PET Performance Evaluation of an MR-Compatible PET Insert.

Yibao Wu1, Ciprian Catana, Richard Farrell, Purushottam A Dokhale, Kanai S Shah, Jinyi Qi, Simon R Cherry.   

Abstract

A magnetic resonance (MR) compatible positron emission tomography (PET) insert has been developed in our laboratory for simultaneous small animal PET/MR imaging. This system is based on lutetium oxyorthosilicate (LSO) scintillator arrays with position-sensitive avalanche photodiode (PSAPD) photodetectors. The PET performance of this insert has been measured. The average reconstructed image spatial resolution was 1.51 mm. The sensitivity at the center of the field of view (CFOV) was 0.35%, which is comparable to the simulation predictions of 0.40%. The average photopeak energy resolution was 25%. The scatter fraction inside the MRI scanner with a line source was 12% (with a mouse-sized phantom and standard 35 mm Bruker 1H RF coil), 7% (with RF coil only) and 5% (without phantom or RF coil) for an energy window of 350-650 keV. The front-end electronics had a dead time of 390 ns, and a trigger extension dead time of 7.32 μs that degraded counting rate performance for injected doses above ~0.75 mCi (28 MBq). The peak noise-equivalent count rate (NECR) of 1.27 kcps was achieved at 290 μCi (10.7 MBq). The system showed good imaging performance inside a 7-T animal MRI system; however improvements in data acquisition electronics and reduction of the coincidence timing window are needed to realize improved NECR performance.

Entities:  

Year:  2009        PMID: 21072320      PMCID: PMC2976049          DOI: 10.1109/TNS.2009.2015448

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  16 in total

1.  Performance evaluation of microPET: a high-resolution lutetium oxyorthosilicate PET scanner for animal imaging.

Authors:  A F Chatziioannou; S R Cherry; Y Shao; R W Silverman; K Meadors; T H Farquhar; M Pedarsani; M E Phelps
Journal:  J Nucl Med       Date:  1999-07       Impact factor: 10.057

2.  Resolution and noise properties of MAP reconstruction for fully 3-D PET.

Authors:  J Qi; R M Leahy
Journal:  IEEE Trans Med Imaging       Date:  2000-05       Impact factor: 10.048

3.  Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors.

Authors:  Martin S Judenhofer; Bernd J Pichler; Simon R Cherry
Journal:  Phys Med Biol       Date:  2005-01-07       Impact factor: 3.609

4.  GATE: a simulation toolkit for PET and SPECT.

Authors:  S Jan; G Santin; D Strul; S Staelens; K Assié; D Autret; S Avner; R Barbier; M Bardiès; P M Bloomfield; D Brasse; V Breton; P Bruyndonckx; I Buvat; A F Chatziioannou; Y Choi; Y H Chung; C Comtat; D Donnarieix; L Ferrer; S J Glick; C J Groiselle; D Guez; P F Honore; S Kerhoas-Cavata; A S Kirov; V Kohli; M Koole; M Krieguer; D J van der Laan; F Lamare; G Largeron; C Lartizien; D Lazaro; M C Maas; L Maigne; F Mayet; F Melot; C Merheb; E Pennacchio; J Perez; U Pietrzyk; F R Rannou; M Rey; D R Schaart; C R Schmidtlein; L Simon; T Y Song; J M Vieira; D Visvikis; R Van de Walle; E Wieërs; C Morel
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

5.  Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.

Authors:  Bernd J Pichler; Martin S Judenhofer; Ciprian Catana; Jeffrey H Walton; Manfred Kneilling; Robert E Nutt; Stefan B Siegel; Claus D Claussen; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-04       Impact factor: 10.057

6.  Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.

