Literature DB >> 21120612

Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience.

Márcio Sommer Bittencourt1, Bernhard Schmidt, Martin Seltmann, Gerd Muschiol, Dieter Ropers, Werner Günther Daniel, Stephan Achenbach.   

Abstract

Improvements in image quality in cardiac computed tomography may be achieved through iterative image reconstruction techniques. We evaluated the ability of "Iterative Reconstruction in Image Space" (IRIS) reconstruction to reduce image noise and improve subjective image quality. 55 consecutive patients undergoing coronary CT angiography to rule out coronary artery stenosis were included. A dual source CT system and standard protocols were used. Images were reconstructed using standard filtered back projection and IRIS. Image noise, attenuation within the coronary arteries, contrast, signal to noise and contrast to noise parameters as well as subjective classification of image quality (using a scale with four categories) were evaluated and compared between the two image reconstruction protocols. Subjective image quality (2.8 ± 0.4 in filtered back projection and 2.8 ± 0.4 in iterative reconstruction) and the number of "evaluable" segments per patient 14.0 ± 1.2 in filtered back projection and 14.1 ± 1.1 in iterative reconstruction) were not significant different between the two methods. However iterative reconstruction had a lower image noise (22.6 ± 4.5 HU vs. 28.6 ± 5.1 HU) and higher signal to noise and image to noise ratios in the proximal coronary arteries. IRIS reduces image noise and contrast-to-noise ratio in coronary CT angiography, thus providing potential for reducing radiation exposure.

Entities:  

Mesh:

Year:  2010        PMID: 21120612     DOI: 10.1007/s10554-010-9756-3

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  16 in total

1.  Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography.

Authors:  Jonathon Leipsic; Troy M Labounty; Brett Heilbron; James K Min; G B John Mancini; Fay Y Lin; Carolyn Taylor; Allison Dunning; James P Earls
Journal:  AJR Am J Roentgenol       Date:  2010-09       Impact factor: 3.959

Review 2.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

3.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

Review 4.  An outlook on x-ray CT research and development.

Authors:  Ge Wang; Hengyong Yu; Bruno De Man
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

5.  High-pitch electrocardiogram-triggered computed tomography of the chest: initial results.

Authors:  Michael Lell; Fabian Hinkmann; Katharina Anders; Paul Deak; Willi A Kalender; Michael Uder; Stephan Achenbach
Journal:  Invest Radiol       Date:  2009-11       Impact factor: 6.016

6.  Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition.

Authors:  Stephan Achenbach; Mohamed Marwan; Dieter Ropers; Tiziano Schepis; Tobias Pflederer; Katharina Anders; Axel Kuettner; Werner G Daniel; Michael Uder; Michael M Lell
Journal:  Eur Heart J       Date:  2009-11-05       Impact factor: 29.983

7.  A new iterative reconstruction technique for attenuation correction in high-resolution positron emission tomography.

Authors:  K Knesaurek; J Machac; S Vallabhajosula; M S Buchsbaum
Journal:  Eur J Nucl Med       Date:  1996-06

8.  Improved resolution for PET volume imaging through three-dimensional iterative reconstruction.

Authors:  J S Liow; S C Strother; K Rehm; D A Rottenberg
Journal:  J Nucl Med       Date:  1997-10       Impact factor: 10.057

Review 9.  Strategies for CT radiation dose optimization.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Leena M Hamberg; Michael A Blake; Jo-Anne Shepard; Sanjay Saini
Journal:  Radiology       Date:  2004-01-22       Impact factor: 11.105

10.  Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: comparison of image quality and patient radiation dose.

Authors:  William P Shuman; Kelley R Branch; Janet M May; Lee M Mitsumori; David W Lockhart; Theodore J Dubinsky; Bill H Warren; James H Caldwell
Journal:  Radiology       Date:  2008-06-13       Impact factor: 11.105

View more
  55 in total

Review 1.  CT angiography in the diagnosis of cardiovascular disease: a transformation in cardiovascular CT practice.

Authors:  Zhonghua Sun; Mansour Al Moudi; Yan Cao
Journal:  Quant Imaging Med Surg       Date:  2014-10

2.  Iterative reconstruction in head CT: image quality of routine and low-dose protocols in comparison with standard filtered back-projection.

Authors:  A Korn; M Fenchel; B Bender; S Danz; T K Hauser; D Ketelsen; T Flohr; C D Claussen; M Heuschmid; U Ernemann; H Brodoefel
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-27       Impact factor: 3.825

3.  Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose.

Authors:  Eun-Ah Park; Whal Lee; Kwang Woo Kim; Kwang Gi Kim; Allmendinger Thomas; Jin Wook Chung; Jae Hyung Park
Journal:  Int J Cardiovasc Imaging       Date:  2011-12-21       Impact factor: 2.357

4.  The effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography.

Authors:  F Tatsugami; M Matsuki; G Nakai; Y Inada; S Kanazawa; Y Takeda; H Morita; H Takada; S Yoshikawa; K Fukumura; Y Narumi
Journal:  Br J Radiol       Date:  2012-01-17       Impact factor: 3.039

5.  Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults.

Authors:  Gaurav S Desai; Raul N Uppot; Elaine W Yu; Avinash R Kambadakone; Dushyant V Sahani
Journal:  Eur Radiol       Date:  2012-04-19       Impact factor: 5.315

6.  Effect of hybrid iterative reconstruction technique on quantitative and qualitative image analysis at 256-slice prospective gating cardiac CT.

Authors:  Daisuke Utsunomiya; Wm Guy Weigold; Gaby Weissman; Allen J Taylor
Journal:  Eur Radiol       Date:  2011-12-27       Impact factor: 5.315

7.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

8.  Impact of iterative reconstruction on CNR and SNR in dynamic myocardial perfusion imaging in an animal model.

Authors:  B M Gramer; D Muenzel; V Leber; A-K von Thaden; H Feussner; A Schneider; M Vembar; N Soni; E J Rummeny; A M Huber
Journal:  Eur Radiol       Date:  2012-07-03       Impact factor: 5.315

9.  Effect of bismuth breast shielding on radiation dose and image quality in coronary CT angiography.

Authors:  Andrew J Einstein; Carl D Elliston; Daniel W Groves; Bin Cheng; Steven D Wolff; Gregory D N Pearson; M Robert Peters; Lynne L Johnson; Sabahat Bokhari; Gary W Johnson; Ketan Bhatia; Theodore Pozniakoff; David J Brenner
Journal:  J Nucl Cardiol       Date:  2011-11-09       Impact factor: 5.952

10.  Assessment of dose exposure and image quality in coronary angiography performed by 640-slice CT: a comparison between adaptive iterative and filtered back-projection algorithm by propensity analysis.

Authors:  Ernesto Di Cesare; Antonio Gennarelli; Alessandra Di Sibio; Valentina Felli; Alessandra Splendiani; Giovanni Luca Gravina; Antonio Barile; Carlo Masciocchi
Journal:  Radiol Med       Date:  2014-02-20       Impact factor: 3.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.