Literature DB >> 22830765

Dose optimization with first-order total-variation minimization for dense angularly sampled and sparse intensity modulated radiation therapy (DASSIM-RT).

Hojin Kim1, Ruijiang Li, Rena Lee, Thomas Goldstein, Stephen Boyd, Emmanuel Candes, Lei Xing.   

Abstract

PURPOSE: A new treatment scheme coined as dense angularly sampled and sparse intensity modulated radiation therapy (DASSIM-RT) has recently been proposed to bridge the gap between IMRT and VMAT. By increasing the angular sampling of radiation beams while eliminating dispensable segments of the incident fields, DASSIM-RT is capable of providing improved conformity in dose distributions while maintaining high delivery efficiency. The fact that DASSIM-RT utilizes a large number of incident beams represents a major computational challenge for the clinical applications of this powerful treatment scheme. The purpose of this work is to provide a practical solution to the DASSIM-RT inverse planning problem.
METHODS: The inverse planning problem is formulated as a fluence-map optimization problem with total-variation (TV) minimization. A newly released L1-solver, template for first-order conic solver (TFOCS), was adopted in this work. TFOCS achieves faster convergence with less memory usage as compared with conventional quadratic programming (QP) for the TV form through the effective use of conic forms, dual-variable updates, and optimal first-order approaches. As such, it is tailored to specifically address the computational challenges of large-scale optimization in DASSIM-RT inverse planning. Two clinical cases (a prostate and a head and neck case) are used to evaluate the effectiveness and efficiency of the proposed planning technique. DASSIM-RT plans with 15 and 30 beams are compared with conventional IMRT plans with 7 beams in terms of plan quality and delivery efficiency, which are quantified by conformation number (CN), the total number of segments and modulation index, respectively. For optimization efficiency, the QP-based approach was compared with the proposed algorithm for the DASSIM-RT plans with 15 beams for both cases.
RESULTS: Plan quality improves with an increasing number of incident beams, while the total number of segments is maintained to be about the same in both cases. For the prostate patient, the conformation number to the target was 0.7509, 0.7565, and 0.7611 with 80 segments for IMRT with 7 beams, and DASSIM-RT with 15 and 30 beams, respectively. For the head and neck (HN) patient with a complicated target shape, conformation numbers of the three treatment plans were 0.7554, 0.7758, and 0.7819 with 75 segments for all beam configurations. With respect to the dose sparing to the critical structures, the organs such as the femoral heads in the prostate case and the brainstem and spinal cord in the HN case were better protected with DASSIM-RT. For both cases, the delivery efficiency has been greatly improved as the beam angular sampling increases with the similar or better conformal dose distribution. Compared with conventional quadratic programming approaches, first-order TFOCS-based optimization achieves far faster convergence and smaller memory requirements in DASSIM-RT.
CONCLUSIONS: The new optimization algorithm TFOCS provides a practical and timely solution to the DASSIM-RT or other inverse planning problem requiring large memory space. The new treatment scheme is shown to outperform conventional IMRT in terms of dose conformity to both the targetand the critical structures, while maintaining high delivery efficiency.

Entities:  

Mesh:

Year:  2012        PMID: 22830765      PMCID: PMC4108706          DOI: 10.1118/1.4729717

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  34 in total

1.  Leaf sequencing with secondary beam blocking under leaf positioning constraints for continuously modulated radiotherapy beams.

Authors:  H G Kuterdem; P S Cho
Journal:  Med Phys       Date:  2001-06       Impact factor: 4.071

2.  Bridging the gap between IMRT and VMAT: dense angularly sampled and sparse intensity modulated radiation therapy.

Authors:  Ruijiang Li; Lei Xing
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

3.  GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation.

Authors:  Xun Jia; Yifei Lou; Ruijiang Li; William Y Song; Steve B Jiang
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

4.  Compressed sensing based cone-beam computed tomography reconstruction with a first-order method.

Authors:  Kihwan Choi; Jing Wang; Lei Zhu; Tae-Suk Suh; Stephen Boyd; Lei Xing
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

5.  Single-Arc IMRT?

Authors:  Thomas Bortfeld; Steve Webb
Journal:  Phys Med Biol       Date:  2008-12-10       Impact factor: 3.609

6.  Search for IMRT inverse plans with piecewise constant fluence maps using compressed sensing techniques.

Authors:  Lei Zhu; Lei Xing
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

7.  Inverse planning for IMRT with nonuniform beam profiles using total-variation regularization (TVR).

Authors:  Taeho Kim; Lei Zhu; Tae-Suk Suh; Sarah Geneser; Bowen Meng; Lei Xing
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

8.  [Dosimetric evaluation of conformal radiotherapy: conformity factor].

Authors:  R Oozeer; B Chauvet; R Garcia; C Berger; C Felix-Faure; F Reboul
Journal:  Cancer Radiother       Date:  2000 May-Jun       Impact factor: 1.018

9.  Role of beam orientation optimization in intensity-modulated radiation therapy.

Authors:  A Pugachev; J G Li; A L Boyer; S L Hancock; Q T Le; S S Donaldson; L Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-06-01       Impact factor: 7.038

10.  Volumetric modulated arc therapy: planning and evaluation for prostate cancer cases.

Authors:  Pengpeng Zhang; Laura Happersett; Margie Hunt; Andrew Jackson; Michael Zelefsky; Gig Mageras
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-06-18       Impact factor: 7.038

View more
  3 in total

1.  Nonisocentric treatment strategy for breast radiation therapy: a proof of concept study.

Authors:  Ruijiang Li; Lei Xing; Kathleen C Horst; Karl Bush
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-03-15       Impact factor: 7.038

2.  Fraction-variant beam orientation optimization for non-coplanar IMRT.

Authors:  Daniel O'Connor; Victoria Yu; Dan Nguyen; Dan Ruan; Ke Sheng
Journal:  Phys Med Biol       Date:  2018-02-15       Impact factor: 3.609

3.  A comprehensive formulation for volumetric modulated arc therapy planning.

Authors:  Dan Nguyen; Qihui Lyu; Dan Ruan; Daniel O'Connor; Daniel A Low; Ke Sheng
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.