Literature DB >> 12730937

Stability and leg length equality in total hip arthroplasty.

Matthew S Austin1, William J Hozack, Peter F Sharkey, Richard H Rothman.   

Abstract

Limp is one of the most frustrating persistent symptoms after hip arthroplasty for both the patient and surgeon. There are a multitude of causes of limp; however, leg-length inequality is the leading culprit. Leg-length inequality can lead to anger, litigation, morbidity, and ultimately revision surgery. However, geometrically equal leg lengths may not be an attainable goal in all patients. The stability of the total hip arthroplasty is intimately related to leg length, and equality may need to be sacrificed for stability. Therefore, both the patient and the surgeon should have realistic expectations and an awareness of this problem. Copyright 2003 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2003        PMID: 12730937     DOI: 10.1054/arth.2003.50073

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  17 in total

1.  Influence of self-reported limb length discrepancy on function and satisfaction 6 years after total hip replacement.

Authors:  Maura D Iversen; Nidhi Chudasama; Elena Losina; Jeffrey N Katz
Journal:  J Geriatr Phys Ther       Date:  2011 Jul-Sep       Impact factor: 3.381

2.  A comparison of two implant systems in restoration of hip geometry in arthroplasty.

Authors:  Michael J Archibeck; Tamara Cummins; Joshua Carothers; Daniel W Junick; Richard E White
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

3.  Preoperative radiographic assessment of limb-length discrepancy in total hip arthroplasty.

Authors:  Geert Meermans; Ahmad Malik; Johan Witt; Fares Haddad
Journal:  Clin Orthop Relat Res       Date:  2010-09-29       Impact factor: 4.176

4.  Leg length discrepancy after total hip arthroplasty: a review of literature.

Authors:  Aravind S Desai; Asterios Dramis; Tim N Board
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

5.  Preoperative digital planning versus postoperative outcomes in total hip arthroplasty using a calcar-guided short stem: frequent valgization can be avoided.

Authors:  Karl Philipp Kutzner; Joachim Pfeil; Mark Predrag Kovacevic
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-04-08

6.  Effect of improved navigation performance on the accuracy of implant placement in total hip arthroplasty with a CT-based navigation system.

Authors:  Ichiro Nakahara; Takayuki Kyo; Yasuo Kuroda; Hidenobu Miki
Journal:  J Artif Organs       Date:  2018-04-02       Impact factor: 1.731

7.  To what extent does leg length discrepancy impair motor activity in patients after total hip arthroplasty?

Authors:  Maria Grazia Benedetti; Fabio Catani; Emanuela Benedetti; Lisa Berti; Annalisa Di Gioia; Sandro Giannini
Journal:  Int Orthop       Date:  2009-09-18       Impact factor: 3.075

8.  Total hip arthroplasty in patients with haemophilia - What are the risks of bleeding in the immediate peri-operative period?

Authors:  Grainne Colgan; Joseph F Baker; N Donlon; N Hogan; T McCarthy
Journal:  J Orthop       Date:  2016-07-27

9.  Prevalence and functional impact of patient-perceived leg length discrepancy after hip replacement.

Authors:  V Wylde; S L Whitehouse; A H Taylor; G T Pattison; G C Bannister; A W Blom
Journal:  Int Orthop       Date:  2008-04-25       Impact factor: 3.075

10.  The clinical value of combined use of MR imaging and multi-slice spiral CT in limb salvage surgery for orthopaedic oncology patients: initial experience in nine patients.

Authors:  Jie Xu; Jun Shen; Yue Ding; Hui-Yong Shen; Zhan-Peng Zeng; Ruo-Fan Ma; Chun-Hai Li; Bertram Barden
Journal:  Radiol Oncol       Date:  2012-04-19       Impact factor: 2.991

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.