Literature DB >> 15736733

The importance of leg length discrepancy after total hip arthroplasty.

A Konyves1, G C Bannister.   

Abstract

We assessed leg length discrepancy and hip function in 90 patients undergoing primary total hip arthroplasty before surgery and at three and 12 months after. Function was measured using the Oxford hip score (OHS). After surgery the mean OHS improved by 26 points after three months and by 30 points after 12. After operation 56 (62%) limbs were long by a mean of 9 mm and this was perceived by 24 (43%) patients after three months and by 18 (33%) after 12. The mean OHS in patients who perceived true lengthening was 27% worse than the rest of the population after three months and 18% worse after 12. In 55 (98%) patients, lengthening occurred in the femoral component. Appropriate placement of the femoral component could significantly reduce a patient's perception of discrepancy of length.

Entities:  

Mesh:

Year:  2005        PMID: 15736733     DOI: 10.1302/0301-620x.87b2.14878

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  65 in total

1.  Influence of self-reported limb length discrepancy on function and satisfaction 6 years after total hip replacement.

Authors:  Maura D Iversen; Nidhi Chudasama; Elena Losina; Jeffrey N Katz
Journal:  J Geriatr Phys Ther       Date:  2011 Jul-Sep       Impact factor: 3.381

2.  [Principles and new concepts in computer-navigated total hip arthroplasty].

Authors:  T Renkawitz; M Wörner; E Sendtner; M Weber; P Lechler; J Grifka
Journal:  Orthopade       Date:  2011-12       Impact factor: 1.087

3.  A comparison of two implant systems in restoration of hip geometry in arthroplasty.

Authors:  Michael J Archibeck; Tamara Cummins; Joshua Carothers; Daniel W Junick; Richard E White
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

4.  MyHip: supporting planning and surgical guidance for a better total hip arthroplasty : A pilot study.

Authors:  Jérôme Schmid; Christophe Chênes; Sylvain Chagué; Pierre Hoffmeyer; Panayiotis Christofilopoulos; Massimiliano Bernardoni; Caecilia Charbonnier
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-01       Impact factor: 2.924

5.  Preoperative radiographic assessment of limb-length discrepancy in total hip arthroplasty.

Authors:  Geert Meermans; Ahmad Malik; Johan Witt; Fares Haddad
Journal:  Clin Orthop Relat Res       Date:  2010-09-29       Impact factor: 4.176

6.  Leg length discrepancy in total hip arthroplasty: comparison of two methods of measurement.

Authors:  Arkan S Sayed-Noor; Anders Hugo; Göran O Sjödén; Per Wretenberg
Journal:  Int Orthop       Date:  2008-08-02       Impact factor: 3.075

7.  Leg length discrepancy after total hip arthroplasty: a review of literature.

Authors:  Aravind S Desai; Asterios Dramis; Tim N Board
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

8.  Measurement of leg length discrepancy after total hip arthroplasty. The reliability of a plain radiographic method compared to CT-scanogram.

Authors:  Martin Kjellberg; Bariq Al-Amiry; Erling Englund; Göran O Sjödén; Arkan S Sayed-Noor
Journal:  Skeletal Radiol       Date:  2011-04-14       Impact factor: 2.199

9.  Does computer-assisted surgery benefit leg length restoration in total hip replacement? Navigation versus conventional freehand.

Authors:  Alfonso Manzotti; Pietro Cerveri; Elena De Momi; Chris Pullen; Norberto Confalonieri
Journal:  Int Orthop       Date:  2009-11-11       Impact factor: 3.075

10.  Fluoroscopy and imageless navigation enable an equivalent reconstruction of leg length and global and femoral offset in THA.

Authors:  Markus Weber; Michael Woerner; Robert Springorum; Ernst Sendtner; Alexander Hapfelmeier; Joachim Grifka; Tobias Renkawitz
Journal:  Clin Orthop Relat Res       Date:  2014-06-26       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.