Impingement in total hip arthroplasty a study of retrieved acetabular components.

Won Yong Shon1, Todd Baldini, Margaret G Peterson, Timothy M Wright, Eduardo A Salvati.   

Abstract

Impingement can damage the acetabular liner, create polyethylene wear, and cause dislocation. We determined the prevalence of impingement, its relation with dislocation, and the influence of patient, surgical, and design factors in 162 components randomly selected from a larger group retrieved between 1990 and 1999. Impingement arc, severity, and wear damage were measured; patient data were obtained from medical records, and component position was determined from radiographs. More than half (56%) showed impingement, including 94% of those removed for dislocation. The occurrence of impingement was significantly increased if the revision diagnosis was dislocation, if the component had a large outer diameter or an elevated rim, and if the femoral component had an extended flanged neck. Implant design, in particular head/neck ratio, can help reduce the prevalence of impingement.

Entities:  

Mesh:

Year:  2005        PMID: 16124957     DOI: 10.1016/j.arth.2004.09.058

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  54 in total

1.  Constrained cups appear incapable of meeting the demands of revision THA.

Authors:  Philip C Noble; Salim K Durrani; Molly M Usrey; Kenneth B Mathis; Nikolaos V Bardakos
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  [Principles and new concepts in computer-navigated total hip arthroplasty].

Authors:  T Renkawitz; M Wörner; E Sendtner; M Weber; P Lechler; J Grifka
Journal:  Orthopade       Date:  2011-12       Impact factor: 1.087

3.  Hard-on-hard total hip impingement causes extreme contact stress concentrations.

Authors:  Jacob M Elkins; Megan K O'Brien; Nicholas J Stroud; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

4.  A comparison of two implant systems in restoration of hip geometry in arthroplasty.

Authors:  Michael J Archibeck; Tamara Cummins; Joshua Carothers; Daniel W Junick; Richard E White
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

Review 5.  Edge loading has a paradoxical effect on wear in metal-on-polyethylene total hip arthroplasties.

Authors:  William H Harris
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

6.  Comparison of robotic-assisted and conventional acetabular cup placement in THA: a matched-pair controlled study.

Authors:  Benjamin G Domb; Youssef F El Bitar; Adam Y Sadik; Christine E Stake; Itamar B Botser
Journal:  Clin Orthop Relat Res       Date:  2013-08-29       Impact factor: 4.176

7.  Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?

Authors:  Adrian Bauze; Somen Agrawal; Alana Cuthbert; Richard de Steiger
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

8.  Effects of implant design parameters on fluid convection, potentiating third-body debris ingress into the bearing surface during THA impingement/subluxation.

Authors:  Hannah J Lundberg; Douglas R Pedersen; Thomas E Baer; Marian Muste; John J Callaghan; Thomas D Brown
Journal:  J Biomech       Date:  2007-04-02       Impact factor: 2.712

9.  Validation of a simple radiographic method to determine variations in pelvic and acetabular cup sagittal plane alignment after total hip arthroplasty.

Authors:  Won Yong Shon; Siddhartha Gupta; Sandeep Biswal; Chang Yong Hur; Nirmal Jajodia; Suk Joo Hong; Jae Sung Myung
Journal:  Skeletal Radiol       Date:  2008-08-07       Impact factor: 2.199

10.  Does CT-based navigation improve the long-term survival in ceramic-on-ceramic THA?

Authors:  Nobuhiko Sugano; Masaki Takao; Takashi Sakai; Takashi Nishii; Hidenobu Miki
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.