Literature DB >> 17148823

Simultaneous MRI and PET imaging of a rat brain.

Raymond R Raylman1, Stan Majewski, Susan K Lemieux, S Sendhil Velan, Brian Kross, Vladimir Popov, Mark F Smith, Andrew G Weisenberger, Carl Zorn, Gary D Marano.   

Abstract

Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI will allow the correlation of form with function. Our group is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode. Each MRI-PET detector module consists of an array of LSO detector elements coupled through a long fibre optic light guide to a single Hamamatsu flat panel position-sensitive photomultiplier tube (PSPMT). The use of light guides allows the PSPMTs to be positioned outside the bore of a 3T MRI scanner where the magnetic field is relatively small. To test the device, simultaneous MRI and PET images of the brain of a male Sprague Dawley rat injected with FDG were successfully obtained. The images revealed no noticeable artefacts in either image set. Future work includes the construction of a full ring PET scanner, improved light guides and construction of a specialized MRI coil to permit higher quality MRI imaging.

Entities:  

Mesh:

Year:  2006        PMID: 17148823     DOI: 10.1088/0031-9155/51/24/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  22 in total

1.  Small-animal molecular imaging methods.

Authors:  Robert A de Kemp; Frederick H Epstein; Ciprian Catana; Benjamin M W Tsui; Erik L Ritman
Journal:  J Nucl Med       Date:  2010-05-01       Impact factor: 10.057

2.  Assessment of MR compatibility of a PET insert developed for simultaneous multiparametric PET/MR imaging on an animal system operating at 7 T.

Authors:  Hans F Wehrl; Martin S Judenhofer; Axel Thielscher; Petros Martirosian; Fritz Schick; Bernd J Pichler
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

3.  PET Performance Evaluation of an MR-Compatible PET Insert.

Authors:  Yibao Wu; Ciprian Catana; Richard Farrell; Purushottam A Dokhale; Kanai S Shah; Jinyi Qi; Simon R Cherry
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-16       Impact factor: 1.679

4.  Simultaneous acquisition of magnetic resonance spectroscopy (MRS) data and positron emission tomography (PET) images with a prototype MR-compatible, small animal PET imager.

Authors:  Raymond R Raylman; Stan Majewski; S Sendhil Velan; Susan Lemieux; Brian Kross; Vladimir Popov; Mark F Smith; Andrew G Weisenberger
Journal:  J Magn Reson       Date:  2007-03-24       Impact factor: 2.229

Review 5.  PET/MRI hybrid imaging: devices and initial results.

Authors:  Bernd J Pichler; Martin S Judenhofer; Hans F Wehrl
Journal:  Eur Radiol       Date:  2008-03-21       Impact factor: 5.315

Review 6.  PET/MRI system design.

Authors:  Gaspar Delso; Sibylle Ziegler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

Review 7.  Pre-clinical PET/MR: technological advances and new perspectives in biomedical research.

Authors:  Hans F Wehrl; Martin S Judenhofer; Stefan Wiehr; Bernd J Pichler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

8.  Simultaneous imaging of magnetic resonance imaging and positron emission tomography by means of MRI-compatible optic fiber-based PET: a validation study in ex vivo rat brain.

Authors:  Masao Imaizumi; Seiichi Yamamoto; Makoto Kawakami; Masaaki Aoki; Eiji Sugiyama; Yasukazu Kanai; Eku Shimosegawa; Jun Hatazawa
Journal:  Jpn J Radiol       Date:  2009-07-22       Impact factor: 2.374

Review 9.  Positron emission tomography-magnetic resonance imaging: technical review.

Authors:  Raymond F Muzic; Frank P DiFilippo
Journal:  Semin Roentgenol       Date:  2014-10-18       Impact factor: 0.800

10.  Design, evaluation and initial imaging results of a PET insert based on strip-line readout for simultaneous PET/MRI.

Authors:  H Kim; Y Hua; H-T Chen; H-M Tsai; C-T Chen; G Karczmar; X Fan; D Xi; Q Xie; C-Y Chou; C-M Kao
Journal:  Nucl Instrum Methods Phys Res A       Date:  2020-02-05       Impact factor: 1.455

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.