Fretting wear in a modular neck hip prosthesis.

M Viceconti1, M Baleani, S Squarzoni, A Toni.   

Abstract

In vitro cyclic load fretting tests were conducted on a prototype of a cementless, modular neck, hip prosthesis. The study had three major objectives: to determine the amount of fretted material in the tapered-neck joint under various load cycle amplitudes, to determine the fretting damage evolution, and to determine the effect of different-sized stem bodies on the production of debris. All the tests produced some fretting microdamage on the tapered surface although the extent was quite different among test groups. The amount of abraded material increased almost linearly with the applied load magnitude but not with the number of load cycles. The amount of weight loss was higher in the large stem bodies than in the small ones. Weight loss ranged from 0.28 +/- 0.10 mg for small stem bodies loaded 5.5 million times up to 2300N to 2.54 +/- 0.53 mg for large stem bodies located 20 million times up to 3300N. Considering the large-size stem results, and assuming one million load cycles between 300N and 3300N to be the average yearly load history, the modular neck tapered joint would produce 0.6 mg/year of metal debris. The clinical impact of this observation is unknown; however, some of the literature on the presence of metal in patient tissues and fluids supports the hypothesis that a normal and stable prosthesis is likely to produce less than 10 mg/year of metal debris. Thus, a further production of 0.6 mg/year due to the modular neck should not have any significant effect.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9135170     DOI: 10.1002/(sici)1097-4636(199705)35:2<207::aid-jbm9>3.0.co;2-r

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  22 in total

1.  Assessment of wear on the cones of modular stainless steel Exeter hip stems.

Authors:  R P S Chaplin; A J C Lee; R M Hooper
Journal:  J Mater Sci Mater Med       Date:  2004-09       Impact factor: 3.896

2.  Fracture of a modular femoral neck after total hip arthroplasty: a case report.

Authors:  Geoffrey Wright; Scott Sporer; Robert Urban; Joshua Jacobs
Journal:  J Bone Joint Surg Am       Date:  2010-06       Impact factor: 5.284

3.  A comparison of two implant systems in restoration of hip geometry in arthroplasty.

Authors:  Michael J Archibeck; Tamara Cummins; Joshua Carothers; Daniel W Junick; Richard E White
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

4.  New technology: safety, efficacy, and learning curves.

Authors:  Paul J Duwelius; Javad Parvizi; Laura Matsen Ko
Journal:  Clin Orthop Relat Res       Date:  2013-12-07       Impact factor: 4.176

5.  Is increased modularity associated with increased fretting and corrosion damage in metal-on-metal total hip arthroplasty devices?: a retrieval study.

Authors:  Genymphas B Higgs; Josa A Hanzlik; Daniel W MacDonald; Jeremy L Gilbert; Clare M Rimnac; Steven M Kurtz
Journal:  J Arthroplasty       Date:  2013-08-01       Impact factor: 4.757

6.  Stem-Sleeve Junction Failure of a Modular Femoral Hip System: a Retrieval Analysis.

Authors:  Feras Waly; Fahad H Abduljabbar; Trevor Gascoyne; Thomas R Turgeon; Olga Huk
Journal:  HSS J       Date:  2015-07-09

7.  A stature-specific concept for uncemented, primary total hip arthroplasty.

Authors:  Georg W Omlor; Hannah Ullrich; Knut Krahmer; Alexander Jung; Günther Aldinger; Peter Aldinger
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

8.  Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck.

Authors:  H John Cooper; Robert M Urban; Richard L Wixson; R Michael Meneghini; Joshua J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2013-05-15       Impact factor: 5.284

9.  High Risk of Failure With Bimodular Femoral Components in THA.

Authors:  Aidin Eslam Pour; Robert Borden; Takayuki Murayama; Mary Groll-Brown; J David Blaha
Journal:  Clin Orthop Relat Res       Date:  2015-09-01       Impact factor: 4.176

10.  Modular titanium alloy neck adapter failures in hip replacement--failure mode analysis and influence of implant material.

Authors:  Thomas M Grupp; Thomas Weik; Wilhelm Bloemer; Hanns-Peter Knaebel
Journal:  BMC Musculoskelet Disord       Date:  2010-01-04       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.