Literature DB >> 11695772

Smoothing intensity-modulated beam profiles to improve the efficiency of delivery.

S V Spirou1, N Fournier-Bidoz, J Yang, C S Chui, C C Ling.   

Abstract

Intensity-modulated beam profiles are generated by an inverse planning or optimization algorithm, a process that, being computationally complex and intensive, is inherently susceptible to noise and numerical artifacts. These artifacts make delivery of the beams more difficult, oftentimes for little, if any, observable improvement in the dose distributions. In this work we examine two approaches for smoothing the beam profiles. The first approach is to smooth the beam profiles subsequent to each iteration in the optimization process (method A). The second approach is to include a term within the objective function that specifies the smoothness of the profiles as an optimization criterion (method B). The two methods were applied to a phantom study as well as three clinical sites: paraspinal, nasopharynx, and prostate. For the paraspinal and nasopharynx cases, which have critical organs with low tolerance doses in close proximity, method B produced sharper dose gradients, better target dose homogeneity, and more critical organ sparing. In the less demanding prostate case, the two methods give similar results. In addition, method B is more efficient during optimization, requiring fewer iterations, but less efficient during DMLC delivery, requiring a longer beam-on time.

Entities:  

Mesh:

Year:  2001        PMID: 11695772     DOI: 10.1118/1.1406522

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Improving IMRT delivery efficiency with reweighted L1-minimization for inverse planning.

Authors:  Hojin Kim; Stephen Becker; Rena Lee; Soonhyouk Lee; Sukyoung Shin; Emmanuel Candès; Lei Xing; Ruijiang Li
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

2.  Search for IMRT inverse plans with piecewise constant fluence maps using compressed sensing techniques.

Authors:  Lei Zhu; Lei Xing
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

3.  Adaptive diffusion smoothing: a diffusion-based method to reduce IMRT field complexity.

Authors:  Martha M Matuszak; Edward W Larsen; Kyung-Wook Jee; Daniel L McShan; Benedick A Fraass
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

4.  Inverse planning for IMRT with nonuniform beam profiles using total-variation regularization (TVR).

Authors:  Taeho Kim; Lei Zhu; Tae-Suk Suh; Sarah Geneser; Bowen Meng; Lei Xing
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

Review 5.  Influence of segment width on plan quality for volumetric modulated arc based stereotactic body radiotherapy.

Authors:  Karthikeyan Nithiyanantham; Ganesh Kadirampatti Mani; Vikraman Subramani; Karrthick Karukkupalayam Palaniappan; Mohanraj Uthiran; Sennniandavar Vellengiri; Sambasivaselli Raju; Sanjay S Supe; Tejinder Kataria
Journal:  Rep Pract Oncol Radiother       Date:  2014-04-16

6.  Robust optimization in IMPT using quadratic objective functions to account for the minimum MU constraint.

Authors:  Jie Shan; Yu An; Martin Bues; Steven E Schild; Wei Liu
Journal:  Med Phys       Date:  2017-12-05       Impact factor: 4.071

7.  Use of plan quality degradation to evaluate tradeoffs in delivery efficiency and clinical plan metrics arising from IMRT optimizer and sequencer compromises.

Authors:  Joel R Wilkie; Martha M Matuszak; Mary Feng; Jean M Moran; Benedick A Fraass
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

8.  Effect of fluence smoothing on the quality of intensity-modulated radiation treatment plans.

Authors:  Puzhakkal Niyas; Kallikuzhiyil Kochunny Abdullah; Manthala Padannayil Noufal; Thekkedath Sankaran Nair
Journal:  Radiol Phys Technol       Date:  2016-03-07

9.  A dosimetric analysis of 6 MV versus 15 MV photon energy plans for intensity modulated radiation therapy (IMRT) of carcinoma of cervix.

Authors:  Atul Tyagi; Sanjay S Supe; Man P Singh
Journal:  Rep Pract Oncol Radiother       Date:  2010-09-22

10.  A hybrid algorithm for instant optimization of beam weights in anatomy-based intensity modulated radiotherapy: A performance evaluation study.

Authors:  Ranganathan Vaitheeswaran; Narayanan V K Sathiya; Janhavi R Bhangle; Amit Nirhali; Namita Kumar; Sumit Basu; Vikram Maiya
Journal:  J Med Phys       Date:  2011-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.