A comparison of two implant systems in restoration of hip geometry in arthroplasty.

Michael J Archibeck1, Tamara Cummins, Joshua Carothers, Daniel W Junick, Richard E White.   

Abstract

BACKGROUND: Restoration of hip offset and leg length during THA is often limited by available implant geometries. The recent introduction of femoral components with a modular junction at the base of the neck (two modular junction components) has expanded the options to restore femoral offset and leg length. QUESTIONS/PURPOSES: We asked (1) whether a femoral component with two modular junctions would predict by templating more frequent restoration of preoperative offset and leg length abnormalities than one with single modular junctions; and (2) how our use of these options compared with national sales data. PATIENTS AND METHODS: We retrospectively reviewed the preoperative templating data in 100 primary THAs using single modular junction implants with only a neutral version stem and 100 THAs using two modular junction implants. We compared the frequency with which the desired leg length and offset were completely restored by preoperative templating in the two groups.
RESULTS: Offset and leg lengths were restored to within 1 mm in 85% of cases with two modular junction implants and 60% of cases with single modular junction implants. An anteverted or a retroverted neck was used in 25% of cases with the two modular junction stems. The national sales data revealed femoral neck components with version were used in 28% of cases.
CONCLUSIONS: The use of a femoral component with two modular junctions resulted in more frequent ability to restore femoral offset and leg length than a single modular junction. The advantage of clinical flexibility should be tempered by the potential concerns of prosthetic mechanical failure (which has been reported in another implant system with two modular junctions), increased third-body wear and corrosive debris, and increased prosthetic cost. LEVEL OF EVIDENCE: Level II, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2011        PMID: 21082363      PMCID: PMC3018197          DOI: 10.1007/s11999-010-1678-9

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  12 in total

1.  Soft tissue balancing: the hip.

Authors:  Robert B Bourne; Cecil H Rorabeck
Journal:  J Arthroplasty       Date:  2002-06       Impact factor: 4.757

Review 2.  Leg length discrepancy after total hip arthroplasty.

Authors:  William J Maloney; James A Keeney
Journal:  J Arthroplasty       Date:  2004-06       Impact factor: 4.757

3.  Impingement in total hip arthroplasty a study of retrieved acetabular components.

Authors:  Won Yong Shon; Todd Baldini; Margaret G Peterson; Timothy M Wright; Eduardo A Salvati
Journal:  J Arthroplasty       Date:  2005-06       Impact factor: 4.757

Review 4.  Impingement with total hip replacement.

Authors:  Aamer Malik; Aditya Maheshwari; Lawrence D Dorr
Journal:  J Bone Joint Surg Am       Date:  2007-08       Impact factor: 5.284

5.  [Preoperative planning and reconstruction in primary total hip arthroplasty with and without modular necks].

Authors:  H Heep; A Wegner; J Xu; M Kauther; F A Loeer
Journal:  Z Orthop Unfall       Date:  2010-03       Impact factor: 0.923

6.  Fretting wear in a modular neck hip prosthesis.

Authors:  M Viceconti; M Baleani; S Squarzoni; A Toni
Journal:  J Biomed Mater Res       Date:  1997-05

7.  The importance of leg length discrepancy after total hip arthroplasty.

Authors:  A Konyves; G C Bannister
Journal:  J Bone Joint Surg Br       Date:  2005-02

8.  The Frank Stinchfield Award: Morphologic features of the acetabulum and femur: anteversion angle and implant positioning.

Authors:  M Maruyama; J R Feinberg; W N Capello; J A D'Antonio
Journal:  Clin Orthop Relat Res       Date:  2001-12       Impact factor: 4.176

9.  Stability and leg length equality in total hip arthroplasty.

Authors:  Matthew S Austin; William J Hozack; Peter F Sharkey; Richard H Rothman
Journal:  J Arthroplasty       Date:  2003-04       Impact factor: 4.757

10.  Lateral trochanteric pain following primary total hip arthroplasty.

Authors:  Richard Iorio; William L Healy; Paul D Warren; David Appleby
Journal:  J Arthroplasty       Date:  2006-02       Impact factor: 4.757

View more
  10 in total

1.  What Factors Are Associated With Neck Fracture in One Commonly Used Bimodular THA Design? A Multicenter, Nationwide Study in Slovenia.

Authors:  Simon Kovač; Blaž Mavčič; Marko Kotnik; Vesna Levašič; Mateja Sirše; Samo Karel Fokter
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

2.  CORR Insights®: Exchangeable Femoral Neck (Dual-Modular) THA Prostheses Have Poorer Survivorship than Other Designs: A Nationwide Cohort of 324,108 Patients.

Authors:  H John Cooper
Journal:  Clin Orthop Relat Res       Date:  2017-02-24       Impact factor: 4.176

3.  Anatomy of the proximal femur at the time of total hip arthroplasty is a matter of morphotype and etiology but not gender.

Authors:  Matthieu Ollivier; Sebastien Parratte; Thomas Le Corroller; Thomas Lecorroller; Andrea Reggiori; Pierre Champsaur; Jean-Noël Argenson
Journal:  Surg Radiol Anat       Date:  2014-09-06       Impact factor: 1.246

4.  Result of Modular Necks in Primary Total Hip Arthroplasty with a Average Follow-up of Four Years.

Authors:  Jemin Yi; Kye Young Han; Young Jun Nam; Keun Woo Kim
Journal:  Hip Pelvis       Date:  2016-09-30

5.  Diagnosis and Management of Adverse Reactions to Metal Debris.

Authors:  Richard A Wawrose; Kenneth L Urish
Journal:  Oper Tech Orthop       Date:  2019-10-01

6.  Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck.

Authors:  H John Cooper; Robert M Urban; Richard L Wixson; R Michael Meneghini; Joshua J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2013-05-15       Impact factor: 5.284

7.  Trunnionosis: A pain in the neck.

Authors:  Philip S Pastides; Matthew Dodd; Khaled M Sarraf; Charles A Willis-Owen
Journal:  World J Orthop       Date:  2013-10-18

Review 8.  Titanium alloy femoral neck fracture--clinical and metallurgical analysis in 6 cases.

Authors:  Samo K Fokter; Rebeka Rudolf; Andrej Moličnik
Journal:  Acta Orthop       Date:  2015-05-04       Impact factor: 3.717

9.  Total hip arthroplasty with modular stem for Crowe I and II developmental dysplasia of the hip.

Authors:  Xiangpeng Kong; Yunming Sun; Minzhi Yang; Yonggang Zhou; Jiying Chen; Wei Chai; Yan Wang
Journal:  J Orthop Surg Res       Date:  2019-11-13       Impact factor: 2.359

10.  Unexpected varus deformity and concomitant metal ion release and MRI findings of modular-neck hip stems: descriptive RSA study in 75 hips with 8 years' follow-up.

Authors:  Sverrir Kiernan; Bart Kaptein; Carl Flivik; Martin Sundberg; Gunnar Flivik
Journal:  Acta Orthop       Date:  2020-12-10       Impact factor: 3.717

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.