography (People CT Trial).

Authors:  N G Eijsvoogel; B M F Hendriks; P Nelemans; C Mihl; J Willigers; B Martens; J E Wildberger; M Das
Journal:  Contrast Media Mol Imaging       Date:  2020-01-17       Impact factor: 3.161

6.  Contrast medium administration with a body surface area protocol in step-and-shoot coronary computed tomography angiography with dual-source scanners.

Authors:  Liang Jin; Yiyi Gao; Yingli Sun; Cheng Li; Pan Gao; Wei Zhao; Ming Li
Journal:  Sci Rep       Date:  2020-10-07       Impact factor: 4.379

7.  Coronary computed tomography angiography (CCTA): effect of bolus-tracking ROI positioning on image quality.

Authors:  Heiner Nebelung; Thomas Brauer; Danilo Seppelt; Ralf-Thorsten Hoffmann; Ivan Platzek
Journal:  Eur Radiol       Date:  2020-08-18       Impact factor: 5.315

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.