After-pulsing, cross-talk, dark-count, and gain of MPPC under 7-T static magnetic field.

Yoshiyuki Hirano1,2, Fumihiko Nishikido3, Daisuke Kokuryo3, Taiga Yamaya3.   

Abstract

Multi-pixel photon counters (MPPCs) have been used instead of photomultiplier tubes for positron emission tomography combined with magnetic resonance (PET-MR). However, the effects of the magnetic field (MF) on the intrinsic properties-gain, cross-talk, after-pulsing, and dark-count-have not been sufficiently investigated. Therefore, we measured these properties for two types of MPPCs-S10931-50P and S12572-50P-in a static 7-T MF. These properties were measured with a pulse-shape analysis using pulse data acquired by a digital oscilloscope in the presence of the MF (w/MF) and the absence of the MF (w/o MF) by changing the supplied over-voltages (from 0.95 to 2.1 V for S10931 and from 2.1 to 3.3 V for S12572). No significant differences between the w/MF and w/o MF cases were observed for either MPPC, suggesting that the gain, cross-talk, after-pulsing, and dark-count are insensitive to a 7-T MF. The present work shows that constant MPPC performance is expected under a strong MF and demonstrates positive results for PET-MR.

Keywords:  After-pulse; Cross-talk; Dark-count; MPPC; PET-MR

Mesh:

Year:  2016        PMID: 27188511     DOI: 10.1007/s12194-016-0356-3

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  23 in total

1.  SiPM-PET with a short optical fiber bundle for simultaneous PET-MR imaging.

Authors:  Seong Jong Hong; Han Gyoo Kang; Guen Bae Ko; In Chan Song; June-Tak Rhee; Jae Sung Lee
Journal:  Phys Med Biol       Date:  2012-05-30       Impact factor: 3.609

2.  PET Performance Evaluation of an MR-Compatible PET Insert.

Authors:  Yibao Wu; Ciprian Catana; Richard Farrell; Purushottam A Dokhale; Kanai S Shah; Jinyi Qi; Simon R Cherry
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-16       Impact factor: 1.679

3.  Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.

Authors:  Bernd J Pichler; Martin S Judenhofer; Ciprian Catana; Jeffrey H Walton; Manfred Kneilling; Robert E Nutt; Stefan B Siegel; Claus D Claussen; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-04       Impact factor: 10.057

4.  Hybrid PET/MR imaging of the heart: feasibility and initial results.

Authors:  Felix Nensa; Thorsten D Poeppel; Karsten Beiderwellen; Juliane Schelhorn; Amir A Mahabadi; Raimund Erbel; Philipp Heusch; Kai Nassenstein; Andreas Bockisch; Michael Forsting; Thomas Schlosser
Journal:  Radiology       Date:  2013-05-07       Impact factor: 11.105

5.  A temperature-dependent gain control system for improving the stability of Si-PM-based PET systems.

Authors:  Seiichi Yamamoto; Junkichi Satomi; Tadashi Watabe; Hiroshi Watabe; Yasukazu Kanai; Masao Imaizumi; Eku Shimosegawa; Jun Hatazawa
Journal:  Phys Med Biol       Date:  2011-04-08       Impact factor: 3.609

6.  Evaluation of Geiger-mode APDs for PET block detector designs.

Authors:  Armin Kolb; Eckart Lorenz; Martin S Judenhofer; Dieter Renker; Konrad Lankes; Bernd J Pichler
Journal:  Phys Med Biol       Date:  2010-03-05       Impact factor: 3.609

7.  Comparison of lesion detection and quantitation of tracer uptake between PET from a simultaneously acquiring whole-body PET/MR hybrid scanner and PET from PET/CT.

Authors:  Marco Wiesmüller; Harald H Quick; Bharath Navalpakkam; Michael M Lell; Michael Uder; Philipp Ritt; Daniela Schmidt; Michael Beck; Torsten Kuwert; Carl C von Gall
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-10-06       Impact factor: 9.236

8.  Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner.

Authors:  Gaspar Delso; Sebastian Fürst; Björn Jakoby; Ralf Ladebeck; Carl Ganter; Stephan G Nekolla; Markus Schwaiger; Sibylle I Ziegler
Journal:  J Nucl Med       Date:  2011-11-11       Impact factor: 10.057

9.  Evaluation of feasibility and image quality of 68Ga-DOTATOC positron emission tomography/magnetic resonance in comparison with positron emission tomography/computed tomography in patients with neuroendocrine tumors.

Authors:  Florian C Gaertner; Ambros J Beer; Michael Souvatzoglou; Matthias Eiber; Sebastian Fürst; Sybille I Ziegler; Florian Brohl; Markus Schwaiger; Klemens Scheidhauer
Journal:  Invest Radiol       Date:  2013-05       Impact factor: 6.016

10.  Whole-body PET/CT scanning: estimation of radiation dose and cancer risk.

Authors:  Bingsheng Huang; Martin Wai-Ming Law; Pek-Lan Khong
Journal:  Radiology       Date:  2009-02-27       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.