Authors:  Ciprian Catana; Yibao Wu; Martin S Judenhofer; Jinyi Qi; Bernd J Pichler; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-12       Impact factor: 10.057

7.  Design of field-cycled magnetic resonance systems for small animal imaging.

Authors:  K M Gilbert; W B Handler; T J Scholl; J W Odegaard; B A Chronik
Journal:  Phys Med Biol       Date:  2006-05-17       Impact factor: 3.609

8.  A New Positioning Algorithm for Position-Sensitive Avalanche Photodiodes.

Authors:  Jin Zhang; Peter D Olcott; Craig S Levin
Journal:  IEEE Trans Nucl Sci       Date:  2007-06-01       Impact factor: 1.679

9.  Simultaneous MRI and PET imaging of a rat brain.

Authors:  Raymond R Raylman; Stan Majewski; Susan K Lemieux; S Sendhil Velan; Brian Kross; Vladimir Popov; Mark F Smith; Andrew G Weisenberger; Carl Zorn; Gary D Marano
Journal:  Phys Med Biol       Date:  2006-11-23       Impact factor: 3.609

10.  Performance evaluation of the microPET R4 PET scanner for rodents.

Authors:  Christof Knoess; Stefan Siegel; Anne Smith; Danny Newport; Norbert Richerzhagen; Alexandra Winkeler; Andreas Jacobs; Rhonda N Goble; Rudolf Graf; Klaus Wienhard; Wolf-Dieter Heiss
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-01-21       Impact factor: 9.236

View more
  12 in total

1.  Quantitative, simultaneous PET/MRI for intratumoral imaging with an MRI-compatible PET scanner.

Authors:  Thomas S C Ng; James R Bading; Ryan Park; Hargun Sohi; Daniel Procissi; David Colcher; Peter S Conti; Simon R Cherry; Andrew A Raubitschek; Russell E Jacobs
Journal:  J Nucl Med       Date:  2012-06-01       Impact factor: 10.057

2.  Small animal, positron emission tomography-magnetic resonance imaging system based on a clinical magnetic resonance imaging scanner: evaluation of basic imaging performance.

Authors:  Raymond R Raylman; Patrick Ledden; Alexander V Stolin; Bob Hou; Ganghadar Jaliparthi; Peter F Martone
Journal:  J Med Imaging (Bellingham)       Date:  2018-09-08

3.  Performance evaluation of RF coils integrated with an RF-penetrable PET insert for simultaneous PET/MRI.

Authors:  Brian J Lee; Ronald D Watkins; Keum Sil Lee; Chen-Ming Chang; Craig S Levin
Journal:  Magn Reson Med       Date:  2018-09-09       Impact factor: 4.668

Review 4.  Advances in PET/MR instrumentation and image reconstruction.

Authors:  Jorge Cabello; Sibylle I Ziegler
Journal:  Br J Radiol       Date:  2016-07-22       Impact factor: 3.039

5.  After-pulsing, cross-talk, dark-count, and gain of MPPC under 7-T static magnetic field.

Authors:  Yoshiyuki Hirano; Fumihiko Nishikido; Daisuke Kokuryo; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2016-05-17

Review 6.  PET/MRI: Technical Challenges and Recent Advances.

Authors:  Jin Ho Jung; Yong Choi; Ki Chun Im
Journal:  Nucl Med Mol Imaging       Date:  2016-01-26

Review 7.  Standardization of Small Animal Imaging-Current Status and Future Prospects.

Authors:  Julia G Mannheim; Firat Kara; Janine Doorduin; Kerstin Fuchs; Gerald Reischl; Sayuan Liang; Marleen Verhoye; Felix Gremse; Laura Mezzanotte; Marc C Huisman
Journal:  Mol Imaging Biol       Date:  2018-10       Impact factor: 3.488

Review 8.  Positron emission tomography/MRI for cardiac diseases assessment.

Authors:  Osamu Manabe; Noriko Oyama-Manabe; Nagara Tamaki
Journal:  Br J Radiol       Date:  2020-02-14       Impact factor: 3.039

9.  An Advanced 100-Channel Readout System for Nuclear Imaging.

Authors:  Zhixiang Zhao; Siwei Xie; Xi Zhang; Jingwu Yang; Qiu Huang; Jianfeng Xu; Qiyu Peng
Journal:  IEEE Trans Instrum Meas       Date:  2018-11-15       Impact factor: 4.016

10.  Signal and noise properties of position-sensitive avalanche photodiodes.

Authors:  Yongfeng Yang; Yibao Wu; Richard Farrell; Purushottam A Dokhale; Kanai S Shah; Simon R Cherry
Journal:  Phys Med Biol       Date:  2011-09-06       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.